Restoring femoral offset and leg length; the potential of a short curved stem in total hip arthroplasty

被引:14
|
作者
Snijders, Thom E. [1 ]
van Erp, Joost H. J. [1 ,2 ]
de Gast, Arthur [1 ,2 ]
机构
[1] Diakonessenhuis Zeist, Clin Orthoped Res Ctr mN, Prof Lorentzlaan 76, NL-3707 HL Zeist, Netherlands
[2] Diakonessen Hosp, Dept Orthopaed Surg, Utrecht, Netherlands
关键词
Total hip arthroplasty; Femoral offset; Leg length; Prosthesis design; Template; Short straight stem; ABDUCTOR MUSCLE STRENGTH;
D O I
10.1016/j.jor.2019.04.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Total hip arthroplasty (THA) is a very successful procedure in orthopedics. Still polyethylene wear and gait deficits are limiting the clinical success. It is important to reconstruct leg length (LL) and femoral offset (FO) anatomically in order to have the best possible result of a THA. Gait deficits can arise due to leg length discrepancy as well as changes in the abductor moment arm. In THA, LL and FO are strongly determined by the orientation, size and geometry of the femoral stem. Methods: This radio-anatomical study used the data of a prospective cases series of 112 patients who underwent 126 primary THAs and had completed a 1-year follow-up examination. FO and LL were compared between the conventional straight stem in vivo and a computed simulated implantation of a short curved stem, using the pre-and postoperative pelvic radiographs of the same patients. Results: In this simulation of the short curved stem statistically significantly restored native FO (p = 0.010) and LL (p = 0.000) better, compared to the conventional straight stem. Conclusions: Thus, the short curved stem restores FO and LL better, and could potentially prevent gait deficits.
引用
收藏
页码:396 / 399
页数:4
相关论文
共 50 条
  • [1] Accuracy of the Horizontal Calibrator in Correcting Leg Length and Restoring Femoral Offset in Total Hip Arthroplasty
    Chen, Xing
    Xing, Shuxing
    Zhu, Zhiyong
    Wang, Huisheng
    Yu, Zhongshen
    Bai, Xizhuang
    Li, Xi
    [J]. FRONTIERS IN SURGERY, 2022, 9
  • [2] LIGAMENT PRESERVING TOTAL HIP ARTHROPLASTY PREVENTS DIFFERENT LEG LENGTH AND FEMORAL OFFSET
    Fujita, Masahiro
    Hayashi, Shinya
    Kamenaga, Tomoyuki
    Fujishiro, Takaaki
    Matsumoto, Tomoyuki
    Kuroda, Ryosuke
    [J]. ACTA ORTOPEDICA BRASILEIRA, 2022, 30
  • [3] The Influence of Hip Rotation on Femoral Offset Following Short Stem Total Hip Arthroplasty
    Boese, Christoph K.
    Bredow, Jan
    Ettinger, Max
    Eysel, Peer
    Thorey, Fritz
    Lechler, Philipp
    Budde, Stefan
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (01): : 312 - 316
  • [4] Accuracy of the Horizontal Calibrator in Correcting Leg Length and Restoring Femoral Offset in Total Hip Arthroplasty (vol 9, 845364, 2022)
    Chen, Xing
    Xing, Shuxing
    Zhu, Zhiyong
    Wang, Huisheng
    Yu, Zhongshen
    Bai, Xizhuang
    Li, Xi
    [J]. FRONTIERS IN SURGERY, 2022, 9
  • [5] Reproducibility of Femoral Offset Following Short Stem and Straight Stem Total Hip Arthroplasty
    von Roth, Philipp
    Perka, Carsten
    Mayr, Hermann O.
    Preininger, Bernd
    Ziebula, Friedrich
    Matziolis, Georg
    Hube, Robert
    [J]. ORTHOPEDICS, 2014, 37 (07) : E678 - E684
  • [6] Optimizing the Femoral Offset for Restoring Physiological Hip Muscle Function in Patients With Total Hip Arthroplasty
    Hu, Xiangjun
    Zheng, Nan
    Chen, Yunsu
    Dai, Kerong
    Dimitriou, Dimitris
    Li, Huiwu
    Tsai, Tsung-Yuan
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [7] RESTORING THE FEMORAL OFFSET PREVENT EARLY MIGRATION OF THE STEM IN TOTAL HIP ARTHROPLASTY: AN EBRA-FCA STUDY
    Vicenti, G.
    Solarino, G.
    Spinarelli, A.
    Carrozzo, M.
    Picca, G.
    Maddalena, R.
    Rifino, F.
    Moretti, B.
    [J]. JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2016, 30 (04): : 207 - 212
  • [8] Are leg length and hip offset comparable after hip resurfacing and cementless total hip arthroplasty?
    Patel, S.
    Thakrar, R. R.
    Bhamra, J.
    Hossain, F.
    Tengrootenhuysen, M.
    Haddad, F. S.
    [J]. ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2011, 93 (06) : 465 - 469
  • [9] Accuracy of leg length and femoral offset restoration after total hip arthroplasty with the utilisation of an intraoperative calibration gauge
    Enke, Oliver
    Levy, Yadin D.
    Bruce, Warwick J. M.
    [J]. HIP INTERNATIONAL, 2020, 30 (03) : 296 - 302
  • [10] Effect of longer femoral head on leg length, offset, and range of motion in total hip arthroplasty: a simulation study
    Tomohiro Shimizu
    Takuji Miyazaki
    Shunichi Yokota
    Hotaka Ishizu
    Daisuke Takahashi
    Norimasa Iwasaki
    [J]. Scientific Reports, 14