Measuring intra-abdominal pressure outside the ICU: Validation of a simple bedside method

被引:0
|
作者
Cheatham, Michael L. [1 ]
Fowler, Jessica [2 ]
机构
[1] Orlando Reg Med Ctr Inc, Dept Surg Educ, Orlando, FL 32806 USA
[2] Florida State Univ, Coll Med, Tallahassee, FL 32306 USA
关键词
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Intra-abdominal pressure measurement is essential to the diagnosis of patients with intra-abdominal hypertension or abdominal compartment syndrome. The most common method for measuring intra-abdominal pressure (IAP) is the intravesicular or "bladder" technique, which requires electronic monitoring technology not available on the typical surgical ward. Herein we describe and validate a simple, rapid screening method for bedside IAP measurement using the patient's indwelling urinary catheter and a readily available intravenous tubing extension. Validation of this technique across the clinically important IAP diagnostic spectrum demonstrated acceptable bias (1.6 mm Hg; 95%, confidence interval 1.4-1.8) with limits of agreement of 0.36 to 2.8. This demonstrates good agreement between the two IAP methods and validates the bedside technique as a simple, cost-effective, and reproducible method for screening IAP measurements outside of the critical care setting.
引用
下载
收藏
页码:806 / 808
页数:3
相关论文
共 50 条
  • [1] Intra-abdominal pressure measurement: validation of intragastric pressure as a measure of intra-abdominal pressure
    Turnbull, D.
    Webber, S.
    Hamnegard, C. H.
    Mills, G. H.
    BRITISH JOURNAL OF ANAESTHESIA, 2007, 98 (05) : 628 - 634
  • [2] In Search of a Simple and Reliable Method of Measuring Intra-abdominal Pressure in Peritoneal Dialysis Patients
    Thangarasa, Tharshika
    Foisy, Dana
    Leidecker, Julie
    Corsi, Daniel J.
    Meggison, Hilary
    Blew, Brian
    Warren, Jeffery
    Zimmerman, Deborah
    CANADIAN JOURNAL OF KIDNEY HEALTH AND DISEASE, 2019, 6
  • [3] Preliminary results on the validation of a novel method for measuring intra-abdominal pressure and gastric residual volume
    M Malbrain
    R Tepaske
    J Valtysson
    P Palmers
    A Van Ingelgem
    N Van Regenmortel
    I De laet
    K Schoonheydt
    H Dits
    Critical Care, 14 (Suppl 1):
  • [4] INTRA-ABDOMINAL HYPERTENSION-DOES IT EXIST OUTSIDE ICU?
    Waldron, Ruth
    Ryan, Louise
    Sugrue, Michael
    Kristofferson, Lee
    ACTA CLINICA BELGICA, 2009, 64 (03): : 276 - 276
  • [5] Capacitive Sensor for Measuring of Intra-Abdominal Pressure
    Jurcisin, Michal
    Slosarcik, Stanislav
    Gmiterko, Alexander
    Cabuk, Pavol
    2011 34TH INTERNATIONAL SPRING SEMINAR ON ELECTRONICS TECHNOLOGY (ISSE 2011) - NEW TRENDS IN MICRO/NANOTECHNOLOGY, 2011, : 583 - 586
  • [6] Intra-Abdominal Pressure: Why Are You Not Measuring It?
    Cheatham, Michael L.
    CRITICAL CARE MEDICINE, 2014, 42 (02) : 467 - 469
  • [7] Validation of a novel method for measuring intra-abdominal pressure and gastric residual volume in critically ill patients
    Van Stappen, Johan
    Pigozzi, Chiara
    Tepaske, Robert
    Van Regenmortel, Niels
    De laet, Inneke
    Schoonheydt, Karen
    Dits, Hilde
    Severgnini, Paolo
    Roberts, Derek J.
    Malbrain, Manu Lng
    ANAESTHESIOLOGY INTENSIVE THERAPY, 2014, 46 (04) : 245 - 254
  • [8] A SIMPLE TECHNIQUE TO DETERMINE INTRA-ABDOMINAL PRESSURE
    COAD, NR
    HUTCHINSON, A
    CRITICAL CARE MEDICINE, 1989, 17 (12) : 1364 - 1365
  • [9] Predictive ability of intra-abdominal pressure for ICU mortality
    Kompoti, Maria
    Michalia, Martha
    Clouva-Molyvdas, Phyllis-Maria
    INTENSIVE CARE MEDICINE, 2009, 35 (09) : 1650 - 1650
  • [10] Predictive ability of intra-abdominal pressure for ICU mortality
    Maria Kompoti
    Martha Michalia
    Phyllis-Maria Clouva-Molyvdas
    Intensive Care Medicine, 2009, 35 : 1650 - 1650