QUALITY ASSURANCE PROCEDURE FOR SRS AND SRT TREATMENTS

被引:0
|
作者
Meijers, Arturs [1 ]
Plaude, Sandija [1 ]
Utehina, Olga [1 ]
Popovs, Sergejs [1 ]
机构
[1] Riga E Univ Hosp, Riga, Latvia
关键词
Quality assurance; stereotactic radiosurgery; stereotactic radiotherapy; IONIZATION CHAMBERS; RADIOSURGERY; ARC;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Radiosurgical treatments are often highly complex in terms of dose modulation, which is achieved applying advanced treatment delivery techniques (IMRT, VMAT etc.). However due to dose delivery in single or a few fractions, dose delivery requires higher precision and accuracy compared to fractionated treatments. Therefor complex quality assurance procedure, which includes point dose, dose plane measurements and Winston-Lutz test, has been developed. Such procedure has been implemented in Riga East University Hospital.
引用
收藏
页码:69 / 72
页数:4
相关论文
共 50 条
  • [1] Quality Assurance for SRS/SRT IMRT
    Guo, F.
    Chen, Z.
    Deng, J.
    Fan, Y.
    Nath, R.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2764 - +
  • [2] Evaluation of the intrafraction motion in SRT-SRS treatments
    Granero Cabanero, D.
    Almendros Blanco, P.
    Hernandez Machancoses, A.
    Vicedo Gonzalez, A.
    Garcia Hernandez, T.
    Brualla Gonzalez, L.
    Perruca Salvador, F.
    Salvador Montano, A.
    Rosello Ferrando, J.
    Lopez Torrecilla, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S672 - S672
  • [3] Initial Experience in Comparing IQM and SRS MapCHECK for Single ISO Multiple Mets Brain SRS/SRT Plan Quality Assurance
    Liang, Y.
    Pavord, D.
    Lee, H.
    Horne, Z.
    Wegner, R.
    Karlovits, S.
    Sohn, J.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [4] The Development of Quality Assurance Methods for Trajectory based Cranial SRS Treatments
    Wilson, B.
    Teke, T.
    Duzenli, C.
    Gete, E.
    [J]. MEDICAL PHYSICS, 2014, 41 (08) : 29 - 29
  • [5] Retrospective analysis of portal dosimetry pre-treatment quality assurance of intracranial SRS/SRT VMAT treatment plans
    Osei, Ernest
    Graves, Sarah
    Darko, Johnson
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (04) : 540 - 552
  • [6] Safety and Quality Assurance in SRS and SBRT
    Jaffray, D.
    Benedict, S.
    Solberg, T.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [7] Cranial SRS/SRT
    Yenice, K.
    Solberg, T.
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3799 - +
  • [8] Machine Specific Quality Assurance Procedure for Stereotactic Treatments with Dynamic Couch Rotations
    Wilson, B.
    Gete, E.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2955 - 2955
  • [9] Quality Assurance for a Commercial Automated VMAT SRS System
    Yuan, Y.
    Sullivan, R.
    Popple, R.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E836 - E836
  • [10] Machine-specific quality assurance procedure for stereotactic treatments with dynamic couch rotations
    Wilson, Byron
    Gete, Ermias
    [J]. MEDICAL PHYSICS, 2017, 44 (12) : 6529 - 6537