Detection of Cardiac Abnormalities from MRI Sequences by Using a Deformable Mesh Model

被引:0
|
作者
Parages, Felipe M. [1 ]
Brankov, Jovan G. [1 ]
机构
[1] IIT, Dept Elect Engn, Chicago, IL 60616 USA
关键词
cine MRI; mesh model; motion analysis; motion estimation; myocardial torsion; tagged MRI; MOTION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work, we explore the potential of estimated ventricle motion, using a deformable mesh model (DMM), to detect cardiac pathologies such as hypertension and mitral regurgitation in MRI cardiac gated image sequences. In DMM, left ventricle motion was estimated by deforming a 3D-mesh along pixel-intensity variations of combined tagged and cine MRI sequences. Next, dense motion fields obtained from DMM were used to compute 3D torsion maps for the LV using a B-Spline model. Features extracted from the torsion maps were used for detection of hypertension and mitral regurgitation by performing Fisher Discriminant Analysis. Finally, detection performance of DMM motion was compared to other known motion-tracking approaches, such as Feature Based (FB) analysis and Unwrapped Phase Strain (SUP).
引用
收藏
页码:4028 / 4031
页数:4
相关论文
共 50 条
  • [11] Feature-adaptive motion tracking of ultrasound image sequences using a deformable mesh
    Yeung, F
    Levinson, SF
    Fu, DS
    Parker, KJ
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (06) : 945 - 956
  • [12] Spatiotemporal processing of gated cardiac SPECT images using deformable mesh modeling
    Brankov, JG
    Yang, YY
    Wernick, MN
    [J]. MEDICAL PHYSICS, 2005, 32 (09) : 2839 - 2849
  • [13] Cardiac motion tracking using a deformable 2D-mesh modeling
    Desserée, D
    Legrand, L
    Walker, P
    Lalande, A
    Brunotte, F
    [J]. 2001 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL II, PROCEEDINGS, 2001, : 869 - 872
  • [14] Automatic tracking and boundary detection of the aorta in cardiac MR images using a deformable template model
    Watson, NA
    Lacey, A
    Carson, K
    Thacker, N
    Jackson, A
    [J]. RADIOLOGY, 1999, 213P : 364 - 365
  • [15] Cardiac Abnormalities Detection from Compressed ECG
    Torres-Cisneros, M.
    Guzman-Cabrera, R.
    Villalobos, S.
    May-Arrioja, D. A.
    Martell, F.
    [J]. COMPUTACION Y SISTEMAS, 2019, 23 (01): : 95 - 100
  • [16] Non-rigid motion estimation of ultrasound image sequences using an adaptive deformable mesh
    Yeung, F
    Levinson, SF
    Parker, KJ
    [J]. MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 : 806 - 817
  • [17] 4D reconstruction of cardiac gated SPECT images using a content-adaptive deformable mesh model
    Marin, Thibault
    Wernick, Miles N.
    Yang, Yongyi
    Brankov, Jovan G.
    [J]. MEDICAL IMAGING 2010: IMAGE PROCESSING, 2010, 7623
  • [18] Automatic Delineation of Left and Right Ventricles in Cardiac MRI Sequences Using a Joint Ventricular Model
    Lu, Xiaoguang
    Wang, Yang
    Georgescu, Bogdan
    Littman, Arne
    Comaniciu, Dorin
    [J]. FUNCTIONAL IMAGING AND MODELING OF THE HEART, 2011, 6666 : 250 - 258
  • [19] Left Ventricle Segmentation from Cardiac Cine MRI to Detect Cardiac Abnormalities
    Paul, R. Heldah
    Jeeva, J. B.
    [J]. 2014 INTERNATIONAL CONFERENCE ON COMMUNICATIONS AND SIGNAL PROCESSING (ICCSP), 2014,
  • [20] Detection of vehicle occlusion using a generalized deformable model
    Yung, NHC
    Lai, AHS
    [J]. ISCAS '98 - PROCEEDINGS OF THE 1998 INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-6, 1998, : C154 - C157