Failure of MV Cable Terminations Due to Supraharmonic Voltages: A Risk Indicator

被引:14
|
作者
Espin-Delgado, Angela [1 ]
Letha, Shimi Sudha [1 ]
Ronnberg, Sarah K. [1 ]
Bollen, Math H. J. [1 ]
机构
[1] Lulea Univ Technol, Elect Power Engn Grp, S-97187 Skelleftea, Sweden
关键词
Dielectric breakdown; dielectric losses; power cable insulation; power quality; power system harmonics; supraharmonics;
D O I
10.1109/OJIA.2020.2998000
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper addresses the accelerated aging of medium-voltage (MV) cable terminations with resistive stress-grading due to supraharmonics. The paper introduces a simple and quick way to relate the risk of cable termination failure to the characteristics of supraharmonic distortion in the system. The motivation is to give practical recommendations and guidelines to evaluate the risk of failure of cable terminations under the presence of supraharmonics in MV networks. The underlying model relates the heating in the cable termination linearly with the frequency of the voltage applied and proportionally with the square of the magnitude of the voltage. The indicator can be used to decide whether given levels and frequencies of supraharmonics in the MV network represent a risk to cable terminations. The parameters of the cable termination design are not needed for that decision. However, the decision criterion is based on one sample data (Eagle Pass) and more field information is crucial to improve the approach.
引用
收藏
页码:42 / 51
页数:10
相关论文
共 50 条
  • [21] DETERMINATION OF THRESHOLD FAILURE LEVELS OF SEMICONDUCTOR DIODES AND TRANSISTORS DUE TO PULSE VOLTAGES
    WUNSCH, DC
    BELL, RR
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1968, NS15 (06) : 244 - +
  • [22] ANALYSIS OF PROGRESSIVE COLLAPSE IN CABLE-STAYED BRIDGES DUE TO CABLE FAILURE DURING EARTHQUAKE
    Fatollahzadeh, Amir
    Naghipour, Morteza
    Abdollahzadeh, Gholamreza
    [J]. INTERNATIONAL JOURNAL OF BRIDGE ENGINEERING, 2016, 4 (02): : 63 - 72
  • [23] MATHEMATICAL STUDY OF VOLTAGES BETWEEN SHEATH AND CABLE CONDUCTOR DUE TO CURRENTS FROM NEARBY EARTH ELECTRODES
    KRAKOWSKI, M
    [J]. PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1969, 116 (10): : 1701 - +
  • [24] Cable failure modes and effects risk analysis perspectives
    Nowlen, SP
    [J]. PROBABILISTIC SAFETY ASSESSMENT AND MANAGEMENT, VOL 1- 6, 2004, : 2481 - 2486
  • [25] DYNAMIC ANALYSIS OF MULTI-LOOP CABLE-STRING DOME DUE TO SUDDEN CABLE FAILURE
    Zhang C.
    Fu X.-D.
    Du X.-L.
    Yan X.-Y.
    Xu L.
    Jia H.-Y.
    [J]. Gongcheng Lixue/Engineering Mechanics, 2021, 38 (01): : 64 - 77
  • [26] Investigation of Noise Interference due to Connector Contact Failure in a Coaxial Cable
    Hayashi, Yu-ichi
    Mizuki, Takaaki
    Sone, Hideaki
    [J]. IEICE TRANSACTIONS ON ELECTRONICS, 2014, E97C (09): : 900 - 903
  • [27] Failure Prediction System of Water Treeing using 3D VLF Tandelta of MV Cable
    Lee, S. W.
    Heo, J. H.
    Park, H. G.
    Lee, E. C.
    Oh, C. S.
    Kim, S. W.
    Lim, J. S.
    [J]. 2017 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM), VOLS 1 & 2, 2017, : 291 - 294
  • [28] Risk-Controlled Application of Current MV Cable Feeders in the Future by Intelligent Continuous Diagnostics
    van der Wielen, Peter C. J. M.
    Steennis, E. Fred
    [J]. 2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [29] Phenylacetylglutamine as a risk factor and prognostic indicator of heart failure
    Zong, Xiao
    Fan, Qin
    Yang, Qian
    Pan, Roubai
    Zhuang, Lingfang
    Tao, Rong
    [J]. ESC HEART FAILURE, 2022, 9 (04): : 2645 - 2653
  • [30] Finite Element Analysis of Cable-Stayed Strands' Failure Due to Fire
    Ataei, Hossein
    Mamaghani, Mohammadhossein
    Aboutaha, Riyad S.
    [J]. FORENSIC ENGINEERING 2015: PERFORMANCE OF THE BUILT ENVIRONMENT, 2015, : 736 - 745