Influence of additional astigmatism on distance-corrected near visual acuity and reading performance

被引:24
|
作者
Casagrande, Maria [1 ]
Baumeister, Martin [1 ]
Buehren, Jens [1 ]
Klaproth, Oliver K. [1 ]
Titke, Christine [1 ]
Kohnen, Thomas [1 ]
机构
[1] Goethe Univ Frankfurt, Dept Ophthalmol, D-60590 Frankfurt, Germany
关键词
MONOFOCAL INTRAOCULAR LENSES; PUPIL SIZE; VISION; EYES; TROPICAMIDE; REFRACTION; SPEED;
D O I
10.1136/bjophthalmol-2013-303066
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim To investigate the effect of astigmatism on near vision performance. Methods In a consecutive case series 23 eyes of 23 participants were fogged with 0 D, -0.75 D and -1.5 D of with-the-rule (WTR) and against-the-rule (ATR) astigmatism (cylindrical lenses without spherical compensation). All subjects were cyclopleged and distance corrected. Reading acuity (RAc) and speed (RS) were measured with standardised sentences, near visual acuity (NVA) was assessed using single optotypes (Snellen E), all presented on a thin film transistor display using the Salzburg Reading Desk (SRD). Data were analysed using Wilcoxon-matched-pairs test, regression analysis and Bland-Altman analysis. Results An increasing amount of astigmatism resulted in a decreased NVA (p=0.16 for -0.75 D, p=0.005 for -1.5 D) and RAc (p=0.002 for -0.75 D, p=0.014 for -1.5 D). WTR astigmatism caused a reduced NVA, RAc and lower RS compared with ATR astigmatism (p<0.001). NVA was better than RAc with no astigmatism, -0.75 D WTR and -1.5 D WTR (p=0.03 for 0 D, p<0.001 for -0.75 D, p=0.03 for -1.5 D). There was no difference between NVA and RAc for -0.75 D ATR and -1.5 D ATR (p=0.06 for -0.75 D, p=0.5 for -1.5 D). Conclusions WTR astigmatism results in reduced reading parameters and NVA for -0.75 D and -1.5 D astigmatism compared with corresponding ATR astigmatism and no astigmatism added. No beneficial effect of astigmatism was detected.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 50 条
  • [21] EXAMINATION OF INFLUENCE OF DIFFERENT PRISMS ON VISUAL-ACUITY FOR DISTANCE
    FAUHL, GM
    HAASE, W
    RASSOW, B
    ALBRECHT VON GRAEFES ARCHIV FUR KLINISCHE UND EXPERIMENTELLE OPHTHALMOLOGIE, 1972, 185 (01): : 66 - &
  • [22] Relation of reading performance to visual acuity and perceived reading ability in low vision
    Massof, RW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U305 - U305
  • [23] The effect of low predicted/calculated postoperative keratometry on corrected distance visual acuity after LASIK
    Janbatian, Hrag
    Drake, Ryan
    Melki, Samir
    Brenner, Jason
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (12): : 1770 - 1776
  • [24] Influence of loupes and age on the near visual acuity of practicing dentists
    Eichenberger, Martina
    Perrin, Philippe
    Neuhaus, Klaus W.
    Bringolf, Ueli
    Lussi, Adrian
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (03)
  • [25] Age-related changes in baseline reading acuity and speed as measured using RADNER Reading Charts in healthy eyes with best corrected ETDRS distance acuity
    Radner, Wolfgang
    Benesch, Thomas
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2019, 103 (10) : 176 - 181
  • [26] Higher-order aberrations and best-corrected visual acuity in Native American children with a high prevalence of astigmatism
    Miller, Joseph M.
    Harvey, Erin M.
    Schwiegerling, Jim
    JOURNAL OF AAPOS, 2015, 19 (04): : 352 - 357
  • [27] Effect of illuminance on home measurements of near and distance visual acuity and contrast sensitivity
    Awidi, Abdelhalim
    Almidani, Louay
    Mihailovic, Aleksandra
    Swaminathan, Siva Ram
    Yuan, Zhuochen
    Ramulu, Pradeep Y.
    Awidi, Abdelhalim
    Almidani, Louay
    Mihailovic, Aleksandra
    Swaminathan, Siva Ram
    Yuan, Zhuochen
    Ramulu, Pradeep Y.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [28] Comparison of distance and near visual acuity in patients with vision loss due to cataract
    Mercado, Carmel L.
    Doroslovacki, Pavle
    Wang, Jiangxia
    Siddiqui, Aazim A.
    Kolker, Andrew F.
    Kolker, Richard J.
    INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (01) : 169 - 172
  • [29] Comparison of distance and near visual acuity in patients with vision loss due to cataract
    Carmel L. Mercado
    Pavle Doroslovački
    Jiangxia Wang
    Aazim A. Siddiqui
    Andrew F. Kolker
    Richard J. Kolker
    International Ophthalmology, 2017, 37 : 169 - 172
  • [30] Visual impairment in Australia: Distance visual acuity, near vision, and visual field findings of the Melbourne Visual Impairment Project
    Taylor, HR
    Livingston, PM
    Stanislavsky, YL
    McCarty, CA
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 123 (03) : 328 - 337