CCD and offset after Nanos short stem in total hip arthroplasty

被引:13
|
作者
Ettinger, M. [1 ]
Ettinger, P. [2 ]
Ezechieli, M. [1 ]
Bueermann, S. [1 ]
Budde, S. [1 ]
Calliess, T. [1 ]
Petri, M. [4 ]
Thorey, F. [3 ]
机构
[1] Hannover Med Sch, Dept Orthopaed Surg, D-30625 Hannover, Germany
[2] Melle Christian Clin, Dept Orthopaed Surg, Melle, Germany
[3] ATOS Hosp Heidelberg, Ctr Hip Knee & Foot Surg, Heidelberg, Germany
[4] Hannover Med Sch, Dept Traumatol, D-30625 Hannover, Germany
关键词
Short hip stem; Nanos; total hip arthrosplasty; radiology; FEMORAL COMPONENT; REPLACEMENT; PROSTHESIS;
D O I
10.3233/THC-130716
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: Many short stems for total hip arthroplasty have been introduced by the manufacturers only during the last decade. One of them is the Nanos short stem (Smith and Nephew, Marl, Germany). The development of short stems was aimed at preserving bone and soft tissue by utilizing a minimally invasive approach, thus allowing a quick return to an active life. It was purpose of this study to evaluate the radiological changes after using this device. METHODS: We present the radiological results of 202 cementless THAs which were performed in 172 patients using the Nanos stem. Radiological evaluation was performed using standing anterior-posterior (AP) and lateral radiographs of the proximal femur preoperatively, postoperatively and during the follow up. We analyzed the preoperative and postoperativ CCD angle, the subsisdence, preoperative and postoperative offset, osteolysis, bone resorption, increased density, neocortex and periarthricular ossifications. RESULTS: One stem had to be revised due to subsidence four days after implantation. Two cups (BiconPlus, Smith and Nephew, Marl, Germany) had to be revised during the time of follow up due to an aseptic cup loosening. Two stems showed radiolucent lines at the implant-bone-interface at the last follow-up. An increase of bone density could be detected in 18 hips (8.9%). 14 hips showed periarticular ossifications. Measurable subsidence was detected in a total of four stems (1.9%). The preoperative neck-shaft-angle angle was 133.8 +/- 4.4 degrees(range: 118.5-146.2) and the neck-shaft-angle angle at the time of follow up was 134.6 +/- 4.3 degrees (range: 123.3-147; P < 0.05). The preoperative and postoperative offset changed from 109.3 +/- 11.9 mm (range: 80.9-131.6) to 109.7 +/- 12.3 mm (range: 79.7-155.6; P < 0.05). CONCLUSION: In summary, this study shows that a correct anatomical reconstruction is possible with a device of this design. The outcome is comparable to that of other short stems. Further studies should be performed in a prospective and randomized design to evaluate the advantage of such a device with a higher level of evidence.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [1] The NANOS short stem in total hip arthroplasty: a mid term follow-up
    Ettinger, Max
    Ettinger, Peter
    Lerch, Matthias
    Radtke, Kerstin
    Budde, Stefan
    Ezechieli, Marco
    Becher, Christoph
    Thorey, Fritz
    [J]. HIP INTERNATIONAL, 2011, 21 (05) : 583 - 586
  • [2] The Influence of Hip Rotation on Femoral Offset Following Short Stem Total Hip Arthroplasty
    Boese, Christoph K.
    Bredow, Jan
    Ettinger, Max
    Eysel, Peer
    Thorey, Fritz
    Lechler, Philipp
    Budde, Stefan
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (01): : 312 - 316
  • [3] Reproducibility of Femoral Offset Following Short Stem and Straight Stem Total Hip Arthroplasty
    von Roth, Philipp
    Perka, Carsten
    Mayr, Hermann O.
    Preininger, Bernd
    Ziebula, Friedrich
    Matziolis, Georg
    Hube, Robert
    [J]. ORTHOPEDICS, 2014, 37 (07) : E678 - E684
  • [4] Femoroacetabular offset restoration in total hip arthroplasty; Digital templating a short stem vs a conventional stem
    de Waard, Sheryl
    Verboom, Tom
    Bech, Niels Hendrik
    Sierevelt, Inger N.
    Kerkhoffs, Gino M.
    Haverkamp, Daniel
    [J]. WORLD JOURNAL OF ORTHOPEDICS, 2022, 13 (02): : 139 - 149
  • [5] Return to Sport After Short-Stem Total Hip Arthroplasty
    Ortmaier, Reinhold
    Pichler, Hannes
    Hitzl, Wolfgang
    Emmanuel, Katja
    Mattiassich, Georg
    Plachel, Fabian
    Hochreiter, Josef
    [J]. CLINICAL JOURNAL OF SPORT MEDICINE, 2019, 29 (06): : 451 - 458
  • [6] Restoring femoral offset and leg length; the potential of a short curved stem in total hip arthroplasty
    Snijders, Thom E.
    van Erp, Joost H. J.
    de Gast, Arthur
    [J]. JOURNAL OF ORTHOPAEDICS, 2019, 16 (05) : 396 - 399
  • [7] Is there a Bone-Preserving Bone Remodelling in Short-Stem Prosthesis? DEXA Analysis with the Nanos® Total Hip Arthroplasty
    Goetze, C.
    Ehrenbrink, J.
    Ehrenbrink, H.
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2010, 148 (04): : 398 - 405
  • [8] Migration characteristics and early clinical results of the NANOS® short-stem hip arthroplasty
    Kaipel, Martin
    Grabowiecki, Phillip
    Sinz, Katrina
    Farr, Sebastian
    Sinz, Guenter
    [J]. WIENER KLINISCHE WOCHENSCHRIFT, 2015, 127 (9-10) : 375 - 378
  • [9] Migration characteristics and early clinical results of the NANOS® short-stem hip arthroplasty
    Martin Kaipel
    Phillip Grabowiecki
    Katrina Sinz
    Sebastian Farr
    Günter Sinz
    [J]. Wiener klinische Wochenschrift, 2015, 127 : 375 - 378
  • [10] Radiological short term results after total hip arthroplasty using the Fitmore® hip stem
    Wanner, Ronald
    Notzli, Hubert
    Wyss, Tobias
    Miozzari, Hermes
    [J]. SWISS MEDICAL WEEKLY, 2013, 143 : 30S - 30S