Study on the response of indigenously developed CaSO4:Dy phosphor-based neutron dosemeter

被引:4
|
作者
Bakshi, A. K. [1 ]
Pradhan, A. S. [1 ]
Kher, R. K. [1 ]
Srivastava, K. [1 ]
Varadharajan, G. [1 ]
Chatterjee, S. [1 ]
Sathian, V. [2 ]
机构
[1] Bhabha Atom Res Ctr, Radiol Phys & Advisory Div, Mumbai 400085, Maharashtra, India
[2] Bhabha Atom Res Ctr, Radiat Safety Syst Div, Mumbai 400085, Maharashtra, India
关键词
MIXED FIELD DOSIMETRY; DY;
D O I
10.1093/rpd/ncp019
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the present paper, we report the indigenous development of a neutron-sensitive thermoluminescent dosemeter (TLD) based on CaSO4:Dy Teflon TL disc. The study includes indigenous development of a neutron dosemeter and its response in terms of operational quantity to different energies of neutrons under various irradiation conditions. It was found that the thermal neutron sensitivity of the CaSO4:Dy Teflon neutron disc is about one-third of TLD-600. However, the thermal neutron sensitivity with respect to CaSO4:Dy Teflon gamma disc is about 42 times for in-air irradiation and about 84 times for on-phantom irradiation condition. This newly developed neutron dosemeter can be used as a routine TLD with a slight change in the design of the TLD badge system in the mixed fields of gamma and neutrons of energy up to 500 keV for radiation workers engaged in nuclear fuel cycle operation and other applications.
引用
收藏
页码:73 / 80
页数:8
相关论文
共 50 条
  • [31] Further studies on the new high sensitive CaSO4:Dy thermostimulated luminescence phosphor
    Lakshmanan, AR
    Tomita, A
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 235 - 238
  • [32] Electron spin resonance evaluation of pure CaSO4 and as a phosphor doped with P and Dy
    de Jesus, EFO
    Rossi, AM
    Lopes, RT
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 553 - 556
  • [33] Estimation of Personal dose Equivalent Hp(0.07) Using CaSO4:Dy Teflon Disc-Based Extremity Dosemeter
    Bhattacharya, Madhumita
    Samuel, Kasthuri
    Patil, Sandeep
    Yadav, Rohit
    Bakshi, A. K.
    Singh, Sunil K.
    Sapra, B. K.
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (20) : 1546 - 1556
  • [34] Simulation of the energetic and angular response of a CaSO4:Dy dosemeter to weakly penetrating beta radiation using the EGS4 transport code
    Luguera, E
    Fernandez, F
    Domingo, C
    Baixeras, C
    Prevost, H
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 321 - 324
  • [35] Calculated energy dependence of CaSO4:Dy TL phosphor and phosphor embedded Teflon for X and gamma rays
    Chang, JK
    Nam, YM
    Kim, JL
    Chang, SY
    Kim, BH
    RADIATION MEASUREMENTS, 2001, 33 (05) : 675 - 678
  • [36] CASO4: DY response to radiation-therapy electron beams
    Nunes, M.
    Campos, L.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S133 - S134
  • [37] THERMO-LUMINESCENCE RESPONSE OF CASO4 - DY SINTERED PELLETS
    SHASTRY, SS
    SHINDE, SS
    BHATT, RC
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1980, 31 (04): : 244 - 245
  • [38] Measurement of gamma attenuation for ANR end shield model using CaSO4:Dy phosphor
    Bakshi, A. K.
    Suryanarayana, P.
    Sharma, Rajeev Kumar
    Maheshwari, N. K.
    Joshi, V. J.
    Chougaonkar, M. P.
    ANNALS OF NUCLEAR ENERGY, 2013, 55 : 205 - 210
  • [39] GLOW CURVE BEHAVIOR OF CASO4 - DY THERMOLUMINESCENT PHOSPHOR IN HIGH-DOSE REGION
    SRIVASTAVA, JK
    SUPE, SJ
    NUCLEAR INSTRUMENTS & METHODS, 1979, 160 (03): : 529 - 532
  • [40] AN IMPROVED CASO4(DY)-6LI2SO4 MIXED THERMOLUMINESCENT PHOSPHOR IN TEFLON FOR ENHANCED NEUTRON DOSE DISCRIMINATION
    CHABOT, GE
    THORNHILL, M
    COUILLARD, J
    SKRABLE, KW
    DISTENFELD, C
    HEALTH PHYSICS, 1982, 43 (01): : 130 - 130