Numerical Study of Boiler Feed Water Deoxygenation using Hollow Fiber Membrane Contactor

被引:0
|
作者
Zhang, Xiaoguang [1 ,2 ]
Wang, Shigang [1 ]
机构
[1] Qingdao Univ Sci & Technol, Coll Electromech Engn, 99 Songling Rd, Qingdao 266061, Peoples R China
[2] Qingdao Univ Sci & Technol, Shandong Provincial Key Lab Polymer Mat Adv Manuf, Qingdao 266061, Peoples R China
来源
关键词
mass transfer coefficient; dissolved oxygen; gauss distribution; packing density; hollow fiber membrane contactor; MASS-TRANSFER; MODULES; PERFORMANCE; FLOW;
D O I
10.4028/www.scientific.net/KEM.561.206
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Removal of dissolved oxygen from feed water is a necessary process in power industry. The hollow fiber membrane contactor is more efficient and pollution-free compared with some traditional methods. In this paper, hollow fiber is modeled by random distribution, and Gaussian function N(R, sigma) was used to model the polydisperse out radii of hollow fiber. This paper discussed the influence of different sigma on mass transfer coefficient with fiber packing density ranging from 0.1 to 0.4. It was found that, the effect of different sigma on the logarithmic mean Sherwood number decreased with increasing fiber packing density. When the packing density increased to 0.4, the removal of dissolved oxygen could meet the requirement of power industry, no matter how much value the sigma was. With the sigma increasing, the deviation of max and min Sherwood number from the average value increased gradually, except when the sigma was 0.05. This paper deduces there is a best value of sigma for membrane contactor when the fiber distribution is randomly distributed.
引用
收藏
页码:206 / +
页数:2
相关论文
共 50 条
  • [31] CO2 absorption at elevated pressures using a hollow fiber membrane contactor
    Dindore, VY
    Brilman, DWF
    Feron, PHM
    Versteeg, GF
    JOURNAL OF MEMBRANE SCIENCE, 2004, 235 (1-2) : 99 - 109
  • [32] Emulsion-liquid-membrane extraction of copper using a hollow-fiber contactor
    Hu, SYB
    Wiencek, JM
    AICHE JOURNAL, 1998, 44 (03) : 570 - 581
  • [33] Liposome preparation using a hollow fiber membrane contactor-Application to spironolactone encapsulation
    Laouini, A.
    Jaafar-Maalej, C.
    Sfar, S.
    Charcosset, C.
    Fessi, H.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2011, 415 (1-2) : 53 - 61
  • [34] Numerical evaluation of the ozonation process in a hollow fibre membrane contactor
    Cao, Yan
    Ghadiri, Mahdi
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2023, 170 : 817 - 823
  • [35] Potentialities of a dense skin hollow fiber membrane contactor for biogas purification by pressurized water absorption
    Belaissaoui, Bouchra
    Claveria-Baro, Joan
    Lorenzo-Hernando, Ana
    Zaidiza, David Albarracin
    Chabanon, Elodie
    Castel, Christophe
    Rode, Sabine
    Roizard, Denis
    Favre, Eric
    JOURNAL OF MEMBRANE SCIENCE, 2016, 513 : 236 - 249
  • [36] Carbon dioxide stripping from water through porous polysulfone hollow fiber membrane contactor
    Rahbari-Sisakht, M.
    Ismail, A. F.
    Rana, D.
    Matsuura, T.
    Emadzadeh, D.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2013, 108 : 119 - 123
  • [37] CFD modeling of CO2 capture by water-based nanofluids using hollow fiber membrane contactor
    Hajilary, Nasibeh
    Rezakazemi, Mashallah
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2018, 77 : 88 - 95
  • [38] Experimental study of carbon dioxide absorption into aqueous ammonia with a hollow fiber membrane contactor
    Cui, Zheng
    deMontigny, David
    JOURNAL OF MEMBRANE SCIENCE, 2017, 540 : 297 - 306
  • [39] Modeling and experimental study of CO2 absorption in a hollow fiber membrane contactor
    Zhang, Hong-Yan
    Wang, Rong
    Liang, David Tee
    Tay, Joo Hwa
    JOURNAL OF MEMBRANE SCIENCE, 2006, 279 (1-2) : 301 - 310
  • [40] Modeling and experimental study of CO2 absorption in a hollow fiber membrane contactor
    School of Civil and Environmental Engineering, Nanyang Technological University, Singapore, 639798, Singapore
    不详
    J. Membr. Sci., 2006, 1-2 (301-310):