Improved Fat Suppression Using Multipeak Reconstruction for IDEAL Chemical Shift Fat-Water Separation: Application with Fast Spin Echo Imaging
被引:26
|作者:
Kijowski, Richard
[1
]
Woods, Michael A.
[1
]
Lee, Kenneth S.
[1
]
Takimi, Kuya
[1
]
Yu, Huanzhou
[5
]
Shimakawa, Ann
[5
]
Brittain, Jean H.
[6
]
Reeder, Scott B.
[1
,2
,3
,4
]
机构:
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Biomed Engn, Madison, WI 53706 USA
[4] Univ Wisconsin, Dept Med, Madison, WI 53706 USA
[5] GE Healthcare, MR Global Appl Sci Lab, Menlo Pk, CA USA
[6] GE Healthcare, MR Global Appl Sci Lab, Madison, WI USA
关键词:
IDEAL;
fat-water separation;
fat suppression;
MRI;
knee;
DIXON TECHNIQUE;
DECOMPOSITION;
EXCITATION;
PROTON;
PITFALLS;
STIR;
D O I:
10.1002/jmri.21664
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: To evaluate and quantify improvements in the quality of fat suppression for fast spin-echo imaging of the knee using multipeak fat spectral modeling and IDEAL fat-water separation. Materials and Methods: T(1)-weighted and T(2)-weighted fast spin-echo sequences with IDEAL fat-water separation and two frequency-selective fat-saturation methods (fat-selective saturation and fat-selective partial inversion) were performed on 10 knees of five asymptomatic volunteers. The IDEAL images were reconstructed using a conventional single-peak method and precalibrated and self-calibrated multipeak methods that more accurately model the NMR spectrum of fat. The signal-to-noise ratio (SNR) was measured in various tissues for all sequences. Student t-tests were used to compare SNR values. Results: Precalibrated and self-calibrated multipeak IDEAL had significantly greater suppression of signal (P < 0.05) within subcutaneous fat and bone marrow than fat-selective saturation, fat-selective partial inversion, and single-peak IDEAL for both T(1)-weighted and T(2)-weighted fast spin-echo sequences. For T(1)-weighted fast spin-echo sequences, the improvement in the suppression of signal within subcutaneous fat and bone marrow for multipeak IDEAL ranged between 65% when compared to fat-selective partial inversion to 86% when compared to fat-selective-saturation. For T(2)-weighted fast spin-echo sequences, the improvement for multipeak IDEAL ranged between 21% when compared to fat-selective partial inversion to 81% when compared to fat-selective saturation. Conclusion: Multipeak IDEAL fat-water separation provides Improved fat suppression for T(1)-weighted and T(2)-weighted fast spin-echo imaging of the knee when compared to single-peak IDEAL and two widely used frequency-selected fat-saturation methods.
引用
收藏
页码:436 / 442
页数:7