Mechanisms and management of inappropriate therapy in subcutaneous implantable cardioverter defibrillators

被引:6
|
作者
Karnik, Ankur A. [1 ]
Helm, Robert H. [1 ]
Monahan, Kevin M. [1 ]
机构
[1] Boston Med Ctr, Dept Med, Div Cardiol, Electrophysiol & Arrhythmia Serv, Boston, MA USA
关键词
hypertrophic cardiomyopathy (HCM); ICD (implantable cardioverter defibrillators) shock; inappropriate therapy; oversensing; subcutaneous ICD (S-ICDs); HYPERTROPHIC CARDIOMYOPATHY; SHOCKS; RISK; PERFORMANCE; PREDICTORS; EFFORTLESS;
D O I
10.1111/jce.13831
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Subcutaneous implantable cardioverter defibrillators (S-ICDs) provide reliable defibrillation and have enhanced supraventricular tachycardia discrimination and fewer infection rates compared with traditional transvenous systems. However, inappropriate shocks remain a frequent problem. Herein, we review the various mechanisms of these inappropriate therapies, some of which are unique to S-ICDs, and propose an algorithm for preventing recurrences. Proper screening of preimplants is essential to help minimize inappropriate therapies, but patients with hypertrophic cardiomyopathy, Brugada syndrome, and arrhythmogenic right ventricular cardiomyopathy are at particular risk and may require additional measures.
引用
收藏
页码:402 / 409
页数:8
相关论文
共 50 条
  • [41] Implantable cardioverter defibrillators
    Shah, CP
    Thakur, RK
    Xie, BY
    Hoon, VK
    EMERGENCY MEDICINE CLINICS OF NORTH AMERICA, 1998, 16 (02) : 463 - +
  • [42] Implantable cardioverter defibrillators
    Cardiac Pacemakers, Inc, St. Paul, United States
    Proc IEEE, 3 (468-479):
  • [43] Implantable Cardioverter Defibrillators
    不详
    MEDICAL LETTER ON DRUGS AND THERAPEUTICS, 2009, 51 (1304): : 6 - 7
  • [44] Implantable cardioverter defibrillators
    Harris, Stuart
    Dhinoja, Mehul
    CLINICAL MEDICINE, 2007, 7 (04) : 397 - 400
  • [45] Implantable cardioverter defibrillators
    Warren, JA
    Dreher, RD
    Jaworski, RV
    Putzke, JJ
    Russie, RJ
    PROCEEDINGS OF THE IEEE, 1996, 84 (03) : 468 - 479
  • [46] Appropriate and inappropriate therapy in patients with single- or multi-chamber implantable cardioverter-defibrillators
    Burger, Achim Leo
    Schmidinger, Herwig
    Ristl, Robin
    Pezawas, Thomas
    HELLENIC JOURNAL OF CARDIOLOGY, 2020, 61 (06) : 421 - 427
  • [47] Inappropriate shocks in single-chamber and subcutaneous implantable cardioverter-defibrillators: a systematic review and meta-analysis
    Auricchio, Angelo
    Hudnall, J. Harrison
    Schloss, Edward J.
    Sterns, Laurence D.
    Kurita, Takashi
    Meijer, Albert
    Fagan, Dedra H.
    Rogers, Tyson
    EUROPACE, 2017, 19 (12): : 1973 - 1980
  • [48] Manual vs. automatic capture management in implantable cardioverter defibrillators and cardiac resynchronization therapy defibrillators
    Murgatroyd, Francis D.
    Helmling, Erhard
    Lemke, Bernd
    Eber, Bernd
    Mewis, Christian
    van der Meer-Hensgens, Judith
    Chang, Yanping
    Khalameizer, Vladimir
    Katz, Amos
    EUROPACE, 2010, 12 (06): : 811 - 816
  • [49] Premature battery depletion of EMBLEM subcutaneous implantable cardioverter-defibrillators
    Ip, James E.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (03) : 565 - 567
  • [50] Clinical Experience of Subcutaneous and Transvenous Implantable Cardioverter Defibrillators in Children and Teenagers
    Pettit, Stephen J.
    Mclean, Andrew
    Colquhoun, Ian
    Connelly, Derek
    McLeod, Karen
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2013, 36 (12): : 1532 - 1535