Silicon nanoparticles coated with an epitope-imprinted polymer for fluorometric determination of cytochrome c

被引:33
|
作者
Zhang, Xue-Mei [1 ]
Qin, Ya-Ping [1 ]
Ye, Hong-Li [1 ]
Ma, Xiao-Tong [1 ]
He, Xi-Wen [1 ]
Li, Wen-You [1 ,2 ]
Zhang, Yu-Kui [1 ,3 ]
机构
[1] Nankai Univ, Tianjin Key Lab Biosensing & Mol Recognit, State Key Lab Med Chem Biol, Coll Chem,Res Ctr Analyt Sci, Tianjin 300071, Peoples R China
[2] Collaborat Innovat Ctr Chem Sci & Engn Tianjin, Tianjin 300071, Peoples R China
[3] Chinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatog Res & Anal Ctr, Dalian 116023, Peoples R China
基金
中国国家自然科学基金;
关键词
Composite; Fluorescence quenching; Dual epitope imprinting; Recognition; Molecularly imprinted polymer; Chelation; Discrimination ability; Fixation methods; CDTE QUANTUM DOTS; TARGET PROTEIN; FLUORESCENT; WATER; RECOGNITION; CAPTURE; SENSOR; CELL;
D O I
10.1007/s00604-018-2724-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The authors describe a composite consisting of silicon nanoparticles that were first coated with SiO2 and then with a molecularly imprinted polymer (SiNP@SiO2@MIP). The MIP was generated by dual epitope imprinting such that it can recognize cytochrome c (Cyt c). The MIP on the NPs was prepared from the functional monomer zinc(II) acrylate (ZnA), the crosslinker ethylene glycol dimethacrylate and the initiator 2,2'-azoisobutyronitrile. Dual epitope templates for Cyt c included (a) a C-terminal nonapeptide (AYLKKATNE), and (b) an N-terminal nonapeptide (GDVEKGKKI). The chelation between Zn(II) of ZnA and the amino groups or hydroxy groups of the template nonapeptides warrants good recognition and capture of Cyt c. The fluorescence originating from SiNPs has excitation/emission peaks at 360/480 nm and is quenched by Cyt c in the 0.50-40.0 mu M concentration range. The correlation coefficient for the calibration plot of the imprinted NPs is 0.9937. The detection limit is 0.32 +/- 0.01 mu M, the precisions of six replicate detections at levels of 0.5, 20 and 40 mu MCyt c are 3.2, 2.7 and 2.8%, respectively, and the imprinting factor is 2.43. Compared to single epitope template imprinting, dual epitope imprinting results in improved selectivity. The imprinted nanoparticles can discriminate Cyt c even if one amino acid is mismatched. The method was applied to the determination of Cyt c in spiked diluted human serum and gave recoveries between 94.0 and 107.5%.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Fluorometric determination of doxycycline based on the use of carbon quantum dots incorporated into a molecularly imprinted polymer
    Feng, Xiaotong
    Ashley, Jon
    Zhou, Tongchang
    Sun, Yi
    MICROCHIMICA ACTA, 2018, 185 (11)
  • [42] Fluorometric determination of doxycycline based on the use of carbon quantum dots incorporated into a molecularly imprinted polymer
    Xiaotong Feng
    Jon Ashley
    Tongchang Zhou
    Yi Sun
    Microchimica Acta, 2018, 185
  • [43] Sensing HIV related protein using epitope imprinted hydrophilic polymer coated quartz crystal microbalance
    Lu, Chun-Hua
    Zhang, Yan
    Tang, Shui-Fen
    Fang, Zhi-Bin
    Yang, Huang-Hao
    Chen, Xi
    Chen, Guo-Nan
    BIOSENSORS & BIOELECTRONICS, 2012, 31 (01): : 439 - 444
  • [44] Molecularly Imprinted Polymer-Coated CdTe Quantum Dots for Fluorometric Detection of Sulfonamide Antibiotics in Food Samples
    Mortari, Bianca
    Khan, Sabir
    Wong, Ademar
    Sotomayor, Maria Del Pilar Taboada
    BIOSENSORS-BASEL, 2023, 13 (09):
  • [45] Cardiac Troponin T capture and detection in real-time via epitope-imprinted polymer and optical biosensing (vol 106, pg 93, 2018)
    Palladino, P.
    Minunni, M.
    Scarano, S.
    BIOSENSORS & BIOELECTRONICS, 2019, 130 : 427 - 427
  • [46] Magnetic nanoparticles coated with a molecularly imprinted polymer via manganese-doped ZnS:Mn quantum dots for the determination of Triflumuron
    Chen, Zhenkun
    Feng, Tian
    Cheng, Xiaomin
    POLYMER-PLASTICS TECHNOLOGY AND MATERIALS, 2024, 63 (09): : 1096 - 1105
  • [47] Molecularly imprinted upconversion nanoparticles for highly selective and sensitive sensing of Cytochrome c
    Guo, Ting
    Deng, Qiliang
    Fang, Guozhen
    Liu, Cuicui
    Huang, Xuan
    Wang, Shuo
    BIOSENSORS & BIOELECTRONICS, 2015, 74 : 498 - 503
  • [48] Fluorometric microplate-based dimethoate assay using CdSe/ZnS quantum dots coated with a molecularly imprinted polymer
    Yukun Yang
    Yuanyuan Chang
    Yuanyuan Guo
    Ligang Yu
    Guohua Zhang
    Doudou Zhai
    Xiaomin Wang
    Xiaotao Sun
    Microchimica Acta, 2019, 186
  • [49] Fluorometric microplate-based dimethoate assay using CdSe/ZnS quantum dots coated with a molecularly imprinted polymer
    Yang, Yukun
    Chang, Yuanyuan
    Guo, Yuanyuan
    Yu, Ligang
    Zhang, Guohua
    Zhai, Doudou
    Wang, Xiaomin
    Sun, Xiaotao
    MICROCHIMICA ACTA, 2019, 186 (08)
  • [50] Epitope imprinted polymer nanoparticles containing fluorescent quantum dots for specific recognition of human serum albumin
    Yi-Zhi Wang
    Dong-Yan Li
    Xi-Wen He
    Wen-You Li
    Yu-Kui Zhang
    Microchimica Acta, 2015, 182 : 1465 - 1472