Digital mammography screening: how many breast cancers are additionally detected by bilateral ultrasound examination during assessment?

被引:17
|
作者
Weigel, Stefanie [1 ,2 ]
Biesheuvel, Cornelis [1 ,2 ]
Berkemeyer, Shoma [1 ,2 ]
Kugel, Harald [1 ,2 ]
Heindel, Walter [1 ,2 ]
机构
[1] Univ Hosp Muenster, Dept Clin Radiol, D-48149 Munster, Germany
[2] Univ Hosp Muenster, Reference Ctr Mammog, D-48149 Munster, Germany
关键词
Breast cancer; Digital mammography screening; Breast ultrasound; Early detection of cancer; Predictive value of tests; PATHOLOGICAL FEATURES; INTERVAL CANCER; WOMEN; DENSITY; US; PERFORMANCE; SONOGRAPHY; RISK;
D O I
10.1007/s00330-012-2664-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the positive predictive values of incremental breast cancer detection (PPV1) in relation to the mammographic breast density and of performed biopsies (PPV3) resulting from supplemental bilateral physician-performed whole-breast ultrasound (US) at recall of a population-based digital mammography screening programme. A total of 2,803 recalled screening participants (50-69 years), who had additional bilateral US with prospectively completed documentation [grading of breast density (ACR 1-4), biopsy recommendation related to US and mammography], were included. The PPV1 of supplemental cancer detection only by US was 0.21 % (6/2,803) compared to 13.8 % (386/2,803) by mammography. The PPV1 of US-only cancer detection was 0 %, 0.16 % (2/1,220), 0.22 % (3/1,374) and 1.06 % (1/94) for women with breast density of ACR 1, ACR 2, ACR 3 and ACR 4, respectively. The PPV3 of US-only lesion detection was 33.3 % (9/27) compared to 38.0 % (405/1,066) by mammography. The proportion of invasive cancers no larger than 10 mm was 37.5 % (3/8) for US-only detection compared to 38.4 % (113/294) for mammographic detection. Bilateral ultrasound at recall, in addition to the assessment of screen-detected mammographic abnormalities, resulted in a low PPV of incremental cancer detection only by US, without a disproportional increase of false-positive biopsies.
引用
收藏
页码:684 / 691
页数:8
相关论文
共 50 条
  • [1] Digital mammography screening: how many breast cancers are additionally detected by bilateral ultrasound examination during assessment?
    Stefanie Weigel
    Cornelis Biesheuvel
    Shoma Berkemeyer
    Harald Kugel
    Walter Heindel
    European Radiology, 2013, 23 : 684 - 691
  • [2] Comparison of breast cancers detected in the Verona screening program following transition to digital breast tomosynthesis screening with cancers detected at digital mammography screening
    Francesca Caumo
    Giovanna Romanucci
    Kylie Hunter
    Manuel Zorzi
    Silvia Brunelli
    Petra Macaskill
    Nehmat Houssami
    Breast Cancer Research and Treatment, 2018, 170 : 391 - 397
  • [3] Comparison of breast cancers detected in the Verona screening program following transition to digital breast tomosynthesis screening with cancers detected at digital mammography screening
    Caumo, Francesca
    Romanucci, Giovanna
    Hunter, Kylie
    Zorzi, Manuel
    Brunelli, Silvia
    Macaskill, Petra
    Houssami, Nehmat
    BREAST CANCER RESEARCH AND TREATMENT, 2018, 170 (02) : 391 - 397
  • [4] Digital Mammography Screening - Evidence of Incremental Breast Cancer Detection by Bilateral Ultrasound at Assessment
    Biesheuvel, C.
    Heindel, W.
    Weigel, S.
    EUROPEAN JOURNAL OF CANCER, 2012, 48 : S72 - S72
  • [5] Comparison of Cancers Detected by Screening Breast Ultrasound and Digital Breast Tomosynthesis
    Destounis, Stamatia
    Arieno, Andrea
    Santacroce, Amanda
    ACADEMIC RADIOLOGY, 2022, 29 (03) : 339 - 347
  • [6] Frequency and characteristics of additionally detected ipsilateral breast lesions following recall at screening mammography
    Lameijer, Joost R. C.
    Coolen, Angela M. P.
    Nederend, Joost
    Voogd, Adri C.
    Tjan-Heijnen, Vivianne C. G.
    Duijm, Lucien E. M.
    BREAST, 2018, 42 : 94 - 101
  • [7] Molecular subtypes of breast cancers detected in mammography screening and outside of screening
    Sihto, Hard
    Lundin, Johan
    Lehtimaki, Tina
    Sarlomo-Rikala, Maarit
    Butzow, Ralf
    Holli, Kaija
    Sailas, Liisa
    Kataja, Vesa
    Lundin, Mikael
    Turpeenniemi-Hujanen, Thina
    Isola, Jorma
    Heikkila, Paivi
    Joensuu, Heikki
    CLINICAL CANCER RESEARCH, 2008, 14 (13) : 4103 - 4110
  • [8] Artificial Intelligence Improves Detection of Supplemental Screening Ultrasound-detected Breast Cancers in Mammography
    Yoen, Heera
    Chang, Jung Min
    JOURNAL OF BREAST CANCER, 2023, 26 (05) : 504 - 513
  • [9] Microcalcifications Detected at Screening Mammography: Synthetic Mammography and Digital Breast Tomosynthesis versus Digital Mammography
    Lai, Yi-Chen
    Ray, Kimberly M.
    Lee, Amie Y.
    Hayward, Jessica H.
    Freimanis, Rita I.
    Lobach, Iryna V.
    Joe, Bonnie N.
    RADIOLOGY, 2018, 289 (03) : 630 - 638
  • [10] The Natural History of Invasive Breast Cancers Detected by Screening Mammography
    Zahl, Per-Henrik
    Maehlen, Jan
    Welch, Gilbert
    ARCHIVES OF INTERNAL MEDICINE, 2008, 168 (21) : 2311 - 2316