Validity of the appropriateness evaluation protocol

被引:0
|
作者
Peiro, S
Meneu, R
Rosello, ML
Portella, E
CarbonellSanchis, R
Fernandez, C
Lazaro, G
Llorens, MA
MartinezMas, E
Moreno, E
Ruano, M
Rincon, A
Vila, M
机构
[1] HOSP SAGUNTO, SERV ORL, SAGUNTO, SPAIN
[2] HOSP DR PESET, SERV GINECOL & OBSTET, VALENCIA, SPAIN
[3] HOSP GANDIA, SERV CIRUGIA GEN, VALENCIA, SPAIN
[4] HOSP DR PESET, SERV MED DIGEST, VALENCIA, SPAIN
[5] HOSP UNIV LA FE, SERV MED INTENS, VALENCIA, SPAIN
[6] HOSP UNIV LA FE, SERV CARDIOL, VALENCIA, SPAIN
[7] HOSP GEN GASTELLON, SERV ANETESIOL & REANIMAC, Castellon de La Plana, SPAIN
来源
MEDICINA CLINICA | 1996年 / 107卷 / 04期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The study was carried out in order to assess the inter-observer reliability and validity in respect of clinical appraisal given by the Appropriateness Evaluation Protocol (AEP), in the context of the Spanish Public Hospital System. MATERIAL ANO METHOD: In order to assess the reliability a total of 614 hospital stays chosen at random from 56 hospital admissions were independently analysed by three reviewers (two doctors and one nurse). In order to assess the validity, the findings obtained by the nurse were compared with the majority opinion given by the 7 hospital specialists in respect of each of hospital stays under evaluation. As part of the analytical procedure, indices for observed agreement, and specific agreement were calculated, as well as the Kappa statistic, all forming of various random samples of 614 hospital stays. in order to assess the predictive validity of the AEP, its sensitivity, specificity and predictive values were all measured against the majority clinical judgement. RESULTS: The study exhibited a high degree of inter-observer reliability (specific agreement > 64%, kappa > 0.75) and a reasonable validity in comparison with the consensus of opinions formed by a least 4 or 5 of its 7 clinical reviewers (specific agreement > 61%, kappa > 0.64), these values decreasing notably when the consensus of 6 or 7 of the reviewers was required. The AEP revealed a high degree of sensitivity and a low degree of specificity in comparison with the majority clinical assessment, thus minimising the occurrence of false results when the stay was regarded as appropriate, and producing false negatives (appropriate hospital stays regarded as inappropriate) varying in degree from moderate to very high. CONCLUSIONS: The results showing high reliability and moderate validity regarding clinical assessment shows the AEP to be a useful instrument in the sifting-out of inappropriate use of hospitalisation, although they do not allow a definitive judgement to be made concerning the efficiency of hospital services nor judgements regarding individual cases.
引用
收藏
页码:124 / 129
页数:6
相关论文
共 50 条
  • [41] Assessing the necessity of hospital stay by means of the Appropriateness Evaluation Protocol: not quite a different perspective
    Smeets, P
    Panis, L
    Verheggen, F
    Pop, P
    INTERNATIONAL JOURNAL FOR QUALITY IN HEALTH CARE, 2001, 13 (04) : 345 - 346
  • [42] Assessing inappropriate hospital stay in internal medicine using the Dutch appropriateness evaluation protocol
    Panis, LJGG
    Verheggen, FWSM
    Pop, P
    Prins, MH
    INTERNATIONAL JOURNAL FOR QUALITY IN HEALTH CARE, 2002, 14 (05) : 431 - 432
  • [43] A qualitative evaluation of the appropriateness, validity, acceptability, feasibility and interpretability of the Bristol Impact of Hypermobility (BIoH) questionnaire
    Manns, Sarah
    Cramp, Fiona
    Lewis, Rachel
    Clark, Emma M.
    Palmer, Shea
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2018, 38 : 69 - 76
  • [44] Protocol for the Evaluation of Speech Intelligibility in Dysarthrias: Evidence of Reliability and Validity
    Barreto, Simone dos Santos
    Ortiz, Karin Zazo
    FOLIA PHONIATRICA ET LOGOPAEDICA, 2015, 67 (04) : 212 - 218
  • [45] Expanded protocol of orofacial myofunctional evaluation with scores: Validity and reliability
    de Felicio, Claudia Maria
    Folha, Gislaine Aparecida
    Pimenta Ferreira, Claudia Lucia
    Magalhaes Medeiros, Ana Paula
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2010, 74 (11) : 1230 - 1239
  • [46] The hospital appropriateness evaluation protocol in elderly patients:: a technique to evaluate admission and hospital stay
    Sanchez-Garcia, Sergio
    Juarez-Cedillo, Teresa
    Mould-Quevedo, Joaquin Federico
    Garcia-Gonzalez, Jose Juan
    Contreras-Hernandez, Iris
    Espinel-Bermudez, Maria Claudia
    Hernandez-Hernandez, Dulce Maria
    Garduno-Espinosa, Juan
    Garcia-Pena, Carmen
    SCANDINAVIAN JOURNAL OF CARING SCIENCES, 2008, 22 (02) : 306 - 313
  • [47] A study of admissions and inpatients over the Christmas period using the appropriateness evaluation protocol (AEP)
    Henshaw, DJE
    Pollock, LM
    Rai, GS
    Gluck, TA
    ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2000, 31 (01) : 77 - 83
  • [48] Computerized protocol of orofacial myofunctional evaluation with scores: usability and validity
    de Felicio, Claudia Maria
    Folha, Gislaine Aparecida
    Gaido, Alice Stahl
    Mancine Dantas, Marcio de Mendonca
    de Azevedo-Marques, Paulo Mazzoncini
    CODAS, 2014, 26 (04): : 322 - 327
  • [49] Assessment of prolonged hospital stay attributable to surgical site infections using appropriateness evaluation protocol
    Merle, V
    Germain, JM
    Chamouni, P
    Daubert, H
    Froment, L
    Michot, F
    Teniere, P
    Czernichow, P
    AMERICAN JOURNAL OF INFECTION CONTROL, 2000, 28 (02) : 109 - 115
  • [50] Strategies to improve the flow of admissions and hospital stays: A Delphi study of an adaptation of the Appropriateness Evaluation Protocol
    Morillo-Rodriguez, A.
    Alonso-Fernandez, S.
    Modol Deltell, J. M.
    Soldevila Madorell, B.
    Benito-Aracil, Ll.
    Pares, D.
    REVISTA CLINICA ESPANOLA, 2023, 223 (05): : 270 - 280