A light intensity measurement system for the analytical ultracentrifuge

被引:6
|
作者
Laue, Thomas M. [1 ]
Austin, Joseph B. [1 ]
Rau, David A. [1 ]
机构
[1] Univ New Hampshire, Ctr Adv Mol Interact Sci, Rudman Hall-379, Durham, NH 03824 USA
来源
关键词
absorbance detector; analytical ultracentrifugation; detector systems; fluorescence detector; instrumentation software;
D O I
10.1007/2882_001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Light intensity measurements are required by absorbance, fluorescence, turbidity and low-angle light scattering detectors in order to determine the concentration distributions encountered in analytical ultracentrifugation. By using four fast analog-to-digital converters operating in parallel, a data acquisition system has been developed for the analytical ultracentrifuge that can acquire light intensity readings from three detectors (e.g. photomultipliers, avalanche photodiodes, etc.) simultaneously. For each detector, up to forty thousand intensity readings are acquired during each rotor revolution, for up to ten revolutions. Software synchronizes data acquisition with the spinning rotor. The use of continuous light sources allows simultaneous acquisition of dozens of intensity readings from all of the samples. Data acquisition is fast, allowing rapid radial scanning of samples. This data acquisition scheme is used in the Aviv Biomedical AU-FDS fluorescence detection retrofit system for the Beckman XLI analytical ultracentrifuge. It also will be used for the updated XLI absorbance system, as well as the next generation of analytical ultracentrifuge.
引用
收藏
页码:1 / +
页数:2
相关论文
共 50 条
  • [41] Measuring compressibility in the optima AUC™ analytical ultracentrifuge
    Marielle Stoutjesdyk
    Emre Brookes
    Amy Henrickson
    Borries Demeler
    European Biophysics Journal, 2020, 49 : 711 - 718
  • [42] VISUALIZATION OF REVERSIBLE MACROMOLECULAR REACTIONS IN AN ANALYTICAL ULTRACENTRIFUGE
    CHERNYAK, VY
    KOGANYASNY, VV
    EUROPEAN JOURNAL OF BIOCHEMISTRY, 1988, 178 (02): : 465 - 469
  • [43] System for Low Intensity Fluorescence Light Measurement based on Silicon Photomultiplier.
    Mik, Lukasz
    Stepien, Jacek
    Jastrzab, Marcin
    Kucewicz, Wojciech
    Sapor, Maria
    INTERNATIONAL CONFERENCE ON SIGNALS AND ELECTRONIC SYSTEMS (ICSES '10): CONFERENCE PROCEEDINGS, 2010, : 383 - 386
  • [44] DOUBLE BEAM SCANNING SPECTOPHOTOMETER FOR ANALYTICAL ULTRACENTRIFUGE
    NEIMARK, J
    POUYET, J
    REVUE DE PHYSIQUE APPLIQUEE, 1970, 5 (06): : 877 - &
  • [45] PRECONSTRUCTION OF DENSITY GRADIENTS IN CELLS OF ANALYTICAL ULTRACENTRIFUGE
    MORROD, RS
    SPRAGG, SP
    ANALYTICAL BIOCHEMISTRY, 1974, 62 (02) : 604 - 608
  • [46] Reincarnation of the Analytical Ultracentrifuge: Emerging Opportunities for Nanomedicine
    Valderrama, Olenka Jibaja
    Nischang, Ivo
    ANALYTICAL CHEMISTRY, 2021, 93 (48) : 15805 - 15815
  • [47] DYNAMIC ERRORS OF PHOTOELECTRICAL SCANNER OF AN ANALYTICAL ULTRACENTRIFUGE
    LOTTS, YA
    MARGOLIN, AK
    SAMBURSKII, AI
    VYSOKOMOLEKULYARNYE SOEDINENIYA SERIYA A, 1975, 17 (05): : 1181 - 1186
  • [48] 2 EXPERIMENTS IN ONE RUN WITH THE ANALYTICAL ULTRACENTRIFUGE
    BON, WF
    RECUEIL DES TRAVAUX CHIMIQUES DES PAYS-BAS-JOURNAL OF THE ROYAL NETHERLANDS CHEMICAL SOCIETY, 1958, 77 (11): : 1135 - 1137
  • [49] Analytical Ultracentrifuge and Its Utilization in Biochemical Laboratory
    Vanek, Ondrej
    Bezouska, Karel
    CHEMICKE LISTY, 2010, 104 (12): : 1155 - 1162
  • [50] Analytical ultracentrifuge study of micellization of surfactant mixtures
    Lu, Shaohua
    Somasundaran, P.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231