Measuring intra-abdominal pressure outside the ICU: Validation of a simple bedside method

被引:0
|
作者
Cheatham, Michael L. [1 ]
Fowler, Jessica [2 ]
机构
[1] Orlando Reg Med Ctr Inc, Dept Surg Educ, Orlando, FL 32806 USA
[2] Florida State Univ, Coll Med, Tallahassee, FL 32306 USA
关键词
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Intra-abdominal pressure measurement is essential to the diagnosis of patients with intra-abdominal hypertension or abdominal compartment syndrome. The most common method for measuring intra-abdominal pressure (IAP) is the intravesicular or "bladder" technique, which requires electronic monitoring technology not available on the typical surgical ward. Herein we describe and validate a simple, rapid screening method for bedside IAP measurement using the patient's indwelling urinary catheter and a readily available intravenous tubing extension. Validation of this technique across the clinically important IAP diagnostic spectrum demonstrated acceptable bias (1.6 mm Hg; 95%, confidence interval 1.4-1.8) with limits of agreement of 0.36 to 2.8. This demonstrates good agreement between the two IAP methods and validates the bedside technique as a simple, cost-effective, and reproducible method for screening IAP measurements outside of the critical care setting.
引用
下载
收藏
页码:806 / 808
页数:3
相关论文
共 50 条
  • [41] Abdominal Wall Movements Predict Intra-Abdominal Pressure Changes in Rats: A Novel Non-Invasive Intra-Abdominal Pressure Detection Method
    Vincent, Deirdre
    Mietzsch, Stefan
    Braun, Wolfgang
    Trochimiuk, Magdalena
    Reinshagen, Konrad
    Boettcher, Michael
    Lugli, Licia
    CHILDREN-BASEL, 2023, 10 (08):
  • [42] 116 Measuring of Intra-Abdominal Pressure in Critically Ill Children by Nurses
    M M Van De Polder
    S Plug
    C Buth
    N Van Beelen
    R J Houmes
    E Ista
    Pediatric Research, 2010, 68 (Suppl 1) : 61 - 62
  • [43] Relationship between intracranial (ICP) and intra-abdominal pressure (IAP) in ICU patients
    Deeren, D
    Daelemans, R
    Lins, R
    Malbrain, ML
    Leijs, J
    Vandenbrande, E
    CRITICAL CARE MEDICINE, 2003, 31 (12) : A89 - A89
  • [44] Validation of transurethral intra-abdominal pressure measurement in acute heart failure
    Zymlinski, Robert
    Biegus, Jan
    Sokolski, Mateusz
    Jankowska, Ewa A.
    Banasiak, Waldemar
    Ponikowski, Piotr
    POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ, 2018, 128 (06): : 403 - 405
  • [45] INTERIM RESULTS ON THE VALIDATION OF A NOVEL METHOD FOR MEASURING GASTRIC RESIDUAL VOLUME AND INTRA-ABDOMINAL PRESSURE IN MECHANICALLY VENTILATED CRITICALLY ILL PATIENTS
    Malbrain, M.
    Palmers, P. -J.
    Tepaske, R.
    Valtysson, J.
    Van Ingelgem, A.
    Van Regenmortel, N.
    De laet, I.
    Schoonheydt, K.
    Dits, H.
    INTENSIVE CARE MEDICINE, 2010, 36 : S372 - S372
  • [46] A novel technique of intra-abdominal pressure measurement:validation of two prototypes
    MLNG Malbrain
    M Léonard
    D Delmarcelle
    Critical Care, 6 (Suppl 1):
  • [47] Evaluation of the Spiegelberg method and the bladder method with different intravesical volumes for measurement of intra-abdominal pressure in a porcine model of intra-abdominal hypertension
    J Wauters
    P Claus
    N Brosens
    M Malbrain
    A Wilmer
    Critical Care, 10 (Suppl 1):
  • [48] Integration of inspiratory and expiratory intra-abdominal pressure: a novel concept looking at mean intra-abdominal pressure
    Ahmadi-Noorbakhsh, Siavash
    Malbrain, Manu L. N. G.
    ANNALS OF INTENSIVE CARE, 2012, 2
  • [49] Integration of inspiratory and expiratory intra-abdominal pressure: a novel concept looking at mean intra-abdominal pressure
    Siavash Ahmadi-Noorbakhsh
    Manu LNG Malbrain
    Annals of Intensive Care, 2
  • [50] INTRAPERITONEAL PRESSURE AND INTRA-ABDOMINAL PRESSURE: ARE THEY THE SAME?
    Al-Hwiesh, Abdullah
    Al-Mueilo, Sameer
    Saeed, Ibrahiem
    Al-Muhanna, Fahd A.
    PERITONEAL DIALYSIS INTERNATIONAL, 2011, 31 (03): : 315 - 319