Energy resolution improvement of NaI(Tl) scintillation detectors by means of a timing discrimination method

被引:1
|
作者
Celiktas, C. [1 ]
Ermis, E. E. [1 ]
Bayburt, M. [2 ]
机构
[1] Ege Univ, Dept Phys, Fac Sci, TR-35100 Izmir, Turkey
[2] Ege Univ, Inst Nucl Sci, TR-35100 Izmir, Turkey
关键词
Constant fraction timing method; NaI(Tl) inorganic scintillation detector; Cs-137;
D O I
10.1007/s10967-012-1678-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gamma-ray energy spectrum of a Cs-137 radioisotope was obtained by using a NaI(Tl) scintillation detector. Improvement of the energy resolution of the detector was aimed. To achieve this, constant fraction timing method was used. Energy resolution of the photopeak of the isotope was improved from 7.1 to 6.7% through the timing application.
引用
下载
收藏
页码:377 / 382
页数:6
相关论文
共 50 条
  • [41] Energy resolution of scintillation detectors with SiPM light readout
    Grodzicka, M.
    Moszynski, M.
    Szczesniak, T.
    Kapusta, M.
    Szawlowski, M.
    Wolski, D.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1940 - 1948
  • [42] Determination of energy resolution for a NaI(Tl) detector modeled with FLUKA code
    Demir, Nilgun
    Kuluozturk, Zehra Nur
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (11) : 3759 - 3763
  • [43] A New Temperature Correction Method for NaI(Tl) Detectors Based on Pulse Deconvolution
    Xie, Jianming
    Yang, Liu
    Li, Jinglun
    Qi, Sheng
    Chen, Wenzhuo
    Xu, Hang
    Xiao, Wuyun
    SENSORS, 2023, 23 (11)
  • [44] NEW METHOD FOR MEASURING THE STATISTICAL RESOLUTION OF SCINTILLATION DETECTORS
    MURAYAMA, H
    TANAKA, E
    NOHARA, N
    NUCLEAR INSTRUMENTS & METHODS, 1979, 164 (03): : 447 - 451
  • [45] Mathematical method for optimal digitization and discrimination of scintillation detectors' pulses
    Saleh, H. I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 802 : 16 - 25
  • [46] Spectrum-dose conversion operator of NaI(Tl) and CsI(Tl) scintillation detectors for air dose rate measurement in contaminated environments
    Tsuda, Shuichi
    Saito, Kimiaki
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2017, 166 : 419 - 426
  • [47] Validation of measurement comparability of NaI(Tl) scintillation detectors for radioactive cesium in brown rice sample by interlaboratory comparison
    Tsutomu Miura
    Mayumi Hachinohe
    Akira Yunoki
    Shioka Hamamatsu
    Yasuhiro Unno
    Journal of Radioanalytical and Nuclear Chemistry, 2020, 326 : 1225 - 1231
  • [48] GAIN VS TEMPERATURE EFFECTS IN NAI(TL) PHOTOMULTIPLIER SCINTILLATION DETECTORS USING 10 AND 14 STAGE TUBES
    ROHDE, RE
    NUCLEAR INSTRUMENTS & METHODS, 1965, 34 (01): : 109 - &
  • [49] Multilayer passive shielding of scintillation detectors based on BGO, NaI(Tl), and stilbene crystals operating in intense neutron fields with an energy of 14.1 MeV
    Bystritsky V.M.
    Valkovic V.
    Grozdanov D.N.
    Zontikov A.O.
    Ivanov I.Z.
    Kopatch Y.N.
    Krylov A.R.
    Rogov Y.N.
    Ruskov I.N.
    Sapozhnikov M.G.
    Skoy V.R.
    Shvetsov V.N.
    Physics of Particles and Nuclei Letters, 2015, 12 (2) : 325 - 335
  • [50] Validation of measurement comparability of NaI(Tl) scintillation detectors for radioactive cesium in brown rice sample by interlaboratory comparison
    Miura, Tsutomu
    Hachinohe, Mayumi
    Yunoki, Akira
    Hamamatsu, Shioka
    Unno, Yasuhiro
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2020, 326 (02) : 1225 - 1231