Accelerator based epithermal neutron source for clinical boron neutron capture therapy

被引:9
|
作者
Hu, Naonori [1 ,2 ]
Tanaka, Hiroki [2 ]
Akita, Kazuhiko [1 ]
Kakino, Ryo [1 ]
Aihara, Teruhito [1 ]
Nihei, Keiji [1 ]
Ono, Koji [1 ]
机构
[1] Osaka Med & Pharmaceut Univ, Kansai BNCT Med Ctr, Osaka, Japan
[2] Kyoto Univ, Inst Integrated Radiat & Nucl Sci, Kyoto, Japan
关键词
BNCT; Cyclotron; neutron detection; Monte Carlo simulation; commissioning; FACILITY;
D O I
10.3233/JNR-220037
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The world's first accelerator based epithermal neutron source for clinical boron neutron capture therapy (BNCT) was designed, developed, and commissioned between 2008 and 2010 by Sumitomo Heavy Industries in collaboration with Kyoto University at the Kyoto University Institute for Integrated Radiation and Nuclear Science. The accelerator system is cyclotron-based and accelerates a proton up to an energy of approximately 30 MeV. The proton strikes a beryllium target, which produces fast neutrons that traverse a beam shaping assembly composed of a combination of lead, iron, aluminum, and calcium fluoride to reduce the neutron energy down to the epithermal range (similar to 10 keV) suitable for BNCT. The system is designed to produce an epithermal neutron flux of up to 1.4 x 10(9) n . cm(-2) . s(-1) (exiting from the moderator of a 12 cm diameter collimator) with a proton current of 1 mA. In 2017, the same type of accelerator was installed at the Kansai BNCT Medical Center and in March 2020 the system received medical device approval in Japan (Sumitomo Heavy Industries, NeuCure (R) BNCT system). Soon after, BNCT for unresectable, locally advanced, and recurrent carcinoma of the head and neck region was approved by the Japanese government for reimbursement covered by the national health insurance system.
引用
收藏
页码:359 / 366
页数:8
相关论文
共 50 条
  • [31] Study of epithermal neutron columns for boron neutron capture therapy
    Oka, Y
    Akiyama, M
    An, S
    PROGRESS IN NUCLEAR ENERGY, 1998, 32 (1-2) : 61 - 70
  • [32] ACCELERATOR-BASED EPITHERMAL NEUTRON BEAM DESIGN FOR NEUTRON-CAPTURE THERAPY
    YANCH, JC
    ZHOU, XL
    SHEFER, RE
    KLINKOWSTEIN, RE
    MEDICAL PHYSICS, 1992, 19 (03) : 709 - 721
  • [33] Developments in accelerator based boron neutron capture therapy
    Green, S
    RADIATION PHYSICS AND CHEMISTRY, 1998, 51 (4-6): : 561 - 569
  • [34] CONCEPTUAL DESIGN OF AN RFQ ACCELERATOR-BASED NEUTRON SOURCE FOR BORON NEUTRON-CAPTURE THERAPY
    WANGLER, TP
    STOVALL, JE
    BHATIA, TS
    WANG, CK
    BLUE, TE
    GAHBAUER, RA
    PROCEEDINGS OF THE 1989 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: ACCELERATOR SCIENCE AND TECHNOLOGY, 1989, : 678 - 680
  • [35] Evaluation of moderator assemblies for use in an accelerator-based neutron source for boron neutron capture therapy
    Woollard, JE
    Blue, TE
    Gupta, N
    Gahbauer, RA
    NUCLEAR TECHNOLOGY, 1998, 123 (03) : 320 - 334
  • [36] Development and application of neutron field optimization parameters for an accelerator-based neutron source for boron neutron capture therapy
    Woollard, JE
    Blue, TE
    Gupta, N
    Gahbauer, RA
    NUCLEAR TECHNOLOGY, 1996, 115 (01) : 100 - 113
  • [37] Design of an accelerator-based neutron source for neutron capture therapy
    Terlizzi, R.
    Colonna, N.
    Colangelo, P.
    Maiorana, A.
    Marrone, S.
    Raino, A.
    Tagliente, G.
    Variale, V.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : S292 - S295
  • [38] Optimization of epithermal neutron field for cyclotron-based boron neutron capture therapy
    Yonai, S
    Aoki, T
    Nakamura, T
    Yashima, H
    Baba, M
    Yokohori, H
    Tahara, Y
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 299 - 303
  • [39] A PROTOTYPE EPITHERMAL NEUTRON BEAM FOR BORON NEUTRON-CAPTURE THERAPY
    NOONAN, DJ
    RUSSELL, JL
    BRUGGER, RM
    MEDICAL PHYSICS, 1986, 13 (02) : 211 - 216
  • [40] Microdosimetry of an accelerator based thermal neutron field for Boron Neutron Capture Therapy
    Selva, A.
    Bellan, L.
    Bianchi, A.
    Giustiniani, G.
    Colautti, P.
    Fagotti, E.
    Pisent, A.
    Conte, V.
    APPLIED RADIATION AND ISOTOPES, 2022, 182