JPEG2000 3D compression vs 2D compression: An assessment of artifact amount and computing time in compressing thin-section abdomen CT images

被引:16
|
作者
Kim, Bohyoung [3 ]
Lee, Kyoung Ho [1 ,2 ]
Kim, Kil Joong [4 ]
Richter, Thomas [5 ]
Kang, Heung-Sik [1 ,2 ]
Kim, So Yeon [1 ,2 ]
Kim, Young Hoon [1 ,2 ]
Seo, Jinwook [3 ]
机构
[1] Seoul Natl Univ, Coll Med, Inst Radiat Med, Bundang Hosp,Dept Radiol, Songnam 463707, Gyeonggi Dol, South Korea
[2] Seoul Natl Univ, Med Res Ctr, Songnam 463707, Gyeonggi Dol, South Korea
[3] Seoul Natl Univ, Sch Engn & Comp Sci, Seoul 151744, South Korea
[4] Seoul Natl Univ, Coll Med, Dept Radiat Appl Life Sci, Seoul 110744, South Korea
[5] Univ Stuttgart, Ctr Informat Technol, D-70550 Stuttgart, Germany
关键词
computerised tomography; diagnostic radiography; image coding; medical image processing; VISUALLY LOSSLESS THRESHOLD; PERCEPTUAL QUALITY METRICS; ABDOMINAL CT; WAVELET COMPRESSION; MULTISLICE CT; RATIO; DIFFERENCE; PREDICTION; DATASETS; LUNG;
D O I
10.1118/1.3075824
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the advantages of the Joint Photographic Experts Group (JPEG)2000 3D (part 2) over JPEG2000 in compressing thin-section abdomen CT data sets, 60 thin-section (0.67 mm) scans from 35 males and 25 females, ranging from 23 to 95 years of age (mean, 58 years), were compressed reversibly (as a negative control) and irreversibly to 4:1, 6:1, 8:1, 10:1, and 12:1 using JPEG2000 3D and JPEG2000 algorithms. Encoding and decoding times and peak signal-to-noise ratios (PSNRs) were measured. For 60 (one image per scan) representative sections containing abnormalities, three radiologists independently compared original and compressed images and graded compression artifacts as 0 (none, indistinguishable), 1 (barely perceptible), 2 (subtle), or 3 (significant). According to pooled radiologists' responses, the range of visually lossless threshold (VLT, the highest compression ratio at which a compressed image is indistinguishable from its original) was determined as one of < 4:1, 4:1-6:1, 6:1-8:1, 8:1-10:1, 10:1-12:1, and >12:1. Wilcoxon signed rank tests and exact tests for paired proportions were used for the comparisons between the two compressions. At each irreversible compression ratio, compared to JPEG2000, JPEG2000 3D required two- or threefold greater computing times (p < 0.001) and introduced less artifacts in terms of PSNR (p < 0.001) and the grade (p < 0.02 at 6:1 or higher) and the presence of perceived artifacts (p < 0.008, at 6:1 for all readers and at 8:1 for two readers). According to PSNR and readers' responses, 6:1 and 8:1 JPEG2000 3D compressions showed more artifacts than 4:1 and 6:1 JPEG2000 compressions, respectively, and 10:1 and 12:1 JPEG2000 3D compressions showed similar artifacts to those of 8:1 and 10:1 JPEG2000 compressions, respectively. The determined VLT range was higher for JPEG2000 3D than for JPEG2000 (p < 0.001): the 3D compression showed the VLT ranges of 4:1-6:1, 6:1-8:1, and 8:1-10:1 for 24 (40%), 30 (50%), and 6 (10%) of the 60 original images, respectively, while the 2D compression showed the VLT ranges of < 4:1, 4:1-6:1, and 6:1-8:1 for 1 (1.7%), 40 (66.7%), and 19 (31.6%) images, respectively. Compared to JPEG2000, JPEG2000 3D increased the VLT range in 23 of the 60 original images by one (n=22) or two ranges (n=1), while the remaining 37 images had the same VLT range between the two compressions. In conclusion, compared to JPEG2000 compression, JPEG2000 3D compression yields less artifacts in compressing thin-section abdomen CT images but requires significantly greater computing times. For the tested data set compressed to the range from 4:1 to 12:1, JPEG2000 3D could increase compression level reasonably (by 2 or less in terms of compression ratio) compared to JPEG2000 for the same amount of artifacts.
