Optimal microscopic systems for long-term imaging of intracellular calcium using a ratiometric genetically-encoded calcium indicator

被引:4
|
作者
Miyamoto, Akitoshi [1 ,2 ]
Bannai, Hiroko [1 ]
Michikawa, Takayuki [1 ,3 ,4 ]
Mikoshiba, Katsuhiko [1 ,5 ,6 ]
机构
[1] RIKEN, Dev Neurobiol Lab, Brain Sci Inst, Wako, Saitama 3510198, Japan
[2] Univ Tokyo, Inst Med Sci, Dept Basic Med Sci, Div Neuronal Network,Minato Ku, Tokyo 1088639, Japan
[3] Saitama Univ, Brain Sci Inst, Sakura Ku, Saitama 3388570, Japan
[4] RIKEN, Brain Sci Inst, Lab Behav Genet, Wako, Saitama 3510198, Japan
[5] Japan Sci & Technol Agcy, Calcium Oscillat Project, Int Cooperat Res Project, Kawaguchi, Saitama 3320012, Japan
[6] Japan Sci & Technol Agcy, Solut Oriented Res Sci & Technol, Kawaguchi, Saitama 3320012, Japan
关键词
Genetically encoded Ca2+ indicators; Illumination power; Ca2+ oscillation; Wide-field fluorescent microscope; Multipoint scanning confocal system; Single-point scanning confocal system; FLUORESCENT INDICATORS; GENE-EXPRESSION; CA2+; RECEPTOR; LYMPHOCYTES; MODULATION; PROTEINS; CHANNEL;
D O I
10.1016/j.bbrc.2013.02.112
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Monitoring the pattern of intracellular Ca2+ signals that control many diverse cellular processes is essential for understanding regulatory mechanisms of cellular functions. Various genetically encoded Ca2+ indicators (GECIs) are used for monitoring intracellular Ca2+ changes under several types of microscope systems. However, it has not yet been explored which microscopic system is ideal for long-term imaging of the spatiotemporal patterns of Ca2+ signals using GECIs. We here compared the Ca2+ signals reported by a fluorescence resonance energy transfer (FRET)-based ratiometric GECI, yellow cameleon 3.60 (YC3.60), stably expressed in DT40 B lymphocytes, using three different imaging systems. These systems included a wide-field fluorescent microscope, a multipoint scanning confocal system, and a single-point scanning confocal system. The degree of photobleaching and the signal-to-noise ratio of YC3.60 in DT40 cells were highly dependent on the fluorescence excitation method, although the total illumination energy was maintained at a constant level within each of the imaging systems. More strikingly, the Ca2+ responses evoked by B-cell antigen receptor stimulation in YC3.60-expressing DT40 cells were different among the imaging systems, and markedly affected by the illumination power used. Our results suggest that optimization of the imaging system, including illumination and acquisition conditions, is crucial for accurate visualization of intracellular Ca2+ signals. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:252 / 257
页数:6
相关论文
共 50 条
  • [21] A genetically encoded calcium indicator for chronic in vivo two-photon imaging
    Mank M.
    Santos A.F.
    Direnberger S.
    Mrsic-Flogel T.D.
    Hofer S.B.
    Stein V.
    Hendel T.
    Reiff D.F.
    Levelt C.
    Borst A.
    Bonhoeffer T.
    Hübener M.
    Griesbeck O.
    Nature Methods, 2008, 5 (9) : 805 - 811
  • [22] Live-cell imaging of rapid calcium dynamics using fluorescent, genetically-encoded GCaMP probes with Aspergillus fumigatus
    Munoz, Alberto
    Bertuzzi, Margherita
    Seidel, Constanze
    Thomson, Darren
    Bignell, Elaine M.
    Read, Nick D.
    FUNGAL GENETICS AND BIOLOGY, 2021, 151
  • [23] Visualization of the biphasic calcium wave during fertilization in Caenorhabditis elegans using a genetically encoded calcium indicator
    Toperzer, Katie M.
    Brennan, Savannah J.
    Carroll, David J.
    Guisbert, Eric A.
    Guisbert, Karen S. Kim
    BIOLOGY OPEN, 2023, 12 (09):
  • [24] A novel Ca2+ indicator for long-term tracking of intracellular calcium flux
    Liao, Jinfang
    Patel, Deven
    Zhao, Qin
    Peng, Ruogu
    Guo, Haitao
    Diwu, Zhenjun
    BIOTECHNIQUES, 2021, 70 (05)
  • [25] Two-Photon Imaging of Electrical Activity in Mouse Cortex using a Genetically-Encoded Voltage Indicator
    Akemann, Walther
    Mutoh, Hiroki
    Knoepfel, Thomas
    BIOPHYSICAL JOURNAL, 2013, 104 (02) : 336A - 336A
  • [26] Improved Long-Term Imaging of Embryos with Genetically Encoded α-Bungarotoxin
    Swinburne, Ian A.
    Mosaliganti, Kishore R.
    Green, Amelia A.
    Megason, Sean G.
    PLOS ONE, 2015, 10 (08):
  • [27] Auto-luminescent genetically-encoded ratiometric indicator for real-time Ca2+ imaging at the single cell level
    Saito, Kenta
    Kobayashi, Kentaro
    Nagai, Takeharu
    SMART NANO-MICRO MATERIALS AND DEVICES, 2011, 8204
  • [28] Auto-Luminescent Genetically-Encoded Ratiometric Indicator for Real-Time Ca2+ Imaging at the Single Cell Level
    Saito, Kenta
    Hatsugai, Noriyuki
    Horikawa, Kazuki
    Kobayashi, Kentaro
    Matsu-ura, Toru
    Mikoshiba, Katsuhiko
    Nagai, Takeharu
    PLOS ONE, 2010, 5 (03):
  • [29] Imaging calcium and redox signals using genetically encoded fluorescent indicators
    Gibhardta, Christine S.
    Zimmermann, Katharina M.
    Zhang, Xin
    Belousov, Vsevolod V.
    Bogeski, Ivan
    CELL CALCIUM, 2016, 60 (02) : 55 - 64
  • [30] Optogenetic Measurement of Presynaptic Calcium Transients Using Conditional Genetically Encoded Calcium Indicator Expression in Dopaminergic Neurons
    Sgobio, Carmelo
    Kupferschmidt, David A.
    Cui, Guohong
    Sun, Lixin
    Li, Zheng
    Cai, Huaibin
    Lovinger, David M.
    PLOS ONE, 2014, 9 (10):