Lung ultrasound allows the diagnosis of weaning-induced pulmonary oedema

被引:60
|
作者
Ferre, Alexis [1 ,2 ]
Guillot, Max [1 ,2 ]
Lichtenstein, Daniel [3 ]
Meziere, Gilbert [4 ]
Richard, Christian [1 ,2 ]
Teboul, Jean-Louis [1 ,2 ]
Monnet, Xavier [1 ,2 ]
机构
[1] Univ Paris Saclay, INSERM, UMR S 999, Univ Paris Sud,Fac Med, Le Kremlin Bicetre, France
[2] Hop Bicetre, AP HP, Serv Med Intens Reanimat, 78 Rue Gen Leclerc, F-94270 Le Kremlin Bicetre, France
[3] Hop Ambroise Pare, AP HP, Serv Reanimat Med, Paris, France
[4] Ctr Hosp Gaston Ramon, Serv Reanimat Polyvalente, Sens, France
关键词
Heart failure; Interstitial oedema; Heart-lung interactions; Extravascular lung water; Mechanical ventilation; NATRIURETIC PEPTIDE; THORACIC ULTRASOUND; CARDIAC DYSFUNCTION; TRIAL; PROTOCOL; FAILURE; WATER;
D O I
10.1007/s00134-019-05573-6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Rationale Detecting weaning-induced pulmonary oedema (WIPO) is important because its treatment might prompt extubation. For this purpose, lung ultrasound might be an attractive tool, since it demonstrates pulmonary oedema through the appearance of B-lines.Objectives To test the ideal profile (increase in the number of B-lines) for diagnosing WIPO.Methods Before and at the end of 62 spontaneous breathing trials (SBT) performed in 42 patients, we prospectively assessed lung ultrasound on four anterior chest wall points. B-lines were counted before and at the end of SBT. We looked for the threshold of B-line increase (Delta-B-lines) that provided the best diagnostic accuracy, compared to the reference diagnosis of WIPO established by experts blinded to lung ultrasound.Results SBT failed in 33 cases. WIPO occurred in 17 cases and all failed. The best diagnostic accuracy was reached with a Delta-B-lines6. Among WIPO, the number of B-lines increased by 6 in 15 cases (including 13 cases with an increase of 8 B-lines). Among the 16 cases with SBT failure but without WIPO, the Delta-B-lines was 6 in two cases. Among the 33 cases with SBT failure, this profile diagnosed WIPO with a sensitivity of 88% (64-98) and a specificity of 88% (62-98) [area under the receiver operating characteristic curve 0.91 (0.75-0.98)]. Among the 29 cases with SBT success, a Delta-B-lines 6 occurred in two cases.Conclusions This study suggests that a Delta-B-lines 6 on four anterior points allows the diagnosis of WIPO with the best accuracy. This should be confirmed in larger populations.
引用
收藏
页码:601 / 608
页数:8
相关论文
共 50 条
  • [41] Hematologic, Metabolite and Hormone Responses to Weaning-Induced Stress in Foals of Different Breeds
    Qureshi, Anas Sarwar
    Yaqoob, Fazeela
    Enbergs, Heinrich
    PAKISTAN VETERINARY JOURNAL, 2013, 33 (04) : 500 - 504
  • [42] Diagnosis and treatment of acute pulmonary oedema
    Bomassi, É
    POINT VETERINAIRE, 2003, 34 (233): : 36 - +
  • [43] Lung ultrasound for the cardiologist - a basic application: The B-profile of the Bedside Lung Ultrasound in Emergencies protocol for diagnosing haemodynamic pulmonary oedema
    Lichtenstein, Daniel A.
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2020, 113 (8-9) : 489 - 491
  • [44] Lifelong Adaptation of Gastric Cell Proliferation and Mucosa Structure to Early Weaning-Induced Effects
    Mesquita da Silva, Kethleen
    Rattes, Isadora Campos
    Pereira, Gizela Maria Agostini
    Gama, Patricia
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [45] RELATIVE DEPLETION OF LUNG HISTAMINE IN EXPERIMENTAL PULMONARY OEDEMA INDUCED BY CHLOROPICRIN AND VAGOTOMY
    DHAR, HL
    ARORA, RB
    LIFE SCIENCES, 1962, (07) : 309 - 313
  • [46] PULMONARY-FUNCTION MONITORING ALLOWS EARLY DIAGNOSIS OF LUNG REJECTION IN HEART-LUNG TRANSPLANTATION
    OTULANA, BA
    HIGENBOTTAM, TW
    SCOTT, JP
    CLELLAND, C
    HUTTER, JA
    WALLWORK, J
    THORAX, 1988, 43 (10) : P807 - P807
  • [47] Swimming-induced pulmonary oedema an uncommon condition diagnosed with POCUS ultrasound.
    Alonso, Joaquin Valle
    Chowdhury, Motiur
    Borakati, Raju
    Gankande, Upali
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2017, 35 (12): : 1986.e3 - 1986.e4
  • [48] Exogenous GLP-2 has limited effects on weaning-induced intestinal adaptation in piglets
    Le Huerou-Luron, I
    Petersen, YM
    Hartmann, B
    Holst, JJ
    Sangild, PT
    GASTROENTEROLOGY, 2002, 122 (04) : A380 - A381
  • [49] Lung Ultrasound as an Adjunct to Pulse Oximetry and Respiratory Symptoms in the Diagnosis of Freediving-Induced Pulmonary Syndrome
    Yu, Elaine
    Silva, Fernando
    Lussier, Anna
    Lindholm, Peter
    WILDERNESS & ENVIRONMENTAL MEDICINE, 2024, 35 (04) : 409 - 416
  • [50] THE EFFECT OF PULMONARY CONGESTION AND OEDEMA ON LUNG COMPLIANCE
    HUGHES, R
    MAY, AJ
    WIDDICOMBE, JG
    JOURNAL OF PHYSIOLOGY-LONDON, 1958, 142 (02): : 306 - 313