Energy Flexible Buildings - The impact of building design on energy flexibility

被引:2
|
作者
Weiss, T. [1 ]
机构
[1] AEE INTEC, Gleisdorf, Austria
关键词
D O I
10.1088/1755-1315/323/1/012009
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Thermal load management has substantial theoretical potential for energy flexibility. To use the inherent flexibility in buildings, for example, district heating companies could temporarily control the heating system of buildings to switch-off or preheat dwellings in the morning to avoid using peak load gas boilers. The "thermal flexibility" in this study indicates the tolerance of buildings towards the changes of its heating system operation according to an external signal. The focus of this investigation is to give an overview of "thermal flexibility" of residential buildings in Austria from 1920 - 2020 with different envelope qualities, construction types and heating systems. Existing residential buildings in Austria usually have a high thermal mass within their massive brick or concrete primary structure, and therefore their indoor thermal conditions react slowly to operative changes in the supply of thermal energy. Depending on the buildings ability to retain or store heat inside the building envelope, space heating can be used to offer energy flexibility. Among other factors, especially the quality of the thermal envelope, the thermal capacity of the building, the sluggishness of the heat delivery system and passive solar gains are crucial for keeping indoor thermal comfort. Dynamic building simulation in IDA ICE is used to evaluate the potential of selected building typologies to shift heating loads away from peak demand periods. Potentials of various building archetypes according to the EU-Tabula building database to time-shift the operation of the heating system are pointed out respecting occupants' comfort.
引用
下载
收藏
页数:9
相关论文
共 50 条
  • [31] Energy flexibility quantification of grid-responsive buildings: Energy flexibility index and assessment of their effectiveness for applications
    Tang, Hong
    Wang, Shengwei
    ENERGY, 2021, 221
  • [32] Potential of energy flexible buildings: Evaluation of DSM strategies using building thermal mass
    Sanchez Ramos, Jose
    Pavon Moreno, Mcarmen
    Guerrerot Delgado, Mcarmen
    Alvarez Dominguez, Servando
    Cabeza, Luisa F.
    ENERGY AND BUILDINGS, 2019, 203
  • [33] Are building users prepared for energy flexible buildings?-A large-scale survey in the Netherlands
    Li, Rongling
    Dane, Gamze
    Finck, Christian
    Zeiler, Wim
    APPLIED ENERGY, 2017, 203 : 623 - 634
  • [34] Design of isolated multi-energy complementary building energy system based on flexible load
    Liu, Yanfeng
    Liu, Zhengxue
    Luo, Xi
    Hu, Liang
    Wang, Yaxing
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (06): : 24 - 32
  • [35] Energy flexibility quantification of grid-responsive buildings: Energy flexibility index and assessment of their effectiveness for applications
    Tang, Hong
    Wang, Shengwei
    Energy, 2021, 221
  • [36] Evaluating the impact of thermostat control strategies on the energy flexibility of residential buildings for space heating
    Kun Zhang
    Michaël Kummert
    Building Simulation, 2021, 14 : 1439 - 1452
  • [37] Evaluating the impact of thermostat control strategies on the energy flexibility of residential buildings for space heating
    Zhang, Kun
    Kummert, Michael
    BUILDING SIMULATION, 2021, 14 (05) : 1439 - 1452
  • [38] Achievable Energy Flexibility Forecasting of Buildings Equipped With Integrated Energy Management System
    Zhang, Peng
    Lu, Xiaoxing
    Li, Kangping
    IEEE ACCESS, 2021, 9 : 122589 - 122599
  • [39] ENERGY DESIGN OF OFFICE BUILDINGS
    MISURIELLO, H
    DERINGER, JJ
    PROGRESSIVE ARCHITECTURE, 1982, 63 (06): : 109 - 113
  • [40] BUILDING DESIGN AND ENERGY
    OSULLIVAN, P
    RIBA JOURNAL-ROYAL INSTITUTE OF BRITISH ARCHITECTS, 1977, 84 (07): : 307 - 307