Enhancing IgG purification from serum albumin containing feedstock with hydrophobic charge-induction chromatography

被引:47
|
作者
Tong, Hong-Fei [1 ]
Lin, Dong-Qiang [1 ]
Yuan, Xiao-Ming [1 ]
Yao, Shan-Jing [1 ]
机构
[1] Zhejiang Univ, Dept Chem & Biol Engn, State Key Lab Chem Engn, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金;
关键词
Hydrophobic charge-induction chromatography; Immunoglobulin G; Serum albumin; Purification; pH control; Salt addition; MIXED-MODE CHROMATOGRAPHY; PROTEIN ADSORPTION; ANTIBODY; LIGAND; ADSORBENTS; SEPARATION; CAPTURE; BINDING; PH;
D O I
10.1016/j.chroma.2012.04.073
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hydrophobic charge-induction chromatography (HCIC) with 4-mercaptoethyl-pyridine (MEP) as the ligand is a novel technology for antibody purification, however, the separation selectivity still needs to be improved for the applications, especially for the impurity of serum albumin. In this study, with bovine serum immunoglobulin G (IgG) as the model, the purification of IgG from the serum albumin containing feedstock was developed with the commercial HCIC resin MEP HyperCel, focusing on the optimization of operation pH and salt addition. The adsorption isotherms of IgG and bovine serum albumin (BSA) were investigated at different pHs, and the binding and elution behaviors of two proteins in the column were also studied at varying pHs. In addition, the protein-ligand interactions were investigated with some additives in the buffer. It was found that the conditions of pH 6 with 0.1 M NaCl or pH 8 could be used to effectively remove BSA from the MEP resin without the influence on IgG adsorption. Two modes with control of loading or washing buffer were tested to enhance the purification of IgG from BSA containing feedstock, and the purity of IgG was improved to about 95% compared with 62.9% for the control. The results demonstrated that the control of loading pH or the addition of NaCl in the buffer might be an effective method to improve the purification of antibody with the HCIC process. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:116 / 122
页数:7
相关论文
共 46 条
  • [11] Molecular mechanism of hydrophobic charge-induction chromatography: Interactions between the immobilized 4-mercaptoethyl-pyridine ligand and IgG
    Lin, Dong-Qiang
    Tong, Hong-Fei
    Wang, Hong-Yin
    Shao, Shuang
    Yao, Shan-Jing
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1260 : 143 - 153
  • [12] Experimental and in silico studies on three hydrophobic charge-induction adsorbents for porcine immunoglobulin purification
    Qilei Zhang
    Tiantian Zhuang
    Hongfei Tong
    Hongyin Wang
    Dongqiang Lin
    Shanjing Yao
    Chinese Journal of Chemical Engineering, 2016, 24 (01) : 151 - 157
  • [13] Experimental and in silico studies on three hydrophobic charge-induction adsorbents for porcine immunoglobulin purification
    Zhang, Qilei
    Zhuang, Tiantian
    Tong, Hongfei
    Wang, Hongyin
    Lin, Dongqiang
    Yao, Shanjing
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2016, 24 (01) : 151 - 157
  • [14] \Integration of Expanded Bed Adsorption and Hydrophobic Charge-Induction Chromatography for Monoclonal Antibody Separation
    Shi, Wei
    Gao, Dong
    Yao, Shan-Jing
    Lin, Dong-Qiang
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2017, 56 (03) : 765 - 773
  • [15] Preparation and evaluation of dextran-grafted agarose resin for hydrophobic charge-induction chromatography
    Liu, Tao
    Lin, Dong-Qiang
    Lu, Hui-Li
    Yao, Shan-Jing
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1369 : 116 - 124
  • [16] Antibody-Ligand Interactions for Hydrophobic Charge-Induction Chromatography: A Surface Plasmon Resonance Study
    Cheng, Fang
    Li, Ming-Yang
    Wang, Han-Qi
    Lin, Dong-Qiang
    Qu, Jing-Ping
    LANGMUIR, 2015, 31 (11) : 3422 - 3430
  • [17] Protein-Ligand interactions for hydrophobic charge-induction chromatography: A QCM-D study
    Ye, Jianlong
    Zhang, Yufeng
    Meng, Jianqiang
    APPLIED SURFACE SCIENCE, 2022, 572
  • [18] Penicillin acylase purification with the aid of hydrophobic charge induction chromatography
    Coulon, D
    Cabanne, C
    Fitton, V
    Noubhani, AM
    Saint-Christophe, E
    Santarelli, X
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 808 (01): : 111 - 115
  • [19] 5-Aminobenzimidazole as new hydrophobic charge-induction ligand for expanded bed adsorption of bovine IgG
    Shi, Wei
    Lin, Dong-Qiang
    Tong, Hong-Fei
    Yun, Jun-Xian
    Yao, Shan-Jing
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1425 : 97 - 105
  • [20] A novel polymer-grafted hydrophobic charge-induction chromatographic resin for enhancing protein adsorption capacity
    Liu, Tao
    Lin, Dong-Qiang
    Wu, Qi-Ci
    Zhang, Qi-Lei
    Wang, Cun-Xiang
    Yao, Shan-Jing
    CHEMICAL ENGINEERING JOURNAL, 2016, 304 : 251 - 258