Simultaneous Determination of Catechol and Hydroquinone using N, P co-doped Carbon Derived from Ionic Liquid

被引:8
|
作者
Ma, Yan [1 ,2 ]
Cao, Zhanping [1 ,2 ]
Wang, Ye [1 ,2 ]
Xia, Yingli [1 ,2 ]
He, Chongchong [1 ,2 ]
Wang, Leilei [1 ,2 ]
Bao, Saisai [1 ,2 ]
Yin, Pingmei [1 ,2 ]
Wang, Lili [1 ,2 ]
Gao, Jian [1 ,2 ]
Wang, Hong [1 ,3 ]
Yin, Zhen [1 ,2 ]
机构
[1] Tianjin Polytech Univ, State Key Lab Separat Membranes & Membrane Proc, Tianjin 300387, Peoples R China
[2] Tianjin Polytech Univ, Sch Environm & Chem Engn, Tianjin 300387, Peoples R China
[3] Tianjin Polytech Univ, Sch Mat Sci & Engn, Tianjin 300387, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Ionic liquids; N; P co-doped carbon; Hydroquinone; Catechol; Simultaneous determination; GRAPHENE OXIDE; ELECTROCHEMICAL SENSOR; ELECTROCATALYTIC ACTIVITY; DIHYDROXYBENZENE ISOMERS; MODIFIED ELECTRODE; HIGH-PERFORMANCE; FACILE SYNTHESIS; COMPOSITE FILM; REDUCTION; NANOCOMPOSITE;
D O I
10.20964/2019.04.64
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The N, P co-doped carbon (N-P-C) was prepared with the ionic liquid (IL) of hydrated pyridium dihydrate phosphate ([Hpdy]DHP). As precursors via one-pot pyrolysis. The N-P-C was used to modify the glassy carbon electrode (GCE) for simultaneous determination of hydroquinone (HQ) and catechol (CC). The obtained N-P-C was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), Raman spectroscopy and electrochemical techniques. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques were employed to investigate the catalytic performance of simultaneous determination of HQ and CC. The N-P-C/GCE exhibits wide linear responses (from 5 to 400 mu M), low detection limit (0.98 mu M for HQ and 0.61 mu M for CC, ratio of signal-to-noise 3) and superior sensitivity of 1.1 AM(-1) cm(-2) for HQ and 1.4 AM(-1) cm(-2) for CC in the simultaneous detection of HQ and CC, demonstrating superior detection performance even compared with the state-of-art carbon materials, such as N-doped graphene, graphene oxide or carbon nanotubes. Moreover, it displayed the favorable reproducibility and good longterm stability.
引用
收藏
页码:3916 / 3931
页数:16
相关论文
共 50 条
  • [21] Carbon aerogels with nickel@N-doped carbon core-shell nanoclusters as electrochemical sensors for simultaneous determination of hydroquinone and catechol
    Chen, Yang
    He, Ting
    Liao, Dan
    Li, Qiang
    Song, Yaya
    Xue, Hui
    Zhang, Yi
    ELECTROCHIMICA ACTA, 2022, 414
  • [22] Simultaneous Determination of Hydroquinone and Catechol by N-doped Porous Biochar-modified Electrode
    Liu, Yue-Xin
    Du, Shi-Man
    Cao, Jie
    Huang, Wen-sheng
    Zhang, Xiao-Ru
    Qi, Bao-Ping
    Zhang, Sheng-Hui
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2020, 41 (03) : 261 - 265
  • [23] Simultaneous determination of hydroquinone and catechol Using poly(p-aminobenzoic acid) modified glassy carbon electrode
    Yang, Ping
    Zhu, Qiyong
    Chen, Yonghong
    Wang, Fengwu
    Journal of Applied Polymer Science, 2009, 113 (05): : 2881 - 2886
  • [24] Simultaneous Determination of Hydroquinone and Catechol Using Poly(p-aminobenzoic acid) Modified Glassy Carbon Electrode
    Yang, Ping
    Zhu, Qiyong
    Chen, Yonghong
    Wang, Fengwu
    JOURNAL OF APPLIED POLYMER SCIENCE, 2009, 113 (05) : 2881 - 2886
  • [25] A sensor based on graphitic mesoporous carbon/ionic liquids composite film for simultaneous determination of hydroquinone and catechol
    Hong, Zhouqin
    Zhou, Lihui
    Li, Jinxia
    Tang, Jing
    ELECTROCHIMICA ACTA, 2013, 109 : 671 - 677
  • [26] A novel electrochemical sensor based on a hybrid composed of CoZn/ N-doped porous carbon for the simultaneous determination of catechol and hydroquinone
    Zhou, Qirong
    Wu, Feng
    Zou, Qiongyu
    Zhang, Yin
    Xie, Yixi
    Ouyang, Yuejun
    Fei, Junjie
    Zhang, Li
    MICROCHEMICAL JOURNAL, 2025, 212
  • [27] A sensor based on Mo, N, S-doped interconnected porous carbon spheres material for simultaneous determination of hydroquinone and catechol
    Jiao, Shoufeng
    Tang, Junhua
    Li, Xiang
    Zhai, Yadong
    Li, Maoguo
    MICROCHEMICAL JOURNAL, 2025, 211
  • [28] Facile Simultaneous Determination of Hydroquinone and Catechol Using Nitrogen-doped Graphene Modified Electrode
    Lu, Zan
    Li, Dongning
    Zhang, Qianli
    Wei, Jie
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (12): : 10607 - 10619
  • [29] In-situ N, P co-doped porous carbon derived from biomass waste for supercapacitors
    Yang, Xuan
    Wang, Xueqin
    Yu, Xuewen
    Ye, Xuan
    Lu, Beili
    Huang, Biao
    Lin, Guanfeng
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2024, 972
  • [30] Simultaneous determination of hydroquinone and catechol using a modified glassy carbon electrode by ruthenium red/carbon nanotube
    Mohammad Mehdi Foroughi
    Meissam Noroozifar
    Mozhgan Khorasani-Motlagh
    Journal of the Iranian Chemical Society, 2015, 12 : 1139 - 1147