Biodistribution and Radiation Dosimetry of [18F]Mefway in Humans

被引:2
|
作者
Choi, Jae Yong [1 ]
Lyoo, Chul Hyoung [2 ]
Kim, Jin Su [3 ]
Kim, Kyeong Min [3 ]
Lee, Minkyung [4 ]
Ryu, Young Hoon [1 ]
机构
[1] Yonsei Univ, Gangnam Severance Hosp, Dept Nucl Med, Coll Med, Seoul, South Korea
[2] Yonsei Univ, Gangnam Severance Hosp, Dept Neurol, Coll Med, Seoul, South Korea
[3] Korea Inst Radiol & Med Sci, Mol Imaging Res Ctr, Seoul, South Korea
[4] Inha Univ Hosp, Dept Nucl Med, Inha Coll Med, Inchon, South Korea
基金
新加坡国家研究基金会;
关键词
5-HT1A receptor; PET; Dosimetry; F-18]Mefway; RECEPTOR-BINDING; PET; RADIOLIGAND; BRAIN;
D O I
10.1007/s11307-016-0955-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
[F-18]Mefway is a positron emission tomography (PET) radioligand for quantification of the brain serotonin 1A (5-HT1A) receptor density. The purpose of this study was to evaluate the radiation safety of [F-18]Mefway in humans. Six healthy volunteers (three males and three females) were whole-body PET scanned for 114 min after injection of [F-18]Mefway (226 +/- 35 MBq). Estimated radiation doses were determined by the OLINDA/EXM software. [F-18]Mefway was safe and well tolerated by all subjects. Residence time ranges from 0 (gallbladder) to 0.822 h (urinary bladder wall). While the estimated radiation doses in the reproductive and blood-forming organs were below 13.35-22.87 mu Sv/MBq, radiation dose in the urinary bladder wall was 471 mu Sv/MBq. The mean effective dose was 40.23 +/- 6.63 mu Sv/MBq. For a typical single injection of 185 MBq (5 mCi), the dose will result in 87.1 mSv for the urinary bladder wall. To reduce radiation burden, the bladder voiding can be used before [F-18]Mefway PET scan.
引用
收藏
页码:803 / 806
页数:4
相关论文
共 50 条
  • [31] Radiation dosimetry and biodistribution of [18F]PF-05270430, a radiotracer for phosphodiesterase 2A (PDE2A) in rhesus macaques and humans
    Constantinescu, Cristian
    Cole, Patricia
    Brown, Terry
    Morley, Thomas
    Papin, Caroline
    Alagille, David
    Jennings, Danna
    Russell, David
    Tamagnan, Gilles
    Seibyl, John
    Tauscher, Johannes
    Marek, Kenneth
    Barret, Olivier
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [32] Biodistribution and dosimetry studies of 18F FDG labeled leukocytes (18F FDG WBC) in human subjects.
    Forstrom, LA
    Dunn, WL
    Mullan, BP
    Hung, JC
    Lowe, VJ
    Thorson, LM
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 356P - 356P
  • [33] Radiation dosimetry of [18F]VAT in nonhuman primates
    Karimi, Morvarid
    Tu, Zhude
    Yue, Xuyi
    Zhang, Xiang
    Jin, Hongjun
    Perlmutter, Joel S.
    Laforest, Richard
    EJNMMI RESEARCH, 2015, 5 : 1 - 6
  • [34] Radiation dosimetry of [18F]PBR111
    Verschuer, Jordan
    Towson, Jocelyn
    Katsifis, Andrew
    Henderson, David
    Wen, Lingfeng
    Loc'h, Christian
    Eberl, Stefan
    Thomson, Sally
    Mohamed, Armin
    Fulham, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [35] Radiation dosimetry of [18F]VAT in nonhuman primates
    Morvarid Karimi
    Zhude Tu
    Xuyi Yue
    Xiang Zhang
    Hongjun Jin
    Joel S. Perlmutter
    Richard Laforest
    EJNMMI Research, 5
  • [36] Rodent study of [18F]-mefway using microPET
    Saigal, Neil
    Faheem, S.
    Coleman, R.
    Constantinescu, C.
    Mukherjee, J.
    NEUROIMAGE, 2008, 41 : T165 - T165
  • [37] Radiation Dosimetry of 18F-FPEB in Humans
    Kessler, Robert M.
    Seibyl, John
    Cowan, Ronald L.
    Zald, David
    Young, Jacob S.
    Ansari, Mohammad Sib
    Stabin, Michael G.
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (07) : 1119 - 1121
  • [38] Biodistribution and dosimetry of [18F]fluorodeoxyglucose labelled leukocytes in normal human subjects
    Forstrom, LA
    Dunn, WL
    Mullan, BP
    Hung, JC
    Lowe, VJ
    Thorson, LM
    NUCLEAR MEDICINE COMMUNICATIONS, 2002, 23 (08) : 721 - 725
  • [39] The clinical safety, biodistribution and internal radiation dosimetry of [18F]AH113804 in healthy adult volunteers
    E. J. Somer
    R. Owenius
    A. Wall
    G. Antoni
    A. Thibblin
    J. Sörensen
    EJNMMI Research, 6
  • [40] The clinical safety, biodistribution and internal radiation dosimetry of flutemetamol (18F) injection in healthy Japanese adult volunteers
    Senda, Michio
    Brooks, David J.
    Farrar, Gill
    Somer, Edward J.
    Paterson, Carolyn L.
    Sasaki, Masahiro
    McParland, Brian J.
    ANNALS OF NUCLEAR MEDICINE, 2015, 29 (07) : 627 - 635