Reference values for peak flow and FEV1 variation in healthy schoolchildren using home spirometry

被引:19
|
作者
Brouwer, A. F. J. [1 ,2 ]
Roorda, R. J. [2 ,3 ]
Duiverman, E. J. [1 ]
Brand, P. L. P. [2 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Paediat Pulmonol, Beatrix Childrens Hosp, NL-9700 VB Groningen, Netherlands
[2] Princess Amalia Childrens Clin, Isala Clin, Zwolle, Netherlands
[3] St Anna Care Grp, Geldrop, Netherlands
关键词
Forced expiratory volume in one second; home spirometry; peak flow variation; reference values; schoolchildren;
D O I
10.1183/09031936.00148107
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Current reference values for diurnal peak flow variation in healthy children (median 8.2%; 95th percentile 31%) are so high that considerable overlap exists with those of asthmatic children. These values have been obtained using written peak flow diaries, which are unreliable. The aim of the present study was to obtain reliable reference values for the variation in peak flow and forced expiratory volume in one second (FEV1) in healthy schoolchildren using home spirometry with electronic data storage. Healthy schoolchildren (n=204; 100 males) aged 6-16 yrs measured their peak flow and FEV1 twice daily for 2 weeks using an electronic home spirometer. The variation in peak flow and FEV1 were calculated as a diurnal amplitude as a percentage of the day's mean. The mean peak flow variation was 6.2% (95th percentile 12.3%) and the mean FEV1 variation was 5.7% (95th percentile 11.8%). Using home spirometry with electronic data storage, healthy schoolchildren show considerably less peak flow and forced expiratory volume in one second variation than previously reported on the basis of written peak flow diaries. Being the 95th percentiles of the distributions in healthy children, a peak flow variation of 12.3% and an forced expiratory volume in one second variation of 11.8% are suggested as cut-off values for disease when using home spirometry.
引用
收藏
页码:1262 / 1268
页数:7
相关论文
共 50 条
  • [42] Can Serial Fev1 Identify Work-Related Asthma Cases Missed By Serial Peak Expiratory Flow?
    Henneberger, P. K.
    Cox-Ganser, J.
    Moore, V. C.
    Burge, C. B.
    Liang, X.
    Burge, P. S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [43] EVALUATION OF THE FERRARIS POCKET PEAK FLOW METER FOR THE MEASUREMENT OF PEAK EXPIRATORY FLOW-RATE (PEFR), AND FORCED EXPIRATORY VOLUME IN THE 1ST SECOND (FEV1)
    NOLAN, KM
    DORNELLY, SM
    HUGHES, DT
    STRUNIN, L
    RESPIRATORY MEDICINE, 1992, 86 (06) : 525 - 526
  • [44] COMPARISON OF PEAK EXPIRATORY FLOW-RATE AND FEV1 IN ASSESSING BRONCHOMOTOR TONE AFTER CHALLENGES WITH OCCUPATIONAL SENSITIZERS
    BERUBE, D
    CARTIER, A
    LARCHEVEQUE, J
    GHEZZO, H
    MALO, JL
    CHEST, 1991, 99 (04) : 831 - 836
  • [45] An increase in Peak Flow variability reflects T2 inflammation more than ACT or change in FEV1
    Ottewill, Ciara
    Brennan, Vincent
    Kerr, Patrick
    MacHale, Elaine
    Greene, Garrett
    Costello, Richard W.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2024, 193 : S218 - S218
  • [46] Challenges and Pitfalls of Using Repeat Spirometry Recordings in Routine Primary Care Data to Measure FEV1 Decline in a COPD Population
    Whittaker, Hannah R.
    Kiddle, Steven J.
    Quint, Jennifer K.
    PRAGMATIC AND OBSERVATIONAL RESEARCH, 2021, 12 : 119 - 130
  • [47] Cut-off value of FEV1/FEV6 to determine airflow limitation using handheld spirometry in subjects with risk of chronic obstructive pulmonary disease
    Hwang, Yong Il
    Kim, Youlim
    Rhee, Chin Kook
    Kim, Deog Kyeom
    Park, Yong Bum
    Yoo, Kwang Ha
    Jung, Ki-Suck
    Lee, Chang Youl
    KOREAN JOURNAL OF INTERNAL MEDICINE, 2021, 36 (03): : 629 - 635
  • [49] Reference values for peak expiratory flow in Indian adult population using a European Union scale peak flow meter
    Kodgule, R. R.
    Singh, V
    Dhar, R.
    Saicharan, B. G.
    Madas, S. J.
    Gogtay, J. A.
    Salvi, S. S.
    Koul, P. A.
    JOURNAL OF POSTGRADUATE MEDICINE, 2014, 60 (02) : 123 - 129
  • [50] Agreement between forced expiratory volume in the first second (FEV1) and peak expiratory flow (PEF) in severe acute asthma
    Damaraju, Vikram
    Nath, Alok
    Sehgal, Inderpaul
    Muthu, Valliappan
    Prasad, Kuruswamy
    Dhooria, Sahajal
    Aggarwal, Ashutosh
    Agarwal, Ritesh
    LUNG INDIA, 2022, 39 (05) : 484 - 487