Serum ethylene glycol by high-performance liquid chromatography

被引:18
|
作者
Vollmer, PA
Harty, DC
Erickson, NB
Balhon, AC
Dean, RA
机构
[1] INDIANA UNIV,SCH MED,DEPT PATHOL & LAB MED,INDIANAPOLIS,IN 46202
[2] INDIANA UNIV,SCH MED,DEPT BIOCHEM & MOL BIOL,INDIANAPOLIS,IN 46202
来源
关键词
ethylene glycol;
D O I
10.1016/S0378-4347(96)00173-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-performance liquid chromatography procedure for detection and quantitation of ethylene glycol in serum is described. Ethylene glycol and internal standard are derivatized with benzoyl chloride under alkaline conditions, purified by solid-phase extraction and analyzed by HPLC with UV detection. Analytical recovery of ethylene glycol ranges between 96 and 103%. The calibration curve is linear from 20 to 2000 mg/l. The limits of detection and quantitation are 10 and 20 mg/l, respectively. Assay imprecision is 4.8% or less. The assay is free from common interferences and provides increased sensitivity, improved precision and extended linearity.
引用
收藏
页码:370 / 374
页数:5
相关论文
共 50 条