Minimally invasive stabilisation of posterior pelvic ring instabilities with pedicle screws connected to a transverse rod

被引:22
|
作者
Wang, Hu [1 ]
Fu, Ya-hui [1 ]
Ke, Chao [1 ]
Zhuang, Yan [1 ]
Zhang, Kun [1 ]
Wei, Xing [1 ]
Li, Zhong [1 ]
Lei, Jin-lai [1 ]
Zhang, Bin-fei [1 ]
Liu, Ping [1 ]
机构
[1] Xi An Jiao Tong Univ, HongHui Hosp, Dept Pelv & Acetabular Surg, Xian, Shaanxi, Peoples R China
关键词
Minimally invasive surgery; Posterior pelvic ring stabilisation; Sacral fractures; SACRAL FRACTURES; ILIOSACRAL SCREWS; C INJURIES; FOLLOW-UP; FIXATION; DISLOCATIONS;
D O I
10.1007/s00264-017-3714-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The goal was to evaluate the clinical outcomes, quality of reduction and complications of pelvic fractures treated by minimally invasive stabilisation of posterior pelvic ring instabilities with pedicle screws connected to a transverse rod. Retrospective analysis of prospectively collected data in a consecutive patient series with pelvic fractures treated by minimally invasive stabilisation of posterior pelvic ring instabilities with pedicle screws between January 2010 and January 2016. The functional outcomes evaluated by Majeed scores, and fracture reduction results were evaluated using the Tornetta and Matta standard. As well as recording the duration of the surgical procedure, intraoperative blood loss, the times of intra-operative fluoroscopy and complications. A total of 29 patients (15 men and 14 women; age range, 21-72 years; mean, 40.8 years) could be followed-up after an average of 38.2 +/- 21.3 months (range, 12-84 months). According to the AO/OTA classification, there were 24 patients with B2 injury and five patients with C1 injury of the pelvic ring. For the sacral fractures, according to Denis classification, four cases were zone I fractures and 25 cases were zone II fractures. The duration of the surgical procedure, intra-operative blood loss and the times of intra-operative fluoroscopic of the posterior-ring surgical procedure was 28.2 +/- 4.6 minutes (range, 20-38 minutes), 46.7 +/- 4.9 ml (range, 39-56 ml), and 13.1 +/- 1.6 seconds (range, 10-17 seconds) respectively. Posterior-ring fracture reduction was excellent in 11 patients and 15 were good, three cases were fair; the excellent and good rate was 89.7% (26/29). At the final follow-up, the function result was rated as excellent in ten cases, good in 16, fair in three, and poor in zero cases; the excellent and good rate was 89.7% (26/29). There was no incision infection, intra-operative neurovascular injury, pedicle screw loose or breakage, and non-union of the posterior arch did not occur. Two patients requested removal of the fixator: one patient with breakage of the anterior pelvic ring internal fixator, and the pedicle screw was also taken out in the same operative session; another one with moderate pain on the posterior pelvic ring. Minimally invasive stabilisation of posterior-pelvic-ring instabilities with pedicle screw connected to a transverse rod may be a good alternative to sacroiliac screw fixation because it is quick, safe and associated with a good functional outcome; thus being a useful option in patients who do not qualify for sacroiliac screw fixation.
引用
收藏
页码:681 / 686
页数:6
相关论文
共 50 条
  • [21] Treatment of posterior pelvic ring injuries with minimally invasive percutaneous plate osteosynthesis
    Tang Hao
    Yang Changwei
    Zhang Qiulin
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (05) : 1435 - 1439
  • [22] Minimally Invasive Surgery for Unstable Pelvic Ring Fractures: Transiliac Rod and Screw Fixation
    Toda, Kazukiyo
    Yagata, Yukihisa
    Kikuchi, Takeshi
    Takigawa, Tomoyuki
    Ito, Yasuo
    ACTA MEDICA OKAYAMA, 2020, 74 (01) : 27 - 32
  • [23] Anterior and Posterior Lumbar Interbody Fusion With Percutaneous Pedicle Screws Comparison to Muscle Damage and Minimally Invasive Techniques
    Dickerman, Rob D.
    East, John W.
    Winters, Karl
    Tackett, Jennifer
    Hajovsky-Pietla, Annette
    SPINE, 2009, 34 (25) : E923 - E925
  • [24] Erratum to: Minimally invasive PLIF with divergent, cortical trajectory pedicle screws
    Pedro Berjano
    Marco Damilano
    Maryem Ismael
    Carlo Formica
    Diego Garbossa
    European Spine Journal, 2015, 24 : 2096 - 2096
  • [25] Minimally invasive internal fixator for unstable pelvic ring injuries with a pedicle screw–rod system: a retrospective study of 23 patients after 13.5 months
    Xingyi Hua
    Shuang G. Yan
    Yiliang Cui
    Zongsheng Yin
    Anna J. Schreiner
    Florian Schmidutz
    Archives of Orthopaedic and Trauma Surgery, 2019, 139 : 489 - 496
  • [26] Triangular vertebropelvine stabilisation of unstable posterior pelvic ring fractures
    Tiemann, AH
    Schmidt, C
    Josten, C
    ZENTRALBLATT FUR CHIRURGIE, 2003, 128 (03): : 202 - 208
  • [27] Evaluation of robot-guided minimally invasive implantation of 2067 pedicle screws
    Keric, Naureen
    Doenitz, Christian
    Haj, Amer
    Rachwal-Czyzewicz, Izabela
    Renovanz, Mirjam
    Wesp, Dominik M. A.
    Boor, Stephan
    Conrad, Jens
    Brawanski, Alexander
    Giese, Alf
    Kantelhardt, Sven R.
    NEUROSURGICAL FOCUS, 2017, 42 (05)
  • [28] Closed Reduction and Minimally Invasive Fixation for the Treatment of Bilateral Displaced Posterior Pelvic Ring Disruption
    Wang, Zhen
    Xu, Zhe
    Xiang, Peng-hui
    Gu, Mei-qi
    Zhang, Rui
    Chen, Hua
    He, Li
    Yi, Cheng-la
    CURRENT MEDICAL SCIENCE, 2025, 45 (01) : 137 - 145
  • [29] Minimally invasive internal fixator for unstable pelvic ring injuries with a pedicle screw-rod system: a retrospective study of 23 patients after 13.5 months
    Hua, Xingyi
    Yan, Shuang G.
    Cui, Yiliang
    Yin, Zongsheng
    Schreiner, Anna J.
    Schmidutz, Florian
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (04) : 489 - 496
  • [30] Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems
    Abumi, K
    Takada, T
    Shono, Y
    Kaneda, K
    Fujiya, M
    SPINE, 1999, 24 (14) : 1425 - 1434