Multiple fault diagnosis on a synchronous 2 pole generator using shaft and flux probe signals

被引:0
|
作者
Doorsamy, Wesley [1 ]
Cronje, Willie A. [1 ]
Meyer, Alan S. [1 ]
机构
[1] Univ Witwatersrand, Sch Elect & Informat Engn, Johannesburg, South Africa
来源
2013 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT) | 2013年
关键词
fault diagnosis; shaft signals; synchronous generator; finite element analysis;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A method for diagnosis of multiple incipient faults on a 2-pole synchronous generator is presented. Simulation of the generator on a finite element analysis (FEA) software package is used to predict the effects of these faults. Experimental analysis of the generator under fault conditions is then conducted and confirms the predicted behaviour. The investigation utilises shaft brushes as a non-invasive condition monitoring tool and search coils are used to validate findings from the shaft signal analysis. Results of the investigation indicate definitive relationships between the faults and specific harmonics of the output signals from the condition monitoring tools.
引用
收藏
页码:362 / 367
页数:6
相关论文
共 50 条
  • [21] Fisher vector encoding for improving the performance of fault diagnosis in a synchronous generator
    Gopinath, R.
    Kumar, C. Santhosh
    Ramachandran, K. I.
    MEASUREMENT, 2017, 111 : 264 - 270
  • [22] Signal-Model-Based Fault Diagnosis in Windings of Synchronous Generator
    Masoumi, Zahra
    Moaveni, Bijan
    Gazafrudi, Sayed Mohammad Mousavi
    Faiz, Jawad
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2023, 19 (03) : 2942 - 2951
  • [23] Diagnosis of excessive vibration signals of two-pole generator rotors in balancing
    Jong-Po Park
    KSME International Journal, 2000, 14 : 590 - 596
  • [24] Diagnosis of excessive vibration signals of two-pole generator rotors in balancing
    Park, JP
    KSME INTERNATIONAL JOURNAL, 2000, 14 (06): : 590 - 596
  • [25] Analytic Method for Eccentricity Fault Diagnosis in Salient-pole Synchronous Generators
    Sadeghi, Iman
    Ehya, Hossein
    Faiz, Jawad
    2017 INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT (OPTIM) & 2017 INTL AEGEAN CONFERENCE ON ELECTRICAL MACHINES AND POWER ELECTRONICS (ACEMP), 2017, : 261 - 267
  • [26] SHAFT SIGNALS OF SALIENT-POLE SYNCHRONOUS MACHINES FOR ECCENTRICITY AND SHORTED-FIELD-COIL DETECTIONS
    HSU, JS
    STEIN, J
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 1994, 9 (03) : 572 - 578
  • [27] Calculation of Unbalanced Magnetic Pull in a Salient-Pole Synchronous Generator Using Finite-Element Method and Measured Shaft Orbit
    Zarko, Damir
    Ban, Drago
    Vazdar, Ivan
    Jaric, Vladimir
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (06) : 2536 - 2549
  • [28] Suppressing effect of fault current limiter on shaft torsional torque of synchronous generator in consumer system
    Iioka, D
    Shimizu, H
    Yokomizu, Y
    Goto, M
    Matsumura, T
    Kano, I
    IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 2373 - 2377
  • [29] A Detailed Analytical Model of a Salient-Pole Synchronous Generator Under Dynamic Eccentricity Fault
    Babaei, Mojtaba
    Faiz, Jawad
    Ebrahimi, Bashir Mahdi
    Amini, S.
    Nazarzadeh, Jalal
    IEEE TRANSACTIONS ON MAGNETICS, 2011, 47 (04) : 764 - 771
  • [30] Diagnosis of brushless synchronous generator using numerical modeling
    Rahnama, Mehdi
    Vahedi, Abolfazl
    Mohammad-Alikhani, Arta
    Takorabet, Noureddine
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2020, 39 (05) : 1241 - 1254