Characterization and Corrosion Resistance of Anodic Electrodeposited Titanium Oxide/Phosphate Films on Ti-20Nb-10Zr-5Ta Bioalloy

被引:3
|
作者
Popa, Monica [1 ]
Vasilescu, Cora [1 ]
Drob, Silviu I. [1 ]
Osiceanu, Petre [1 ]
Anastasescu, Mihai [1 ]
Calderon-Moreno, Jose M. [1 ]
机构
[1] Acad Romana, Inst Phys Chem Ilie Murgulescu, Bucharest 060021, Romania
关键词
surface functionalization; galvanostatic deposition; deposition from simulated human fluids; depth profile XPS; corrosion; RINGERS LACTATE SOLUTION; SIMULATED BODY-FLUIDS; ELECTROCHEMICAL-BEHAVIOR; OXIDE FILMS; HYDROXYAPATITE; PHOSPHATE; ALLOYS; TI; DEPOSITION; TI-6AL-4V;
D O I
10.5935/0103-5053.20130146
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this work, the anodic galvanostatic electrodeposition of an oxidation film containing phosphates on Ti-20Nb-10Zr-5Ta alloy from orthophosphoric acid solution is presented. Its composition was determined by X-ray diffractometry (XRD), Fourier transform infrared spectroscopy (FTIR) and Raman micro-spectroscopy, and its topography by atomic force microscopy (AFM). The corrosion resistance of the coated alloy in simulated human fluid (by linear polarization method and monitoring of open circuit potentials, corresponding open circuit potential gradients) as well as the characterization of the coating (by Raman spectroscopy and depth profile X-ray photoelectron spectroscopy (XPS)) deposited in a period of 300 h soaking in simulated human body fluid were studied. The electrodeposited film was composed of amorphous titanium dioxide and contained phosphate groups. The corrosion resistance of the coated Ti-20Nb-10Zr-5Ta alloy in neutral and alkaline Ringer's solutions was higher than that of the bare alloy due to the protective properties of the electrodeposited film. The corrosion parameters improved over time as result of the thickening of the surface film by the deposition from the physiological solution. The deposited coating presented a variable composition in depth: at the deeper layer nucleated nanocrystalline hydroxyapatite and at the outer layer amorphous calcium phosphate.
引用
收藏
页码:1123 / 1134
页数:12
相关论文
共 50 条
  • [31] Characterization of the Ti-10Nb-10Zr-5Ta Alloy for Biomedical Applications. Part 2: Wettability, Tribological Performance and Biocompatibility
    Braic, V.
    Balaceanu, M.
    Braic, M.
    Vitelaru, C.
    Titorencu, I.
    Pruna, V.
    Parau, A. C.
    Fanara, C.
    Vladescu, A.
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2014, 23 (01) : 326 - 332
  • [32] Fatigue and corrosion resistance of low modulus Ti-35Nb-7Zr-5Ta-0.35O beta Ti alloy for orthopedic implant applications
    Vishnu, Jithin
    Manivasagam, Geetha
    Rao, Nageswara
    Rack, H. J.
    MATERIALS TODAY COMMUNICATIONS, 2022, 31
  • [33] Effects of sealing process on corrosion resistance and roughness of anodic films of titanium alloy Ti-10V-2Fe-3Al
    刘建华
    吴量
    于美
    李松梅
    吴国龙
    Journal of Central South University of Technology, 2011, 18 (06) : 1795 - 1801
  • [34] Effects of sealing process on corrosion resistance and roughness of anodic films of titanium alloy Ti-10V-2Fe-3Al
    Jian-hua Liu
    Liang Wu
    Mei Yu
    Song-mei Li
    Guo-long Wu
    Journal of Central South University of Technology, 2011, 18 : 1795 - 1801
  • [35] Effects of sealing process on corrosion resistance and roughness of anodic films of titanium alloy Ti-10V-2Fe-3Al
    Liu Jian-hua
    Wu Liang
    Yu Mei
    Li Song-mei
    Wu Guo-long
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2011, 18 (06): : 1795 - 1801
  • [36] Influence of Molybdenum on the Microstructure, Mechanical Properties and Corrosion Resistance of Ti20Ta20Nb20(ZrHf)20-xMox (Where: x=0, 5, 10, 15, 20) High Entropy Alloys
    Glowka, Karsten
    Zubko, Maciej
    Swiec, Pawel
    Prusik, Krystian
    Szklarska, Magdalena
    Chrobak, Dariusz
    Labar, Janos L.
    Stroz, Danuta
    MATERIALS, 2022, 15 (01)
  • [37] Influence of Hafnium Addition on the Microstructure, Microhardness and Corrosion Resistance of Ti20Ta20Nb20(ZrMo)20-xHfx (where x=0, 5, 10, 15 and 20 at.%) High Entropy Alloys
    Glowka, Karsten
    Zubko, Maciej
    Gebura, Sandra
    Swiec, Pawel
    Prusik, Krystian
    Szklarska, Magdalena
    Stroz, Danuta
    MATERIALS, 2023, 16 (04)
  • [38] Investigation of static properties of medical alloys Ti-(20-30)Nb-(10-13)Ta-5Zr
    Sergienko, K. V.
    Sevost'yanov, M. A.
    Konushkin, S. V.
    Nasakina, E. O.
    Baikin, A. S.
    Shatova, L. A.
    Kolmakov, A. G.
    THIRD INTERNATIONAL YOUTH SCIENTIFIC FORUM WITH INTERNATIONAL PARTICIPATION NEW MATERIALS, 2018, 347
  • [39] Optimizing strength and corrosion resistance of the metastable β-alloy Ti-35Nb-7Zr-5Ta alloy by equal-channel angular pressing
    Silva, R.
    Silva, J.
    Viana, C. C.
    Afonso, C. R. M.
    Hammer, P.
    Magalhaes, D. C. C.
    Plaine, A. H.
    Rovere, C. A. D.
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2025, 35 : 2055 - 2067
  • [40] Effect of Zr addition on mechanical properties and corrosion behavior of Ti-6Al-7Nb- x Zr ( x=0, 5, 10, 15, 20 wt%) alloy
    Lu, Haoran
    Tang, Yihao
    Shi, Heyang
    Li, Bo
    Ji, Pengfei
    Xu, Zuo
    Liang, Shunxing
    Zhang, Junsong
    Zhang, Shuzhi
    Zhang, Xinyu
    Liu, Riping
    JOURNAL OF ALLOYS AND COMPOUNDS, 2024, 998