The Domain Resonance Frequency Measurement of Inductively Coupled Resonant Sensors Using the Matrix Pencil Method

被引:0
|
作者
Sauer, Sebastian [1 ]
Fischer, Wolf-Joachim [2 ]
机构
[1] Tech Univ Dresden, Inst Semicond & Microsyst, D-01187 Dresden, Germany
[2] Fraunhofer IPMS, Wireless Microsyst, D-01109 Dresden, Germany
来源
关键词
PARAMETERS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Inductively coupled resonant (ICR) sensors can be used to determine environmental parameters. Hereby a measurand alters the sensor resonance frequency via an inductance, capacitance and/or resistance change. Due to their simple buildup these sensors are a promising approach for lowest cost, printed environmental parameter monitoring solutions. Commonly used are frequency domain techniques to determine sensor resonance frequencies, and time domain based signal analysis techniques, which evaluate the decaying sensor response, are only rarely employed. Within this work the Matrix Pencil Method is compared to several other time domain approaches. In numerical experiments carried out with a developed Matlab based test framework, a modified Matrix Pencil Method implementation did show a very good performance with regard to the relative frequency estimation error and algorithm robustness. The results were verified with applied laboratory measurements. When comparing the Matrix Pencil Method based wireless time domain resonance frequency measurement approach to wireless and wired frequency domain approaches, the differences of determined resonance frequencies of ICR sensor sample resonators are below 1%.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] A Resonance Frequency Tracker and Source Frequency Tuner for Inductively Coupled Wireless Power Transfer Systems
    Sis, Seyit Ahmet
    Bicakci, Sabri
    2016 46TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2016, : 751 - 754
  • [42] Monitoring microbial metabolites using an inductively coupled resonance circuit
    Daniil Karnaushenko
    Larysa Baraban
    Dan Ye
    Ilke Uguz
    Rafael G. Mendes
    Mark H. Rümmeli
    J. Arjan G. M. de Visser
    Oliver G. Schmidt
    Gianaurelio Cuniberti
    Denys Makarov
    Scientific Reports, 5
  • [43] Monitoring microbial metabolites using an inductively coupled resonance circuit
    Karnaushenko, Daniil
    Baraban, Larysa
    Ye, Dan
    Uguz, Ilke
    Mendes, Rafael G.
    Ruemmeli, Mark H.
    de Visser, J. Arjan G. M.
    Schmidt, Oliver G.
    Cuniberti, Gianaurelio
    Makarov, Denys
    SCIENTIFIC REPORTS, 2015, 5
  • [44] Optimization of Resonant Frequency Measurement Algorithm for Wireless Passive SAW Sensors
    Kalinin, V.
    Dixon, B.
    Beckley, J.
    2009 JOINT MEETING OF THE EUROPEAN FREQUENCY AND TIME FORUM AND THE IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, VOLS 1 AND 2, 2009, : 90 - 95
  • [45] On the Robust Measurement of Resonant Frequency and Quality Factor of Damped Resonating Sensors
    Niedermayer, A. O.
    Voglhuber-Brunnmaier, T.
    Sell, J.
    Jakoby, B.
    EUROSENSORS XXV, 2011, 25
  • [47] Impedance method for determining the mounted resonant frequency of piezoelectric sensors
    M. I. Subbotin
    Measurement Techniques, 1999, 42 : 801 - 802
  • [48] Development of inductively coupled wireless radio frequency coil for magnetic resonance scanners
    Sahara, Tomohiro
    Hashimoto, Shigehiro
    Tsutsui, Hiroshi
    Mochizuki, Shuichi
    Yamasaki, Kenichi
    Kondo, Hideo
    Yamada, Eiji
    Akazawa, Kenzo
    Okuyama, Kazuo
    Inoue, Yuichi
    2007 INAUGURAL IEEE INTERNATIONAL CONFERENCE ON DIGITAL ECOSYSTEMS AND TECHNOLOGIES, 2007, : 188 - +
  • [49] Pulsed dual-parameter measurement method for resonant sensors
    Dong, Yonggui
    Zhang, Qi
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2009, 49 (05): : 660 - 663
  • [50] Lower Bounds on the Frequency Estimation Error in Magnetically Coupled MEMS Resonant Sensors
    Paden, Brad E.
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2016, 10 (01) : 18 - 24