Over-the-needle versus microcatheter-through-needle technique for continuous spinal anesthesia: A preliminary study

被引:0
|
作者
Muralidhar, V [1 ]
Kaul, HL [1 ]
Mallick, P [1 ]
机构
[1] All India Inst Med Sci, Dept Anesthesiol, New Delhi 110029, India
关键词
continuous spinal anesthesia; technique; postoperative pain;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Objectives. A new catheter-over-needle design (Spinocath, B. Braun) has been developed to minimize problems and complications of continuous spinal anesthesia with microcatheters, which include difficult catheter insertion, failure of insertion, breakage, inadequate anesthesia, postdural puncture headache, and, rarely, development of cauda equina syndrome. Methods. A comparative evaluation of this new catheter (22-gauge Spinocath) to the microcatheter (28-gauge Porter) was performed to study the problems of insertion, complications, quality of anesthesia, and postoperative analgesia in a prospective, randomized manner. Patients were allocated to two groups of 10 each: catheter-over-the-needle group (group I) and microcatheter-through-the needle (group II). Postoperative protocol consisted of an infusion of 0.125% isobaric bupivacaine delivered with a syringe infusion pump, fnr 24 hours. Results. The two groups were comparable in relation to age, sex, type of surgery, median height of the block, and the lime taken for catheter insertion and surgery. Spontaneous backflow of cerebrospinal fluid (CSF) through the catheter with the needle in position was possible only in the spinocath group (8/10 cases). Initial introduction of the catheter into the subarachnoid space (8 vs 3: chi-square = 5.05; P = .03) and threading of the catheter were easier (8 vs 3 cases: chi-square = 5.05; P = .03) in group I. Aspiration of CSF was easy in,group I in all (10 vs 2: chi-square = 13.33; P = .004). Complications such as resistance to drug injection, kinking (P < .05), inadequate anesthesia, and supplementation with general anesthesia were seen only in group II. Postoperative pain relief was comparable in both groups (P > .05). Both groups were comparable hemodynamically in the intra- and postoperative periods. Conclusions. Insertion, maintenance, and clinical effects were better achieved with the catheter-over-the needle design compared to the microcatheter. These preliminary findings need to be confirmed by a larger study.
引用
收藏
页码:417 / 421
页数:5
相关论文
共 50 条
  • [21] No additional metal particle formation using the needle-through-needle combined epidural spinal technique
    Herman, N
    Molin, J
    Knape, KG
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1996, 40 (02) : 227 - 231
  • [22] A clinical comparison between needle-through-needle and double-segment techniques for combined spinal and epidural anesthesia
    Casati, A
    D'Ambrosio, A
    De Negri, P
    Panelli, G
    Tagariello, V
    Tarantino, F
    [J]. REGIONAL ANESTHESIA AND PAIN MEDICINE, 1998, 23 (04): : 390 - 394
  • [23] Failed dural puncture during needle-through-needle combined spinal-epidural anesthesia: a case series
    Doo, A. Ram
    Shin, Yu Seob
    Choi, Jin-wook
    Yoo, Seonwoo
    Kang, Sehrin
    Son, Ji-seon
    [J]. JOURNAL OF PAIN RESEARCH, 2019, 12 : 1615 - 1619
  • [24] A REEVALUATION OF THE WHITACRE SPINAL NEEDLE IN OBSTETRIC ANESTHESIA - A PILOT-STUDY
    THOMAS, TA
    NOBLE, HA
    [J]. ANAESTHESIA, 1990, 45 (06) : 489 - 489
  • [25] A simulated model investigation of dry tap associated with needle-through-needle technique in combined spinal epidurals
    Tran, Cody
    Kim, Kristina
    Cordovani, Daniel
    [J]. CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2022, 69 (09): : 1182 - 1184
  • [26] A simulated model investigation of dry tap associated with needle-through-needle technique in combined spinal epidurals
    Cody Tran
    Kristina Kim
    Daniel Cordovani
    [J]. Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2022, 69 : 1182 - 1184
  • [27] The Wiley Spinal Catheter-Over-Needle System for Continuous Spinal Anesthesia A Case Series of 5 Cesarean Deliveries Complicated by Paresthesias and Headaches
    McKenzie, Christine P.
    Carvalho, Brendan
    Riley, Edward T.
    [J]. REGIONAL ANESTHESIA AND PAIN MEDICINE, 2016, 41 (03) : 405 - 410
  • [28] COMBINED SPINAL EPIDURAL-ANESTHESIA FOR CESAREAN-SECTION USING THE NEEDLE THROUGH NEEDLE TECHNIQUE - EFFECTS OF SUBCUTANEOUS OF EPIDURAL BUPRENORPHINE (BU) FOR PROLONGATION OF POSTOPERATIVE ANALGESIA
    WYSS, E
    MONS, P
    TEISSIER, JM
    GUILLAUME, JL
    PIERROT, B
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 : 103 - 103
  • [29] Paraesthesiae during needle-through-needle combined spinal epidural versus single-shot spinal for elective caesarean section
    McAndrew, CR
    Harms, P
    [J]. ANAESTHESIA AND INTENSIVE CARE, 2003, 31 (05) : 514 - 517
  • [30] Optimal angle of needle insertion for spinal anesthesia in patients with spondylolisthesis: an ultrasonographic study
    Youngwon Kim
    Seokha Yoo
    Sun-Kyung Park
    Hansu Bae
    Young-Jin Lim
    Jin-Tae Kim
    [J]. BMC Anesthesiology, 21