The development of high-voltage repetitive low-jitter corona stabilized triggered switch

被引:21
|
作者
Geng, Jiuyuan [1 ]
Yang, Jianhua [1 ]
Cheng, Xinbing [1 ]
Yang, Xiao [1 ]
Chen, Rong [1 ]
机构
[1] Natl Univ Def Technol, Coll Optoelect Sci & Engn, Changsha 410073, Hunan, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2018年 / 89卷 / 04期
关键词
GAS-MIXTURES; IONIZATION; SF6; COEFFICIENTS; BREAKDOWN; FIELD; N-2;
D O I
10.1063/1.5011089
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The high-power switch plays an important part in a pulse power system. With the trend of pulse power technology toward modularization, miniaturization, and accuracy control, higher requirements on electrical trigger and jitter of the switch have been put forward. A high-power low-jitter corona-stabilized triggered switch (CSTS) is designed in this paper. This kind of CSTS is based on corona stabilized mechanism, and it can be used as a main switch of an intense electron-beam accelerator (IEBA). Its main feature was the use of an annular trigger electrode instead of a traditional needle-like trigger electrode, taking main and side trigger rings to fix the discharging channels and using SF6/N-2 gas mixture as its operation gas. In this paper, the strength of the local field enhancement was changed by a trigger electrode protrusion length Dp. The differences of self-breakdown voltage and its stability, delay time jitter, trigger requirements, and operation range of the switch were compared. Then the effect of different SF6/N-2 mixture ratio on switch performance was explored. The experimental results show that when the SF6 is 15% with the pressure of 0.2 MPa, the hold-off voltage of the switch is 551 kV, the operating range is 46.4%-93.5% of the self-breakdown voltage, the jitter is 0.57 ns, and the minimum trigger voltage requirement is 55.8% of the peak. At present, the CSTS has been successfully applied to an IEBA for long time operation. Published by AIP Publishing.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] STABILIZED HIGH-VOLTAGE SOURCE
    VOLKOV, VG
    SHTEIN, MM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1976, 19 (05) : 1449 - 1450
  • [42] STABILIZED HIGH-VOLTAGE CONVERTER
    PETIN, GP
    MARTIROSYAN, AA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1978, 21 (02) : 456 - 457
  • [43] HIGH-VOLTAGE MOS SWITCH
    SARASWAT, KC
    MEINDL, JD
    BERGER, J
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1975, SC10 (03) : 136 - 142
  • [44] HIGH-VOLTAGE NANOSECOND SWITCH
    MCDONALD, DF
    CUMMINGS, AJ
    WILSON, AR
    PROCEEDINGS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, 1965, 53 (11): : 1739 - &
  • [45] A simple high-voltage high current spark gap with subnanosecond jitter triggered by femtosecond laser filamentation
    Arantchouk, L.
    Houard, A.
    Brelet, Y.
    Carbonnel, J.
    Larour, J.
    Andre, Y. -B.
    Mysyrowicz, A.
    APPLIED PHYSICS LETTERS, 2013, 102 (16)
  • [46] High-voltage earthing switch
    Vostracky, Z.
    Sedlacek, J.
    PROCEEDINGS OF THE 10TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2009, 2009, : 324 - 327
  • [47] HIGH-VOLTAGE SWITCH PLANTS
    FLECK, B
    ELEKTROTECHNISCHE ZEITSCHRIFT B-AUSGABE, 1970, 22 (14): : 297 - &
  • [48] Optical and spectral techniques for studying high-voltage laser-triggered switch
    Shayganmanesh, Mahdi
    Mahdieh, Mohammad Hossein
    Goudarzi, Pegah Moazami
    Sinaki, Mohadese Maghrebi
    JOURNAL OF INSTRUMENTATION, 2024, 19 (10):
  • [49] RFID Performance in High-Voltage Corona
    Morys, Marcin M.
    Durgin, Gregory D.
    2012 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM (APSURSI), 2012,
  • [50] A Picosecond-jitter Electron-beam-triggered High-voltage Gas Spark Gap
    Yalandin, M. I.
    Sharypov, K. A.
    Shpak, V. G.
    Shunailov, S. A.
    Mesyats, G. A.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (01) : 34 - 38