A statistical approach to the evaluation of covariate effects on the receiver operating characteristic curves of diagnostic tests in glaucoma

被引:67
|
作者
Medeiros, Felipe A.
Sample, Pamela A.
Zangwill, Linda M.
Liebmann, Jeffrey M.
Girkin, Christopher A.
Weinreb, Robert N.
机构
[1] Univ Calif San Diego, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Ophthalmol, La Jolla, CA 92093 USA
[3] New York Eye & Ear Infirm, New York, NY 10003 USA
[4] Univ Alabama Birmingham, Birmingham, AL USA
关键词
D O I
10.1167/iovs.05-1441
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To describe an approach for the evaluation of covariate effects on receiver operating characteristic (ROC) curves and to apply this methodology to the investigation of the effects of disease severity and age on the diagnostic performance of frequency doubling technology (17137) and standard automated perimetry (SAP) visual function tests for glaucoma detection. METHODS. The study included 370 eyes of 211 participants, with 174 eyes of I 10 patients having glaucomatous optic neuropathy and 196 eyes of 101 subjects being normal. All patients underwent visual function testing with FDT 24-2 Humphrey Matrix and SAP SITA (Carl Zeiss Meditec, Inc., Dublin, CA). Disease severity was evaluated by the amount of neuroretinal rim loss assessed by confocal scanning laser ophthalmoscopy. An ROC regression model was fitted to evaluate the influence of disease severity and age on the diagnostic performance of the pattern SD (PSD) index from FDT 24-2 and SAP SITA. RESULTS. After adjustment for age, the areas under the ROC curves (AUCs) for SAP SITA PSD for 10%, 30%, 50%, and 70% loss of neuroretinal rim area were 0.638, 0.756, 0.852, and 0.920, respectively. Corresponding values for FDT 24-2 PSD were 0.766, 0.857, 0.922, and 0.962. For 10% and 30% rim loss, FDT 24-2 PSD had a significantly larger AUC than did SAP SITA PSD. CONCLUSIONS. A regression methodology to evaluate covariate effects on ROC curves can be useful for assessment of diagnostic tests in glaucoma. Using the proposed methodology, a significantly better performance of FDT 24-2 compared to SAP SITA for diagnosis of early glaucoma was demonstrated.
引用
收藏
页码:2520 / 2527
页数:8
相关论文
共 50 条
  • [41] Analysing receiver operating characteristic curves with SAS
    Karagrigoriou, Alex
    JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES A-STATISTICS IN SOCIETY, 2008, 171 : 1036 - 1036
  • [42] THE USE OF RECEIVER OPERATING CHARACTERISTIC (ROC) CURVES
    MOISE, A
    SALAMON, R
    COMMENGES, D
    CLEMENT, B
    REVUE D EPIDEMIOLOGIE ET DE SANTE PUBLIQUE, 1986, 34 (03): : 209 - 217
  • [43] Risk assessment and receiver operating characteristic curves
    Szmukler, G.
    Everitt, B.
    Leese, M.
    PSYCHOLOGICAL MEDICINE, 2012, 42 (05) : 895 - 898
  • [44] Right receiver operating characteristic curves Reply
    Alhashemi, Jamal A.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2009, 27 (01): : 116 - 117
  • [45] CONFIDENCE BANDS FOR RECEIVER OPERATING CHARACTERISTIC CURVES
    MA, GQ
    HALL, WJ
    MEDICAL DECISION MAKING, 1993, 13 (03) : 191 - 197
  • [46] RECEIVER OPERATING CHARACTERISTIC CURVES FOR POISSON SIGNALS
    THIBOS, LN
    LEVICK, WR
    COHN, TE
    BIOLOGICAL CYBERNETICS, 1979, 33 (01) : 57 - 61
  • [47] Receiver operating characteristic curves and their use in radiology
    Obuchowski, NA
    RADIOLOGY, 2003, 229 (01) : 3 - 8
  • [48] Peirce, Youden, and receiver operating characteristic curves
    Baker, Stuart G.
    Kramer, Barnett S.
    AMERICAN STATISTICIAN, 2007, 61 (04): : 343 - 346
  • [49] A Boolean algebra of Receiver Operating Characteristic curves
    Oxley, Mark E.
    Thorsen, Steven N.
    Schubert, Christine M.
    2007 PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INFORMATION FUSION, VOLS 1-4, 2007, : 1391 - +
  • [50] Estimation and comparison of receiver operating characteristic curves
    Pepe, Margaret S.
    Longton, Gary
    Janes, Holly
    STATA JOURNAL, 2009, 9 (01): : 1 - 16