The learning curve associated with robotic-arm assisted unicompartmental knee arthroplasty A PROSPECTIVE COHORT STUDY

被引:99
|
作者
Kayani, B. [1 ,2 ]
Konan, S. [1 ,2 ]
Pietrzak, J. R. T. [1 ,2 ]
Huq, S. S. [1 ,2 ,3 ]
Tahmassebi, J. [1 ,2 ,3 ]
Haddad, F. S. [1 ,2 ,4 ,5 ]
机构
[1] Princess Grace Hosp, London, England
[2] Univ Coll Hosp, London, England
[3] Univ Coll Hosp, Dept Trauma & Orthopaed, London, England
[4] Univ Coll London Hosp, Orthopaed Surg, Princess Grace Hosp, London, England
[5] UCLH, NIHR Biomed Res Ctr, London, England
来源
BONE & JOINT JOURNAL | 2018年 / 100B卷 / 08期
关键词
REPLACEMENT;
D O I
10.1302/0301-620X.100B8.BJJ-2018-0040.R1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims The primary aim of this study was to determine the surgical team's learning curve for introducing robotic-arm assisted unicompartmental knee arthroplasty (UKA) into routine surgical practice. The secondary objective was to compare accuracy of implant positioning in conventional jig-based UKA versus robotic-arm assisted UKA. Patients and Methods This prospective single-surgeon cohort study included 60 consecutive conventional jig-based UKAs compared with 60 consecutive robotic-arm assisted UKAs for medial compartment knee osteoarthritis. Patients undergoing conventional UKA and robotic-arm assisted UKA were well-matched for baseline characteristics including a mean age of 65.5 years (SD 6.8) vs 64.1 years (SD 8.7), (p = 0.31); a mean body mass index of 27.2 kg.m(2) (SD 2.7) vs 28.1 kg.m(2) (SD 4.5), (p = 0.25); and gender (27 males: 33 females vs 26 males: 34 females, p = 0.85). Surrogate measures of the learning curve were prospectively collected. These included operative times, the Spielberger State-Trait Anxiety Inventory (STAI) questionnaire to assess preoperative stress levels amongst the surgical team, accuracy of implant positioning, limb alignment, and postoperative complications. Results Robotic-arm assisted UKA was associated with a learning curve of six cases for operating time (p < 0.001) and surgical team confidence levels (p < 0.001). Cumulative robotic experience did not affect accuracy of implant positioning (p = 0.52), posterior condylar offset ratio (p = 0.71), posterior tibial slope (p = 0.68), native joint line preservation (p = 0.55), and postoperative limb alignment (p = 0.65). Robotic-arm assisted UKA improved accuracy of femoral (p < 0.001) and tibial (p < 0.001) implant positioning with no additional risk of postoperative complications compared to conventional jig-based UKA. Conclusion Robotic-arm assisted UKA was associated with a learning curve of six cases for operating time and surgical team confidence levels but no learning curve for accuracy of implant positioning.
引用
收藏
页码:1033 / 1042
页数:10
相关论文
共 50 条
  • [1] Robotic-arm assisted unicompartmental knee arthroplasty system has a learning curve of 11 cases and increased operating time
    Tay, Mei Lin
    Carter, Matthew
    Bolam, Scott M.
    Zeng, Nina
    Young, Simon W.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2023, 31 (03) : 793 - 802
  • [2] Robotic-arm assisted unicompartmental knee arthroplasty system has a learning curve of 11 cases and increased operating time
    Mei Lin Tay
    Matthew Carter
    Scott M. Bolam
    Nina Zeng
    Simon W. Young
    Knee Surgery, Sports Traumatology, Arthroscopy, 2023, 31 : 793 - 802
  • [3] Robotic-arm assisted lateral unicompartmental knee arthroplasty: 5-Year outcomes & survivorship
    Gaudiani, Michael A.
    Samuel, Linsen T.
    Diana, John N.
    DeBattista, Jennifer L.
    Coon, Thomas M.
    Moore, Ryan E.
    Kamath, Atul F.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2023, 31 (01)
  • [4] Robotic-arm assisted medial unicondylar knee arthroplasty versus jig-based unicompartmental knee arthroplasty with navigation control: study protocol for a prospective randomised controlled trial
    Kayani, Babar
    Konan, Sujith
    Tahmassebi, Jenni
    Ayuob, Atif
    Moriarty, Peter D.
    Haddad, Fares S.
    TRIALS, 2020, 21 (01)
  • [5] Robotic-arm assisted medial unicondylar knee arthroplasty versus jig-based unicompartmental knee arthroplasty with navigation control: study protocol for a prospective randomised controlled trial
    Babar Kayani
    Sujith Konan
    Jenni Tahmassebi
    Atif Ayuob
    Peter D. Moriarty
    Fares S. Haddad
    Trials, 21
  • [6] Safety and Effectiveness of Robotic-Arm Assisted Total Knee Arthroplasty
    Yuan, Mingcheng
    Ling, Tingxian
    Su, Qiang
    Wan, Xufeng
    Lai, Yahao
    Zhou, Zongke
    ORTHOPAEDIC SURGERY, 2024, 16 (04) : 882 - 893
  • [7] Introduction of ROSA robotic-arm system for total knee arthroplasty is associated with a minimal learning curve for operative time
    Bolam, Scott M.
    Tay, Mei Lin
    Zaidi, Faseeh
    Sidaginamale, Raghavendra P.
    Hanlon, Michael
    Munro, Jacob T.
    Monk, A. Paul
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2022, 9 (01)
  • [8] Introduction of ROSA robotic-arm system for total knee arthroplasty is associated with a minimal learning curve for operative time
    Scott M. Bolam
    Mei Lin Tay
    Faseeh Zaidi
    Raghavendra P. Sidaginamale
    Michael Hanlon
    Jacob T. Munro
    A. Paul Monk
    Journal of Experimental Orthopaedics, 9
  • [9] Mako™ Robotic-Arm Assisted Medial Unicompartmental Knee Arthroplasty: Surgical Technique from the Office to the Operating Room
    Buechel, Frederick F., Jr.
    Angerett, Nathan R.
    Chen, Zhongming
    Vakharia, Rushabh M.
    Marchand, Robert C.
    Mont, Michael A.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2023, 42
  • [10] Arthroscopic Robotic Arm-assisted Unicompartmental Knee Arthroplasty
    O'Loughlin, Padhraig F.
    Pearle, Andrew D.
    Fyhrie, David P.
    Long, Fanxin
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2009, 17 (04) : 266 - 267