Improved Fat Suppression Using Multipeak Reconstruction for IDEAL Chemical Shift Fat-Water Separation: Application with Fast Spin Echo Imaging

被引:26
|
作者
Kijowski, Richard [1 ]
Woods, Michael A. [1 ]
Lee, Kenneth S. [1 ]
Takimi, Kuya [1 ]
Yu, Huanzhou [5 ]
Shimakawa, Ann [5 ]
Brittain, Jean H. [6 ]
Reeder, Scott B. [1 ,2 ,3 ,4 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Biomed Engn, Madison, WI 53706 USA
[4] Univ Wisconsin, Dept Med, Madison, WI 53706 USA
[5] GE Healthcare, MR Global Appl Sci Lab, Menlo Pk, CA USA
[6] GE Healthcare, MR Global Appl Sci Lab, Madison, WI USA
关键词
IDEAL; fat-water separation; fat suppression; MRI; knee; DIXON TECHNIQUE; DECOMPOSITION; EXCITATION; PROTON; PITFALLS; STIR;
D O I
10.1002/jmri.21664
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate and quantify improvements in the quality of fat suppression for fast spin-echo imaging of the knee using multipeak fat spectral modeling and IDEAL fat-water separation. Materials and Methods: T(1)-weighted and T(2)-weighted fast spin-echo sequences with IDEAL fat-water separation and two frequency-selective fat-saturation methods (fat-selective saturation and fat-selective partial inversion) were performed on 10 knees of five asymptomatic volunteers. The IDEAL images were reconstructed using a conventional single-peak method and precalibrated and self-calibrated multipeak methods that more accurately model the NMR spectrum of fat. The signal-to-noise ratio (SNR) was measured in various tissues for all sequences. Student t-tests were used to compare SNR values. Results: Precalibrated and self-calibrated multipeak IDEAL had significantly greater suppression of signal (P < 0.05) within subcutaneous fat and bone marrow than fat-selective saturation, fat-selective partial inversion, and single-peak IDEAL for both T(1)-weighted and T(2)-weighted fast spin-echo sequences. For T(1)-weighted fast spin-echo sequences, the improvement in the suppression of signal within subcutaneous fat and bone marrow for multipeak IDEAL ranged between 65% when compared to fat-selective partial inversion to 86% when compared to fat-selective-saturation. For T(2)-weighted fast spin-echo sequences, the improvement for multipeak IDEAL ranged between 21% when compared to fat-selective partial inversion to 81% when compared to fat-selective saturation. Conclusion: Multipeak IDEAL fat-water separation provides Improved fat suppression for T(1)-weighted and T(2)-weighted fast spin-echo imaging of the knee when compared to single-peak IDEAL and two widely used frequency-selected fat-saturation methods.
引用
收藏
页码:436 / 442
页数:7
相关论文
共 50 条
  • [31] Deep Learning-Based Water-Fat Separation from Dual-Echo Chemical Shift-Encoded Imaging
    Wu, Yan
    Alley, Marcus
    Li, Zhitao
    Datta, Keshav
    Wen, Zhifei
    Sandino, Christopher
    Syed, Ali
    Ren, Hongyi
    Xing, Lei
    Lustig, Michael
    Pauly, John
    Vasanawala, Shreyas
    BIOENGINEERING-BASEL, 2022, 9 (10):
  • [32] T2-Weighted 3D Fast Spin Echo Imaging With Water-Fat Separation in a Single Acquisition
    Madhuranthakam, Ananth J.
    Yu, Huanzhou
    Shimakawa, Ann
    Busse, Reed F.
    Smith, Martin P.
    Reeder, Scott B.
    Rofsky, Neil M.
    Brittain, Jean H.
    McKenzie, Charles A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (03) : 745 - 751
  • [33] FAST SPIN-ECHO IMAGING OF THE NECK - COMPARISON WITH CONVENTIONAL SPIN-ECHO, UTILITY OF FAT-SUPPRESSION, AND EVALUATION OF TISSUE CONTRAST CHARACTERISTICS
    LEWIN, JS
    CURTIN, HD
    ROSS, JS
    WEISSMAN, JL
    OBUCHOWSKI, NA
    TKACH, JA
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (07) : 1351 - 1357
  • [34] Noninvasive Temperature Mapping With MRI Using Chemical Shift Water-Fat Separation
    Soher, Brian J.
    Wyatt, Cory
    Reeder, Scott B.
    MacFall, James R.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (05) : 1238 - 1246
  • [35] FAT AND WATER SEPARATION AT 0.23-T USING SIMULTANEOUS SHIFT SELECTIVE IMAGING
    HENNIG, J
    FRIEDBURG, H
    MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) : 844 - 848
  • [37] Grading the articular cartilage of the knee using standard fast spin-echo sequences without fat suppression
    Sonin, AH
    Pensy, RA
    Mulligan, ME
    Hatem, SF
    RADIOLOGY, 1999, 213P : 373 - 374
  • [38] Phase sensitive reconstruction for Water/Fat separation in MR Imaging using inverse gradient
    Rydell, Joakim
    Knutsson, Hans
    Pettersson, Johanna
    Johansson, Andreas
    Farneback, Gunnar
    Dahlqvist, Olof
    Lundberg, Peter
    Nystrom, Fredrik
    Borga, Magnus
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2007, PT 1, PROCEEDINGS, 2007, 4791 : 210 - +
  • [39] Improved fat-suppression homogeneity with mDIXON turbo spin echo (TSE) in pediatric spine imaging at 3.0 T
    Pokorney, Amber L.
    Chia, Jonathan M.
    Pfeifer, Cory M.
    Miller, Jeffrey H.
    Hu, Houchun H.
    ACTA RADIOLOGICA, 2017, 58 (11) : 1386 - 1394
  • [40] IMAGING OF THE HYALINE HIP-JOINT CARTILAGE USING MR TOMOGRAPHY WITH GRADIENT ECHO SEQUENCE WITH FAT-WATER PHASE COHERENCE
    WRAZIDLO, W
    SCHNEIDER, S
    RICHTER, GM
    KAUFFMANN, GW
    BLASIUS, K
    GOTTSCHLICH, KW
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1990, 152 (01): : 56 - 59