Damping behavior of implant-supported restorations

被引:68
|
作者
Magne, Pascal [1 ]
Silva, Michael
Oderich, Elisa [2 ]
Boff, Luis Leonildo [3 ]
Enciso, Reyes [4 ]
机构
[1] Univ So Calif, Div Restorat Sci, Herman Ostrow Sch Dent, Los Angeles, CA 90089 USA
[2] Univ Fed Santa Catarina, Dept Dent, Florianopolis, SC, Brazil
[3] Univ Fed Santa Catarina, Dept Dent, Florianopolis, SC, Brazil
[4] Univ So Calif, Div Dent Publ Hlth & Pediat Dent, Herman Ostrow Sch Dent, Los Angeles, CA 90089 USA
关键词
adhesion; CAD; CAM; composite resin; dental implant; dynamic load response; implant abutment; percussion; porcelain; probe; zirconia; ENDODONTICALLY TREATED MOLARS; CRESTAL BONE LEVELS; FATIGUE RESISTANCE; COMPOSITE RESIN; DENTAL IMPLANTS; PORCELAIN VENEERS; FAILURE MODE; STRENGTH; SURFACE; ABUTMENTS;
D O I
10.1111/j.1600-0501.2011.02311.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The aim of the present study was to assess the shock absorbing capacity of implant-supported restorations (CAD/CAM composite resin or zirconia abutment with composite resin or porcelain crown/onlay) and a simulated natural tooth complex using the Periometer (R). Material and methods One hundred and twenty Morse taper implants (Titamax CM 11 mm) were mounted on bone-simulating acrylic resin base and restored with CAD/CAM zirconia (60) and metal composite resin Paradigm MZ100 (60) abutments. Using CEREC3, standardized onlays (60) and crowns (60) were designed and milled in ceramic (Paradigm C) or composite resin (Paradigm MZ100) to simulate a maxillary premolar. All restorations were luted with a preheated light curing composite resin (Filtek Z100). Fifteen extracted human upper premolars were mounted with a simulated PDL and used as control group. The Periometer (R), a new handheld percussion probe that measures the energy loss coefficient (LC) for both natural teeth and implant-supported structures, was positioned perpendicularly to the buccal surface of each restoration. Three measurements of the LC were collected for each specimen. The effect of each variable (abutment material, restoration material, and restoration design) on the LC was explored using multiple regression analysis. Results Differences in LC between the abutment material (zirconia/Paradigm MZ100), the restoration material (Paradigm C/Paradigm MZ100) and the restoration design (onlay/crown) were recorded. The average LC of zirconia and metal composite resin abutments ranged from 0.040 to 0.053 and 0.059 to 0.068, respectively. Zirconia abutments restored with composite resin restorations (LC 0.051-0.053) had the closest LC value when compared with teeth with simulated PDL (0.049). Conclusion Composite resin onlays/crowns bonded to zirconia implant abutments presented similar dynamic response to load (damping behavior) when compared to teeth with a simulated PDL.
引用
收藏
页码:143 / 148
页数:6
相关论文
共 50 条
  • [41] COMPLICATIONS OF THE IMPLANT-SUPPORTED POSTERIOR MANDIBULAR SINGLE RESTORATIONS WITH MESIAL CANTILEVER
    Shin, He Sung
    Kim, Myung-Rae
    Kim, Sun-Jong
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2009, 35 (04) : 248 - 252
  • [42] Fracture behavior of all-ceramic, implant-supported, and tooth–implant-supported fixed dental prostheses
    Abdul Rahman Alkharrat
    Marc Schmitter
    Stefan Rues
    Peter Rammelsberg
    Clinical Oral Investigations, 2018, 22 : 1663 - 1673
  • [43] Clinical Factors Influencing Removal of the Cement Excess in Implant-Supported Restorations
    Vindasiute, Egle
    Puisys, Algirdas
    Maslova, Natalja
    Linkeviciene, Laura
    Peciuliene, Vytaute
    Linkevicius, Tomas
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (04) : 771 - 778
  • [44] The Abutment Duplication Technique: A Novel Protocol for Cementable Implant-Supported Restorations
    Cocchetto, Roberto
    Resch, Ingrid
    Castagna, Marco
    Vincenzi, Giampaolo
    Celletti, Renato
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2010, 30 (04) : 415 - 424
  • [45] Maxillary sinus lift for single implant-supported restorations:: A clinical study
    Krennmair, Gerald
    Krainhoefner, Martin
    Schmid-Schwap, Martina
    Piehslinger, Eva
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (03) : 351 - 358
  • [46] Evaluation of the structural behavior of three and four implant-supported fixed prosthetic restorations by finite element analysis
    Correa, Santiago
    Ivancik, Juliana
    Isaza, Juan Felipe
    Naranjo, Mauricio
    JOURNAL OF PROSTHODONTIC RESEARCH, 2012, 56 (02) : 110 - 119
  • [47] Strain Development of Screw-Retained Implant-Supported Fixed Restorations: Procera Implant Bridge Versus Conventionally Cast Restorations
    Karl, Matthias
    Holst, Stefan
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (02) : 166 - 169
  • [48] Digital scanning for complete-arch implant-supported restorations: A systematic review
    Wulfman, Claudine
    Naveau, Adrien
    Rignon-Bret, Christophe
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (02): : 161 - 167
  • [49] The Effect of Different Surface Treatments on Cement-Retained Implant-Supported Restorations
    Kurt, Murat
    Kulunk, Tolga
    Ural, Cagri
    Kulunk, Safak
    Danisman, Sengul
    Savas, Soner
    JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (01) : 44 - 51
  • [50] Strain gage evaluation of two implant-supported loaded provisional restorations.
    Ross, J
    Breeding, LC
    Dixon, DL
    Barget, DZ
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 1315 - 1315