Characterization and Corrosion Resistance of Anodic Electrodeposited Titanium Oxide/Phosphate Films on Ti-20Nb-10Zr-5Ta Bioalloy

被引:3
|
作者
Popa, Monica [1 ]
Vasilescu, Cora [1 ]
Drob, Silviu I. [1 ]
Osiceanu, Petre [1 ]
Anastasescu, Mihai [1 ]
Calderon-Moreno, Jose M. [1 ]
机构
[1] Acad Romana, Inst Phys Chem Ilie Murgulescu, Bucharest 060021, Romania
关键词
surface functionalization; galvanostatic deposition; deposition from simulated human fluids; depth profile XPS; corrosion; RINGERS LACTATE SOLUTION; SIMULATED BODY-FLUIDS; ELECTROCHEMICAL-BEHAVIOR; OXIDE FILMS; HYDROXYAPATITE; PHOSPHATE; ALLOYS; TI; DEPOSITION; TI-6AL-4V;
D O I
10.5935/0103-5053.20130146
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this work, the anodic galvanostatic electrodeposition of an oxidation film containing phosphates on Ti-20Nb-10Zr-5Ta alloy from orthophosphoric acid solution is presented. Its composition was determined by X-ray diffractometry (XRD), Fourier transform infrared spectroscopy (FTIR) and Raman micro-spectroscopy, and its topography by atomic force microscopy (AFM). The corrosion resistance of the coated alloy in simulated human fluid (by linear polarization method and monitoring of open circuit potentials, corresponding open circuit potential gradients) as well as the characterization of the coating (by Raman spectroscopy and depth profile X-ray photoelectron spectroscopy (XPS)) deposited in a period of 300 h soaking in simulated human body fluid were studied. The electrodeposited film was composed of amorphous titanium dioxide and contained phosphate groups. The corrosion resistance of the coated Ti-20Nb-10Zr-5Ta alloy in neutral and alkaline Ringer's solutions was higher than that of the bare alloy due to the protective properties of the electrodeposited film. The corrosion parameters improved over time as result of the thickening of the surface film by the deposition from the physiological solution. The deposited coating presented a variable composition in depth: at the deeper layer nucleated nanocrystalline hydroxyapatite and at the outer layer amorphous calcium phosphate.
引用
收藏
页码:1123 / 1134
页数:12
相关论文
共 50 条
  • [1] Deposition, Characterization, and Corrosion Resistance of Nanocrystalline Bioactive Hydroxyapatite Ceramic Coating on New Ti-20Nb-10Zr-5Ta Alloy
    Popa, Monica
    Vasilescu, Ecaterina
    Drob, Paula
    Popa, Mihai Vasile
    Moreno, Jose Maria Calderon
    Vasilescu, Cora
    Drob, Silviu Iulian
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2012, 95 (12) : 3807 - 3814
  • [2] Electrochemical Behaviour of Ti-20Nb-10Zr-5Ta Alloy in Simulated Physiological Fluids after Anodic Electrolytic Oxidation
    Popa, Monica
    Vasilescu, Cora
    Drob, Silviu Iulian
    Moreno, Jose M. Calderon
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (04): : 5287 - 5298
  • [3] Electrochemical properties, chemical composition and thickness of passive film formed on novel Ti-20Nb-10Zr-5Ta alloy
    Milosev, Ingrid
    Zerjav, Gregor
    Moreno, Jose Maria Calderon
    Popa, Monica
    ELECTROCHIMICA ACTA, 2013, 99 : 176 - 189
  • [4] Microstructure, mechanical, and anticorrosive properties of a new Ti-20Nb-10Zr-5Ta alloy based on nontoxic and nonallergenic elements
    Monica Popa
    Ecaterina Vasilescu
    Paula Drob
    Doina Raducanu
    Jose Maria Calderon Moreno
    Steliana Ivanescu
    Cora Vasilescu
    Silviu Iulian Drob
    Metals and Materials International, 2012, 18 : 639 - 645
  • [5] Microstructure, mechanical, and anticorrosive properties of a new Ti-20Nb-10Zr-5Ta alloy based on nontoxic and nonallergenic elements
    Popa, Monica
    Vasilescu, Ecaterina
    Drob, Paula
    Raducanu, Doina
    Moreno, Jose Maria Calderon
    Ivanescu, Steliana
    Vasilescu, Cora
    Drob, Silviu Iulian
    METALS AND MATERIALS INTERNATIONAL, 2012, 18 (04) : 639 - 645
  • [6] Quaternary Ti-20Nb-10Zr-5Ta alloy during immersion in simulated physiological solutions: formation of layers, dissolution and biocompatibility
    Milosev, Ingrid
    Hmeljak, Julija
    Zerjav, Gregor
    Coer, Andrej
    Moreno, Jose Maria Calderon
    Popa, Monica
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2014, 25 (04) : 1099 - 1114
  • [7] Characterization of the Ti-10Nb-10Zr-5Ta Alloy for Biomedical Applications. Part 1: Microstructure, Mechanical Properties, and Corrosion Resistance
    Vladescu, A.
    Braic, V.
    Balaceanu, M.
    Braic, M.
    Parau, A. C.
    Ivanescu, S.
    Fanara, C.
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2013, 22 (08) : 2389 - 2397
  • [8] Characterization of the Ti-10Nb-10Zr-5Ta Alloy for Biomedical Applications. Part 1: Microstructure, Mechanical Properties, and Corrosion Resistance
    A. Vladescu
    V. Braic
    M. Balaceanu
    M. Braic
    A. C. Parau
    S. Ivanescu
    C. Fanara
    Journal of Materials Engineering and Performance, 2013, 22 : 2389 - 2397
  • [9] Corrosion resistance and cytocompatibility of Ti-20Zr-10Nb-4Ta alloy surface modified by a focused fiber laser
    Xue, Xianda
    Ma, Chengpeng
    An, Hongjuan
    Li, Yan
    Guan, Yingchun
    SCIENCE CHINA-MATERIALS, 2018, 61 (04) : 516 - 524
  • [10] ELECTRICAL PROPERTIES OF ANODIC OXIDE FILMS OF TA, NB, ZR, TI, W, AND V FORMED BY ION-CATHODE METHOD
    HUSTED, D
    GRUSS, L
    MACKUS, T
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1971, 118 (12) : 1989 - +