This paper presents an investigation into the recurring failures of pad-mounted generator step-up transformers that have been experienced by Exelon Wind at a wind farm in Northern Texas. Observations indicate that the transformer failures are typically a result of contaminated oil due to arcing within the transformer expulsion fuse tube. To determine the underlying cause of this phenomena, S&C Electric Company installed digital monitoring equipment to capture electrical and thermal data at a pad-mounted generator step-up transformer over a four-month period. Electrical data was also captured at the point of interconnect between the wind farm and the local utility. The data captured in this time frame revealed that high-current surges and current cycling frequently occurred due to the WTG cycling on and off from the highly variable wind speeds in the area. High-current surges and current cycling places thermomechanical stress on the transformer and expulsion fuse links, which may ultimately lead to the types of failures experienced at this location.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Adjusting the voltage step-up ratio of a magnetoelectric composite transformer
    Lue Li
    Guo YangYang
    Zhou JianPing
    Wang Pan
    Liu Peng
    Chen XiaoMing
    CHINESE SCIENCE BULLETIN, 2011, 56 (07): : 700 - 703
  • [32] The effects of geometrical factors on the step-up ratio in piezoelectric transformer
    Yoon, M. -S.
    Yoon, T-S.
    Kim, J. -R.
    Choi, Y-G.
    Ur, S. -C.
    THERMEC 2006, PTS 1-5, 2007, 539-543 : 3319 - +
  • [33] High efficiency Step-Up HVDC converter for photovoltaic generator
    Sawicki, Jean-Paul
    Petit, Pierre
    Zegaoui, Abdallah
    Aillerie, Michel
    Charles, Jean-Pierre
    TERRAGREEN 2012: CLEAN ENERGY SOLUTIONS FOR SUSTAINABLE ENVIRONMENT (CESSE), 2012, 18 : 1593 - 1600
  • [34] Lightning Overvoltage Protection of Step-Up Transformer Inside a Nacelle of Onshore New-Generation Wind Turbines
    Sarajcev, Petar
    Meglic, Antun
    Goic, Ranko
    ENERGIES, 2021, 14 (02)
  • [35] Failure analysis of shear pins in wind turbine generator
    Sankar, S.
    Nataraj, M.
    Raja, V. Prabhu
    ENGINEERING FAILURE ANALYSIS, 2011, 18 (01) : 325 - 339
  • [36] A Review of Failure Mechanisms in Wind Turbine Generator Systems
    Shipurkar, Udai
    Ma, Ke
    Polinder, Henk
    Blaabjerg, Frede
    Ferreira, Jan A.
    2015 17TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'15 ECCE-EUROPE), 2015,
  • [37] Probabilistic analysis of switching transients due to vacuum circuit breaker operation on wind turbine step-up transformers
    Ghasemi, Sajjad
    Allahbakhshi, Mehdi
    Behdani, Behzad
    Tajdinian, Mohsen
    Popov, Marjan
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 182
  • [38] The efferent path of the nervous system regarded as a step-up transformer of energy
    Pike, FH
    SCIENCE, 1920, 52 : 111 - 112
  • [39] Electrical analysis of step-up multi-layered piezoelectric transformer
    Shin, Hoonbum
    Kasemsuwan, Varakorn
    Ahn, Hyungkeun
    El Nokali, M.
    Han, Deuk-Young
    JOURNAL OF ELECTROCERAMICS, 2006, 17 (2-4) : 585 - 590
  • [40] Optimized pulse transformer for step-up DC-DC converter
    The Vinh Nguyen
    Thanh Vinh Vo
    Petit, Pierre
    Aillerie, Michel
    Ngoc Thang Pham
    INTERNATIONAL CONFERENCE ON TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY, TMREES17, 2017, 119 : 930 - 937