引用
收藏
页码:835 / 844
页数:10
相关论文
共 33 条
  • [21] Functional assessment for the natural knee joints in squat activity by simulation of 2D X-ray images based on 3D CT images
    Shiraishi, Yoshitaka
    Shimoto, Takeshi
    Higaki, Hidehiko
    Nakanishi, Yoshitaka
    Tashiro, Yasutaka
    Miura, Hiromasa
    Iwamoto, Yukihide
    Hara, Toshiaki
    Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C, 2011, 77 (782): : 3761 - 3769
  • [22] Damage assessment of NCF, 2D and 3D woven composites under compression after multiple-impact using acoustic emission
    Saeedifar, Milad
    Saleh, Mohamed Nasr
    El-Dessouky, Hassan M.
    De Freitas, Sofia Teixeira
    Zarouchas, Dimitrios
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2020, 132
  • [23] Real-time respiratory phase matching between 2D fluoroscopic images and 3D CT images for precise percutaneous lung biopsy
    Weon, Chijun
    Kim, Mina
    Park, Chang Min
    Ra, Jong Beom
    MEDICAL PHYSICS, 2017, 44 (11) : 5824 - 5834
  • [24] 3D real time vs 2D transthoracic echocardiography in mitral regurgitation assessment before revascularisation after myocardial infarction
    Scislo, P.
    Kochanowski, J.
    Suwalski, P.
    Piatkowski, R.
    Kosior, D.
    EUROPEAN HEART JOURNAL, 2005, 26 : 540 - 541
  • [25] Compression CT urography: Comparison of 3D volume rendered images with IVP in evaluation of the collecting system and ureters, and assessment of clinical acceptabilty by urologists
    Heneghan, JP
    Kim, DH
    Howard, MH
    Leder, RA
    Delong, DM
    Nelson, RC
    RADIOLOGY, 1999, 213P : 475 - 475
  • [26] Could a 2D/3D US based model be helpful in the assessment of myometrial invasion at time of intraoperative frozen section? A pilot study
    Ferrero, Annamaria
    Novara, Lorenzo
    Perotto, Stefania
    Capece, Roberto
    Petey, Francesca
    Perrini, Gaetano
    Mariani, Luca L.
    de Rosa, Giovanni
    Biglia, Nicoletta
    Fuso, Luca
    MINERVA OBSTETRICS AND GYNECOLOGY, 2021, 73 (03) : 362 - 368
  • [27] 2D Manual vs 3D Automated Assessment of Alignment in Normal and Charcot-Marie-Tooth Cavovarus Feet Using Weightbearing CT
    Sangoi, Dhrumin
    Ranjit, Srinath
    Bernasconi, Alessio
    Cullen, Nicholas
    Patel, Shelain
    Welck, Matthew
    Malhotra, Karan
    FOOT & ANKLE INTERNATIONAL, 2022, 43 (07) : 973 - 982
  • [28] In vivo quantification of 3D displacement in sacral soft tissues under compression: Relevance of 2D US-based measurements for pressure ulcer risk assessment
    Mukhina, Ekaterina
    Trebbi, Alessio
    Rohan, Pierre-Yves
    Connesson, Nathanael
    Payan, Yohan
    JOURNAL OF TISSUE VIABILITY, 2022, 31 (04) : 593 - 600
  • [29] JPEG 2000 2D和3D可逆压缩薄层胸部CT影像:通过提高体外数据冗余增加其压缩性
    K.J.Kim
    K.H.Lee
    B.Kim
    T.Richter
    S.U.Lee
    赵芳
    国际医学放射学杂志, 2011, 34 (03) : 291 - 292
  • [30] Topographic Assessment of Periodontal Craters and Furcation Involvements by Using 2D Digital Images Versus 3D Cone Beam CT: an in-vitro Study
    Vandenberghe, Bart
    Jacobs, Reinhilde
    Yang, Jie
    CHINESE JOURNAL OF DENTAL RESEARCH, 2007, 10 (01): : 21 - 29