Novel membrane-tube type glaucoma shunt device for glaucoma surgery

被引:5
|
作者
Ahn, Byung Heon [1 ]
Hwang, Young Hoon [1 ]
Han, Jong Chul [2 ]
机构
[1] Konyang Univ, Dept Ophthalmol, Kims Eye Hosp, Myung Gok Eye Res Inst, 156 Youngdeungpo Dong 4ga, Seoul 150034, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Ophthalmol, Seoul, South Korea
来源
关键词
glaucoma; glaucoma drainage device; intraocular pressure; surgery; trabeculectomy; FOLLOW-UP; TRABECULECTOMY; MODULATION; IMPLANT;
D O I
10.1111/ceo.12772
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The background of this study is to introduce the surgical technique and outcomes of a novel membrane-tube (MT) type glaucoma shunt device (MicroMT), which was developed to achieve safer and more predictable intraocular pressure (IOP) control compared with conventional trabeculectomy. Design: This is a retrospective, non-comparative, interventional case series study. Participants: The MicroMT was implanted in 43 glaucomatous eyes with insufficient IOP control despite medical treatment. Methods: The MicroMT consists of an expanded polytetrafluoroethylene membrane and a silicone tube with an intraluminal stent, which allows aqueous drainage from the anterior chamber to the lamellar scleral flap. The intraluminal stent prevents excessive aqueous drainage and allows additional IOP reduction through retraction or removal of the stent. Main Outcome Measures: The main outcome measures of this study are IOP changes and complications. Results: The mean (SD) IOP decreased from a preoperative value of 22.5 (6.9) mmHg to 11.1 (3.6) mmHg 3 years after the operation (50.7% reduction from baseline; P<0.01). Intraluminal stent removal 4 weeks after the operation induced an additional 40.2% IOP reduction (P<0.01). When success was defined as an IOP between 6 and 21 mmHg, and an IOP reduction of >= 20% from baseline, the success rate was 89.5% at 3 years after the operation. No postoperative ocular hypotony (IOP <6 mmHg) or tube-related complications occurred. Conclusions: MicroMT implantation is a novel therapy that may reduce IOP safely and effectively, with no apparent risk of postoperative ocular hypotony. Glaucoma surgery using this device may be a good alternative to conventional glaucoma surgery.
引用
收藏
页码:776 / 782
页数:7
相关论文
共 50 条
  • [31] Need for Additional Glaucoma Surgery and Complications Following Glaucoma Drainage Device Surgery
    Kung, Felix F.
    Knier, Catherine G.
    Garmany, Armin
    Mejia, Camilo A.
    Sargent, Jason M.
    Dogahe, Sepideh Jamali
    Sabbagh, Nouran
    Hodge, David O.
    Khanna, Cheryl L.
    JOURNAL OF GLAUCOMA, 2021, 30 (06) : 508 - 514
  • [32] Tube-shunt surgery versus neodymium:YAG cyclophotocoagulation in the management of neovascular glaucoma
    Eid, TE
    Katz, LJ
    Spaeth, GL
    Augsburger, JJ
    OPHTHALMOLOGY, 1997, 104 (10) : 1692 - 1700
  • [33] Effect of Early Aqueous Suppression After Valved Tube Shunt Surgery for Uveitic Glaucoma
    Tang, Minjia
    Gill, Nathan P.
    Tanna, Angelo P.
    OPHTHALMOLOGY GLAUCOMA, 2024, 7 (01): : 37 - 46
  • [34] CLINICAL-RESULTS OF GLAUCOMA SURGERY USING THE WHITE GLAUCOMA PUMP SHUNT
    WHITE, TC
    ANNALS OF OPHTHALMOLOGY, 1992, 24 (10): : 365 - 373
  • [35] Results of Trabectome Surgery Following Failed Glaucoma Tube Shunt Implantation Cohort Study
    Mosaed, Sameh
    Chak, Garrick
    Haider, Asghar
    Lin, Ken Y.
    Minckler, Don S.
    MEDICINE, 2015, 94 (30)
  • [36] Optonol ExPRESS™ miniature tube shunt in advanced glaucoma
    Wamsley, S
    Moster, MR
    Rai, S
    Alvim, H
    Fontanarosa, J
    Steinmann, C
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U376 - U376
  • [37] Technique of Combined Glaucoma Tube Shunt and Keratoprosthesis Implantation
    Law, Simon K.
    Huang, Jennifer S.
    Nassiri, Nariman
    Moghimi, Sasan
    Nilforushan, Naveed
    Parham, Azarbod
    Moossai, Jonathan
    Kim, Michelle
    Caprioli, Joseph
    Aldave, Anthony J.
    JOURNAL OF GLAUCOMA, 2014, 23 (08) : 501 - 507
  • [38] Surgical outcome of tube shunt implantation for pediatric glaucoma
    Zhang, Xinyu
    Yang, Alina
    Liu, Ji
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [39] Filtration/Tube surgery in exfoliation glaucoma
    Gottfredsdottir, M. S.
    ACTA OPHTHALMOLOGICA, 2010, 88 : 8 - 8
  • [40] Outcomes of combined glaucoma tube shunt and fluocinolone acetonide implant placement in uveitic patients compared to outcomes in uveitic and open angle glaucoma patients with glaucoma tube shunt placement alone
    Moore, Daniel
    Asrani, Sanjay
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)