Hepatic artery reconstruction in living donor liver transplantation: strategy of the extension of graft or recipient artery

被引:8
|
作者
Okochi, Masayuki [1 ]
Okochi, Hiromi [1 ]
Sakaba, Takao [1 ]
Ueda, Kazuki [1 ]
机构
[1] Teikyo Univ, Dept Plast & Reconstruct Surg, Itabashi Ku, 2-11-1 Kaga, Tokyo 1738605, Japan
关键词
Liver transplantation; hepatic artery; reconstruction; anastomosis; microsurgery; INTERPOSITIONAL VASCULAR GRAFT; MICROSURGICAL RECONSTRUCTION; RADIAL ARTERY;
D O I
10.1080/2000656X.2019.1582426
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In living donor liver transplantation (LDLT) patients, the reconstruction of insufficiently long hepatic artery (HA) is difficult. However, no report has described the relationship between the length of HA and its reconstructive procedure. Herein, we aimed to identify the risk factors for the requirement of additional reconstructive procedures of direct anastomosis. Sixty-eight HA reconstructions in LDLT were conducted (37, men; 31, women). The causes of LDLT were hepatitis (n = 36), biliary atresia (n = 13), and primary biliary cirrhosis (n = 12). The graft HA comprised the right HA (n = 37) and left HA (n = 31). The recipient HA comprised the right HA (n = 39), left HA (n = 28), and right gastro-omental artery (n = 1). Two cases had graft HAs measuring 8 mm or more. The gap between the graft and recipient HA was 6 mm or more in nine cases. In 63 cases, direct anastomosis was performed. The extension of graft HA was performed using radial graft (n = 1) and two-step method (n = 1). The extension of recipient HA was performed using arterial graft (n = 2) extraanatomical recipient artery. Less than 8 mm length of graft HA (OR, 84) and 6 mm or greater gap between the recipient and graft HA (OR, 46.0) were identified as the risk factors for the need of additional procedures of direct anastomosis. We must always pay attention to the length of the graft and donor HA. To perform HA reconstruction safely, we should always consider using arterial grafts, extra-anatomical recipient artery, or the two-step method.
引用
下载
收藏
页码:216 / 220
页数:5
相关论文
共 50 条
  • [41] Hepatic Arterial Reconstruction Using Right Gastroepiploic Artery in Living Donor Liver Transplantation
    Ozer, A.
    Aktas, H.
    Eren, N.
    Karakayali, H.
    Emiroglu, R.
    TRANSPLANTATION PROCEEDINGS, 2018, 50 (10) : 3559 - 3561
  • [42] TECHNICAL ASPECTS OF HEPATIC ARTERY RECONSTRUCTION WITHOUT MICROSCOPE IN LIVING DONOR LIVER TRANSPLANTATION
    Slim, Abdallah
    Lauterio, Andrea
    Giacomoni, Alessandro
    Di Sandro, Stefano
    Mangoni, Lacopo
    Mihaylov, Plamen
    Al Kofahi, Mohamed
    De Carlis, Luciano
    LIVER TRANSPLANTATION, 2009, 15 (07) : S229 - S229
  • [43] The Effects of Gabexate Mesilate on the Microsurgical Reconstruction of the Hepatic Artery in Living Donor Liver Transplantation
    Miyagi, S.
    Enomoto, Y.
    Sekiguchi, S.
    Kawagishi, N.
    Satomi, S.
    TRANSPLANTATION PROCEEDINGS, 2010, 42 (10) : 4158 - 4160
  • [44] Elimination of hepatic artery thrombosis in living donor liver. Transplantation with microvascular reconstruction
    Millis, JM
    Cronin, DC
    Newell, KA
    Bruce, DS
    Woodle, ES
    Siegel, C
    Brady, L
    Thistlethwaite, JR
    HEPATOLOGY, 1998, 28 (04) : 264A - 264A
  • [45] Living donor liver transplantation for intrahepatic arteriovenous fistula with hepatic artery reconstruction using the right gastroepiploic artery
    Uchiyama, Hideaki
    Shirabe, Ken
    Yoshizumi, Tomoharu
    Ikegami, Toru
    Harimoto, Norifumi
    Itoh, Shinji
    Kimura, Koichi
    Okabe, Hirohisa
    Maehara, Yoshihiko
    LIVER TRANSPLANTATION, 2016, 22 (04) : 552 - 556
  • [46] Anatomic variation of the right hepatic artery and its reconstruction for living donor liver transplantation using right lobe graft
    Ahn, CS
    Lee, SG
    Hwang, S
    Moon, DB
    Ha, TY
    Lee, YJ
    Park, KM
    Kim, KH
    Kim, YD
    Kim, KK
    TRANSPLANTATION PROCEEDINGS, 2005, 37 (02) : 1067 - 1069
  • [47] Two-step hepatic artery reconstruction for a hepatic artery lacking in length for the use of a microclamp in living donor liver transplantation
    Okochi, Masayuki
    Kenjo, Akira
    Asai, Emiko
    Ueda, Kazuki
    Gotoh, Mitsukazu
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2016, 24 : 70 - 72
  • [48] An alternative method of arterial reconstruction in pediatric living donor liver transplantation with the recipient right gastroepiploic artery
    Tannuri, U
    Maksoud, JG
    Silva, MM
    Suzuki, L
    Santos, MM
    Gibelli, NE
    Ayoub, AA
    Velhote, MCP
    Pinho-Apezzato, ML
    Maksoud, JG
    PEDIATRIC TRANSPLANTATION, 2006, 10 (01) : 101 - 104
  • [49] Initial Experience with Microsurgical Reconstruction of Hepatic Artery during Pediatric Living Donor Liver Transplantation
    Garcia-Huidobro, Maria A.
    Contreras, Rodrigo A.
    Pattillo, Juan C.
    Jarufe, Nicolas P.
    Gana, Juan C.
    Soriano, Humberto E.
    Dellepiane, Paulina E.
    Martinez, Jorge A.
    LIVER TRANSPLANTATION, 2011, 17 (06) : S301 - S301
  • [50] HEPATIC ARTERY RECONSTRUCTION WITHOUT MICROSCOPE IN LIVING DONOR LIVER TRANSPLANTATION. TECHNICAL ASPECTS
    Slim, Abdallah
    Lauterio, Andrea
    Giacomoni, Alessandro
    Di Sandro, Stefano
    Aseni, Paolo
    Mangoni, Iacopo
    Mihaylov, Plamen
    Kofahi, Mohamed Al
    De Carlis, Luciano
    TRANSPLANT INTERNATIONAL, 2009, 22 : 207 - 208