Phase-shift Fizeau interferometer in presence of vibration

被引:0
|
作者
Doloca, Radu [1 ]
Broistedt, Hagen [1 ]
Tutsch, Rainer [1 ]
机构
[1] Tech Univ Carolo Wilhelmina Braunschweig, Inst Prod Messtech, D-38106 Braunschweig, Germany
来源
关键词
phase shifting interferometry; Fizeau interferometer; vibrations;
D O I
10.1117/12.794031
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In the context of this article we demonstrate a novel Fizeau interferometric system that copes with the presence of vibrations. Besides the conventional high spatial, but low temporal resolution detector system (the CCD camera) used in phase shifting interferometry, an additional high temporal, but low spatial resolution detector system was integrated, in order to measure the random phase shifts that are induced under the influence of the vibrations. The additional sensor consists of three photodiodes. The acquired analog signals enable the measurement of the occurring phase shifts at three non-collinear locations on the test surface. The resulting phase shifts at the three individual locations enable the determination of the random phase shifts over the entire image aperture. To avoid the smear phenomenon at very short exposure time, a beam shutter was integrated. Another alternative is to integrate a pulsed laser diode, for this purpose the concept of a wavelength meter is proposed. While the random oscillations of the test object are continuously measured, the CCD camera acquires several interferograms. In consequence, a phase shifting algorithm for random phase shifts was applied. In order to proof the validity of the new interferometer, a test surface of known topography was measured. The results of the measurements in presence of vibrations show very good concordance with the surface data given by the supplier. The analysis of the root mean square (RMS) over ten different measurement show a measurement repeatability of about 0.004 waves (approximately 2.5 nm for 632.8 nm laser wavelength).
引用
收藏
页数:12
相关论文
共 50 条
  • [11] Fizeau interferometers evaluated using FlashPhase and phase-shift fringe analysis
    Rabinovich, Emmanuel
    Carr, Barbara
    PHOTONICS SPECTRA, 2006, 40 (08) : 76 - 78
  • [12] Manufacturing and characterization of integrated optical phase-shift interferometer
    Hao Y.
    Ding J.
    Chen H.
    Jiang J.
    Meng H.
    Liu X.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2019, 48 (04):
  • [13] Instantaneous phase-shift, point-diffraction interferometer
    Millerd, JE
    Brock, NJ
    Hayes, JB
    Wyant, JC
    INTERFEROMETRY XII: TECHNIQUES AND ANALYSIS, 2004, 5531 : 264 - 272
  • [14] Wavelength Phase-shift Dual-diffraction Interferometer
    Jiang, Geng-An
    Lee, Ju-Yi
    SMART SCIENCE, 2014, 2 (03) : 139 - 143
  • [15] TOPOLOGICAL PHASE-SHIFT IN A COLD-ATOM INTERFEROMETER
    MULLER, JH
    BETTERMANN, D
    RIEGER, V
    SENGSTOCK, K
    STERR, U
    ERTMER, W
    APPLIED PHYSICS B-LASERS AND OPTICS, 1995, 60 (2-3): : 199 - 204
  • [16] STARK PHASE-SHIFT AND DEFLECTION IN THE ULTRACOLD ATOMIC INTERFEROMETER
    SHIMIZU, F
    SHIMIZU, K
    TAKUMA, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1992, 31 (4A): : L436 - L438
  • [17] Accurate phase measurement in phase-shift masks with a differential heterodyne interferometer
    Fujita, Hiroshi
    Miyashita, Hiroyuki
    Nakamura, Hiroyuki
    Sano, Hisatake
    Conference Record - IEEE Instrumentation and Measurement Technology Conference, 1994, 2 : 683 - 688
  • [18] Low coherence vibration insensitive fizeau interferometer
    Kimbrough, Brad
    Millerd, James
    Wyant, James
    Hayes, John
    INTERFEROMETRY XIII: TECHNIQUES AND ANALYSIS, 2006, 6292
  • [19] Instantaneous phase-shift, point-diffraction interferometer.
    Millerd, JE
    Martinek, SJ
    Brock, NJ
    Hayes, JB
    Wyant, JC
    OPTICAL DATA STORAGE 2004, 2004, 5380 : 422 - 429
  • [20] REFLECTION-TRANSMISSION PHASE-SHIFT - INTERFEROMETER AND VIEWING OPTICS
    MONJES, JA
    WEINSTEIN, BW
    WILLENBORG, DL
    APPLIED OPTICS, 1982, 21 (10): : 1732 - 1737