Analysis and Design of a Microwave Coplanar Sensor for Non-Invasive Blood Glucose Measurements

被引:35
|
作者
Cebedio, Maria Celeste [1 ]
Rabioglio, Lucas Andres [1 ]
Gelosi, Ivan Exequiel [1 ]
Ribas, Ramiro Avalos [1 ]
Uriz, Alejandro Jose [1 ]
Moreira, Jorge Castineira [1 ]
机构
[1] Natl Univ Mar Del Plata, Sch Engn, CONICET, ICYTE UNMdP, RA-7600 Mar Del Plata, Argentina
关键词
Blood; Glucose; Sensors; Resonant frequency; Frequency measurement; Microwave measurement; Microwave theory and techniques; Glucometers; non-invasive sensors; microwave resonators; blood glucose; RESONATOR; SKIN;
D O I
10.1109/JSEN.2020.2993182
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper a design for a microwave sensor for the non-invasive measurement of blood glucose concentrations is proposed. The sensor is intended for usage as part of a non-invasive glucose-quantifying device. With this aim, three different microwave resonator structures are analyzed as possible candidates, and strengths and weaknesses are highlighted in each case. The chosen resonator is an open structure in which a finger of the patient is placed, fulfilling the role of a sample to be characterized by the sensor. The shape and size of the finger thus condition those of the resonator. Variations in the concentration of blood glucose modify the dielectric properties of the tissue, which is part of the microwave resonator-finger system, and as such, the changes translate to the resonance frequency of the whole structure. Among the three studied topologies, it was found that a single resonator designed using a coplanar structure with a ground plane showed the best trade-off in frequency sensitivity, stability and repeatability of the measurements. A notable correlation, between the resonance frequency of the proposed sensor and the blood glucose levels measured with a traditional glucometer, was found. This highlights a potential interchangeability of both glucose measurement methods.
引用
收藏
页码:10572 / 10581
页数:10
相关论文
共 50 条
  • [21] Microwave Non-Invasive Blood Glucose Detection Based on Debye Model
    Hu Min
    Xiao Xia
    Song Hang
    Liu Yu
    LASER & OPTOELECTRONICS PROGRESS, 2020, 57 (23)
  • [22] A Novel Miniature Spiral Sensor for Non-invasive Blood Glucose Monitoring
    Shao, Jinjin
    Yang, Fan
    Xia, Fen
    Zhang, Qingfeng
    Chen, Yifan
    2016 10TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2016,
  • [23] Development of a novel non-invasive sensor for the determination of the blood glucose concentration
    Böckle, S
    Rovati, L
    Ansari, RR
    HYBRID AND NOVEL IMAGING AND NEW OPTICAL INSTRUMENTATION FOR BIOMEDICAL APPLICATIONS, 2001, 4434 : 260 - 262
  • [24] Non-Invasive Assessment of Blood Glucose Changes with Near Infrared Sensor
    Mamilov, Serhii
    Velyhotskyi, Dmytro
    Yesman, Serhii
    Mysiura, Anatolii
    Bekh, Ihor
    Gisbrecht, Alexander
    2020 IEEE 40TH INTERNATIONAL CONFERENCE ON ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2020, : 536 - 540
  • [25] Investigation of the specificity of Raman spectroscopy in non-invasive blood glucose measurements
    Dingari, Narahara Chari
    Barman, Ishan
    Singh, Gajendra P.
    Kang, Jeon Woong
    Dasari, Ramachandra R.
    Feld, Michael S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (09) : 2871 - 2880
  • [26] Development of a non-invasive blood glucose monitor based on impedance measurements
    Malinin, Len
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2012, 8 (01) : 60 - 81
  • [27] Evaluation of a global modeling approach for non-invasive blood glucose measurements
    Monfre, SL
    Ruchti, TL
    Blank, TB
    Lorenz, AD
    DIABETOLOGIA, 2001, 44 : A45 - A45
  • [28] Investigation of the specificity of Raman spectroscopy in non-invasive blood glucose measurements
    Narahara Chari Dingari
    Ishan Barman
    Gajendra P. Singh
    Jeon Woong Kang
    Ramachandra R. Dasari
    Michael S. Feld
    Analytical and Bioanalytical Chemistry, 2011, 400 : 2871 - 2880
  • [29] Design of Microstrip Sensor for Non invasive Blood Glucose Monitoring
    Satish
    Sen, Kushal
    Anand, Sneh
    2017 INTERNATIONAL CONFERENCE ON EMERGING TRENDS & INNOVATION IN ICT (ICEI), 2017, : 5 - 8
  • [30] Non-invasive Estimation of Blood Glucose
    Sidley, Matthew
    Venkataraman, Jayanti
    2013 IEEE APPLIED ELECTROMAGNETICS CONFERENCE (AEMC), 2013,