The learning curve associated with robotic-arm assisted unicompartmental knee arthroplasty A PROSPECTIVE COHORT STUDY

被引:99
|
作者
Kayani, B. [1 ,2 ]
Konan, S. [1 ,2 ]
Pietrzak, J. R. T. [1 ,2 ]
Huq, S. S. [1 ,2 ,3 ]
Tahmassebi, J. [1 ,2 ,3 ]
Haddad, F. S. [1 ,2 ,4 ,5 ]
机构
[1] Princess Grace Hosp, London, England
[2] Univ Coll Hosp, London, England
[3] Univ Coll Hosp, Dept Trauma & Orthopaed, London, England
[4] Univ Coll London Hosp, Orthopaed Surg, Princess Grace Hosp, London, England
[5] UCLH, NIHR Biomed Res Ctr, London, England
来源
BONE & JOINT JOURNAL | 2018年 / 100B卷 / 08期
关键词
REPLACEMENT;
D O I
10.1302/0301-620X.100B8.BJJ-2018-0040.R1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims The primary aim of this study was to determine the surgical team's learning curve for introducing robotic-arm assisted unicompartmental knee arthroplasty (UKA) into routine surgical practice. The secondary objective was to compare accuracy of implant positioning in conventional jig-based UKA versus robotic-arm assisted UKA. Patients and Methods This prospective single-surgeon cohort study included 60 consecutive conventional jig-based UKAs compared with 60 consecutive robotic-arm assisted UKAs for medial compartment knee osteoarthritis. Patients undergoing conventional UKA and robotic-arm assisted UKA were well-matched for baseline characteristics including a mean age of 65.5 years (SD 6.8) vs 64.1 years (SD 8.7), (p = 0.31); a mean body mass index of 27.2 kg.m(2) (SD 2.7) vs 28.1 kg.m(2) (SD 4.5), (p = 0.25); and gender (27 males: 33 females vs 26 males: 34 females, p = 0.85). Surrogate measures of the learning curve were prospectively collected. These included operative times, the Spielberger State-Trait Anxiety Inventory (STAI) questionnaire to assess preoperative stress levels amongst the surgical team, accuracy of implant positioning, limb alignment, and postoperative complications. Results Robotic-arm assisted UKA was associated with a learning curve of six cases for operating time (p < 0.001) and surgical team confidence levels (p < 0.001). Cumulative robotic experience did not affect accuracy of implant positioning (p = 0.52), posterior condylar offset ratio (p = 0.71), posterior tibial slope (p = 0.68), native joint line preservation (p = 0.55), and postoperative limb alignment (p = 0.65). Robotic-arm assisted UKA improved accuracy of femoral (p < 0.001) and tibial (p < 0.001) implant positioning with no additional risk of postoperative complications compared to conventional jig-based UKA. Conclusion Robotic-arm assisted UKA was associated with a learning curve of six cases for operating time and surgical team confidence levels but no learning curve for accuracy of implant positioning.
引用
收藏
页码:1033 / 1042
页数:10
相关论文
共 50 条
  • [41] Robotic-assisted unicompartmental knee arthroplasty: a review
    Pei Liu
    Fei-fan Lu
    Guo-jie Liu
    Xiao-hong Mu
    Yong-qiang Sun
    Qi-dong Zhang
    Wei-guo Wang
    Wan-shou Guo
    Arthroplasty, 3
  • [42] Robotic-assisted unicompartmental knee arthroplasty: a review
    Liu, Pei
    Lu, Fei-fan
    Liu, Guo-jie
    Mu, Xiao-hong
    Sun, Yong-qiang
    Zhang, Qi-dong
    Wang, Wei-guo
    Guo, Wan-shou
    ARTHROPLASTY, 2021, 3 (01)
  • [43] ROBOTIC-ARM ASSISTED TOTAL KNEE SURGERY: AN ECONOMIC ANALYSIS
    Pierce, J.
    Needham, K. A.
    Adams, C.
    Coppolecchia, A.
    Lavernia, C.
    VALUE IN HEALTH, 2020, 23 : S386 - S386
  • [44] Accuracy in the Execution of Pre-operative Plan for Limb Alignment and Implant Positioning in Robotic-arm Assisted Total Knee Arthroplasty and Manual Total Knee Arthroplasty: A Prospective Observational Study
    Thilak, Jai
    Babu, Balu C.
    Thadi, Mohan
    Mohan, Vipin
    Kumar, T. Arun
    Mane, Prajwal P.
    Ravindran, Greeshma C.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2021, 55 (04) : 953 - 960
  • [45] Accuracy in the Execution of Pre-operative Plan for Limb Alignment and Implant Positioning in Robotic-arm Assisted Total Knee Arthroplasty and Manual Total Knee Arthroplasty: A Prospective Observational Study
    Jai Thilak
    Balu C. Babu
    Mohan Thadi
    Vipin Mohan
    T. Arun Kumar
    Prajwal P. Mane
    Greeshma C. Ravindran
    Indian Journal of Orthopaedics, 2021, 55 : 953 - 960
  • [46] The Learning Curve of Reaching the Planned Limb Alignment in Robotic-Arm-Assisted Total Knee Arthroplasty
    Pannu, Tejbir S.
    Villa, Jesus M.
    Schultz, Isaac
    Barsoum, Wael K.
    Higuera, Carlos A.
    Patel, Preetesh D.
    JOURNAL OF KNEE SURGERY, 2023, 36 (06) : 682 - 688
  • [47] Midterm Survivorship and Patient Satisfaction of Robotic-Arm-Assisted Medial Unicompartmental Knee Arthroplasty: A Multicenter Study
    Kleeblad, Laura J.
    Borus, Todd A.
    Coon, Thomas M.
    Dounchis, Jon
    Nguyen, Joseph T.
    Pearle, Andrew D.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (06): : 1719 - 1726
  • [48] MAKO Robotic-Arm Assisted Total Knee Arthroplasty: Surgical Technique From the Office to the Operating Room
    Yohe, Nicholas
    Chen, Zhongming
    Mont, Michael A.
    Sultan, Assem A.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2021, 39
  • [49] ROBOTIC-ARM-ASSISTED LATERAL UNICOMPARTMENTAL KNEE ARTHROPLASTY WITH A FIXED-BEARING IMPLANT
    Premkumar, Ajay
    Bayoumi, Tarik
    Pearle, Andrew D.
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2023, 13 (02):
  • [50] Early outcomes after robotic arm-assisted bi-unicompartmental knee arthroplasty compared with total knee arthroplasty: a prospective, randomized controlled trial
    Blyth, M. J. G.
    Banger, M. S.
    Doonan, J.
    Jones, B. G.
    MacLean, A. D.
    Rowe, P. J.
    BONE & JOINT JOURNAL, 2021, 103B (10): : 1561 - 1570