Numerical Study of Boiler Feed Water Deoxygenation using Hollow Fiber Membrane Contactor

被引:0
|
作者
Zhang, Xiaoguang [1 ,2 ]
Wang, Shigang [1 ]
机构
[1] Qingdao Univ Sci & Technol, Coll Electromech Engn, 99 Songling Rd, Qingdao 266061, Peoples R China
[2] Qingdao Univ Sci & Technol, Shandong Provincial Key Lab Polymer Mat Adv Manuf, Qingdao 266061, Peoples R China
来源
关键词
mass transfer coefficient; dissolved oxygen; gauss distribution; packing density; hollow fiber membrane contactor; MASS-TRANSFER; MODULES; PERFORMANCE; FLOW;
D O I
10.4028/www.scientific.net/KEM.561.206
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Removal of dissolved oxygen from feed water is a necessary process in power industry. The hollow fiber membrane contactor is more efficient and pollution-free compared with some traditional methods. In this paper, hollow fiber is modeled by random distribution, and Gaussian function N(R, sigma) was used to model the polydisperse out radii of hollow fiber. This paper discussed the influence of different sigma on mass transfer coefficient with fiber packing density ranging from 0.1 to 0.4. It was found that, the effect of different sigma on the logarithmic mean Sherwood number decreased with increasing fiber packing density. When the packing density increased to 0.4, the removal of dissolved oxygen could meet the requirement of power industry, no matter how much value the sigma was. With the sigma increasing, the deviation of max and min Sherwood number from the average value increased gradually, except when the sigma was 0.05. This paper deduces there is a best value of sigma for membrane contactor when the fiber distribution is randomly distributed.
引用
收藏
页码:206 / +
页数:2
相关论文
共 50 条
  • [1] Boiler feed water deoxygenation using hollow fiber membrane contactor
    Shao, Jiahui
    Liu, Huifeng
    He, Yiliang
    DESALINATION, 2008, 234 (1-3) : 370 - 377
  • [2] Control of oxygen concentration in water using a hollow fiber membrane contactor
    Dongjae Jeong
    Mihye Yun
    Jeongsik Oh
    Ina Yum
    Yongtaek Lee
    Korean Journal of Chemical Engineering, 2010, 27 : 939 - 943
  • [3] Control of oxygen concentration in water using a hollow fiber membrane contactor
    Jeong, Dongjae
    Yun, Mihye
    Oh, Jeongsik
    Yum, Ina
    Lee, Yongtaek
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2010, 27 (03) : 939 - 943
  • [4] Water deoxygenation using a hollow fiber membrane contactor to prevent pipe corrosion for sustainable management of district heating systems: A pilot-scale study
    Lee, Jiho
    Baek, Soo-Min
    Boo, Chanhee
    Son, Aseom
    Jung, Hoseok
    Park, Sung Soo
    Hong, Seok Won
    JOURNAL OF CLEANER PRODUCTION, 2020, 277
  • [5] Water deoxygenation using hollow fiber membrane module with nitrogen as inert gas
    Martic, Igor
    Maslarevic, Aleksandar
    Mladenovic, Sasa
    Lukic, Uros
    Budimir, Stevan
    DESALINATION AND WATER TREATMENT, 2015, 54 (06) : 1563 - 1567
  • [6] Ethanol-water separation in hollow fiber membrane contactor
    Lin, Lan
    Zhang, Guoliang
    Meng, Qin
    Huagong Xuebao/Journal of Chemical Industry and Engineering (China), 2007, 58 (11): : 2822 - 2827
  • [7] CO2 absorption using benzylamine as absorbent and promoter in a hollow fiber membrane contactor: A numerical study
    Eskandari, Masoud
    Khaksar, Seyed Amir Nezam
    Keshavarz, Peyman
    JOURNAL OF CO2 UTILIZATION, 2022, 66
  • [8] A theoretical study of dense gas extraction using a hollow fiber membrane contactor
    Gabeli-Nan, A
    Hwang, B
    JOURNAL OF SUPERCRITICAL FLUIDS, 2006, 37 (02): : 157 - 172
  • [9] CO2 capture by modified hollow fiber membrane contactor: Numerical study on membrane structure and membrane wettability
    Abdolahi-Mansoorkhani, Hamed
    Seddighi, Sadegh
    FUEL PROCESSING TECHNOLOGY, 2020, 209 (209)
  • [10] Evaluation of an ozone diffusion process using a hollow fiber membrane contactor
    Schmitt, Alice
    Mendret, Julie
    Brosillon, Stephan
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2022, 177 : 291 - 303