Grid-connected photovoltaic inverters with low-voltage ride through for a residential-scale system: A review

被引:14
|
作者
Talha, Muhammad [1 ]
Amir, Asim [1 ,2 ]
Raihan, Siti Rohani Sheikh [1 ]
Abd Rahim, Nasrudin [1 ]
机构
[1] Univ Malaya, UM Power Energy Dedicated Adv Ctr UMPEDAC, Wisma R&D, Level 4, Kuala Lumpur 59990, Malaysia
[2] IIT, Dept Elect & Comp Engn, Chicago, IL 60616 USA
关键词
grid-tied PV system; grid stability; inverter design; low voltage ride through (LVRT); roof-top PV; MODEL-PREDICTIVE CONTROL; SINGLE-PHASE; HARMONIC ESTIMATION; CONTROL STRATEGIES; STABILITY ANALYSIS; LVRT CAPABILITY; POWER-CONTROL; PV INVERTER; DESIGN; SYNCHRONIZATION;
D O I
10.1002/2050-7038.12630
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Background Recent advancements in solar power generation technology have paved the way for a vast number of photovoltaic (PV) systems integration into the grid network. The global installed capacity of rooftop PV systems has already surpassed a 50 GW mark in 2020, while the total installed capacity of all types of PV systems is reaching beyond 500 GW. The influx of distributed PV-generators must be equipped with sophisticated control to ensure grid stability, especially during grid faults. A devastating grid outage may occur if the grid-tied PV inverters are not equipped with the "fault-ride-through" mechanism. Many countries have already enforced a mandatory grid code which includes a low-voltage-ride through requirements for PV-generators. Aim and Objective This paper reviews the design of a rooftop PV inverters in the light of low-voltage-ride-through requirements. Materials and Methods For the implementation of low-voltage-ride-through (LVRT), the design of low-voltage-sag detection, grid-synchronization, filter-selection, and power-controllers are examined through simulations and literature survey. LVRT implementation issues are highlighted with an emphasis on the current controller performance during grid sags. Results and Discussion From the review and analysis conducted in this study, this paper concludes that ensuring a stable DC-link and appropriate control-reference-signals during the grid faults are the keys to the LVRT implementation. Conclusion In addition to robust power control, an autonomous PV generator should promptly detect the grid conditions and fulfils the ancillary services like LVRT, anti-islanding and flicker compensation. The recommendations and the future trends in the LVRT research conclude the review article.
引用
收藏
页数:28
相关论文
共 50 条
  • [21] Faults and Fault Ride Through strategies for grid-connected photovoltaic system: A comprehensive review
    Zeb, Kamran
    Ul Islam, Saif
    Khan, Imran
    Uddin, Waqar
    Ishfaq, M.
    Busarello, Tiago Davi Curi
    Muyeen, S. M.
    Ahmad, Iftikhar
    Kim, H. J.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2022, 158
  • [22] Voltage Sag Detection in Grid-connected Photovoltaic Power Plant for Low Voltage Ride-through Control
    Al-Shetwi, Ali Qasem
    Sujod, Muhamad Zahim
    RECENT ADVANCES IN ELECTRICAL & ELECTRONIC ENGINEERING, 2019, 12 (04) : 384 - 392
  • [23] Control Strategy of Low Voltage Ride-Through for Grid-Connected Photovoltaic Power System Based on Predictive Current
    Zhang, Mingguang
    Chen, Xiaojing
    MECHATRONICS ENGINEERING, COMPUTING AND INFORMATION TECHNOLOGY, 2014, 556-562 : 1753 - 1756
  • [24] Grid connected converters with enhanced low-voltage ride through capability
    Kaur, Gurpreet
    Moulik, Bedatri
    Rao, K. Uma
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2023, 48 (04):
  • [25] Grid connected converters with enhanced low-voltage ride through capability
    Gurpreet Kaur
    Bedatri Moulik
    K Uma Rao
    Sādhanā, 48
  • [26] A Novel Low Voltage Ride Through Strategy of Two-Stage Grid-Connected Photovoltaic Inverter
    Wang, Shuzheng
    Yao, Xiaojun
    Zhao, Jianfeng
    2013 1ST INTERNATIONAL FUTURE ENERGY ELECTRONICS CONFERENCE (IFEEC 2013), 2013, : 400 - 405
  • [27] Low Voltage Ride Through Control Strategy for High-Power Grid-Connected Photovoltaic Inverter
    Bao, Xianwen
    Tan, Peixuan
    Zhuo, Fang
    Yue, Xiaolong
    2013 TWENTY-EIGHTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2013), 2013, : 97 - 100
  • [28] An Inrush Current Mitigation Method for the Grid-Connected Converters in the Low-Voltage Ride-Through Operation
    Chen, Hsin-Chih
    Ko, Hsin-Cheng
    Cheng, Po-Tai
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 1717 - 1724
  • [29] A Low-Voltage Ride-Through Technique for Grid-Connected Converters With Reduced Power Transistors Stress
    Chen, Hsin-Chih
    Lee, Chia-Tse
    Cheng, Po-Tai
    Teodorescu, Remus
    Blaabjerg, Frede
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (12) : 8562 - 8571
  • [30] Evaluation of Low-Voltage Ride-Through Capability of a Two-Stage Grid-Connected Three-Level Photovoltaic Inverter
    Wang, Yuewu
    Yang, Ping
    Yin, Xu
    Ma, Yiwei
    2014 17TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2014, : 822 - 828