Geant4 Simulation Study of Dose Distribution and Energy Straggling for Proton and Carbon Ion Beams in Water

被引:0
|
作者
Zhao, Qiang [1 ]
Zhang, Zheng [1 ]
Li, Yang [1 ]
机构
[1] North China Elect Power Univ, Sch Nucl Sci & Engn, Beijing Key Lab Pass Safety Technol Nucl Energy, Beijing 102206, Peoples R China
关键词
Monte Carlo simulation; dose distribution; geant4; Bragg peak; THERAPY; RADIOTHERAPY; MODEL; FRAGMENTATION; NE-20;
D O I
10.1051/matecconf/20166502002
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Dose distribution and energy straggling for proton and carbon ion beams in water are investigated by using a hadrontherapy model based on the Geant4 toolkit. By gridding water phantom in NxNxN voxels along X, Y and Z axes, irradiation dose distribution in all the voxels is calculated. Results indicate that carbon ion beams have more advantages than proton beams. Proton beams have bigger width of the Bragg peak and broader lateral dose distribution than carbon ion beams for the same position of Bragg peaks. Carbon ion has a higher local ionization density and produces more secondary electrons than proton, so carbon ion beams can achieve a higher value of relative biological effectiveness.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Validation of Geant4 Simulation of Proton Energy Straggling: First Results
    Han, Min Cheol
    Pia, Maria Grazia
    Saracco, Paolo
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [2] Proton pencil beam dose distribution simulation by Geant4
    Yang, Y
    Coutrakon, G
    Wang, N
    Shahnazi, K
    Miller, D
    MEDICAL PHYSICS, 2003, 30 (06) : 1520 - 1520
  • [3] A GEANT4 Simulation of Light-Ion Beams in Water
    Johnson, D.
    Ahmad, S.
    MEDICAL PHYSICS, 2011, 38 (06) : 3652 - +
  • [4] Influence of Geant4 parameters on dose distribution and computation time for carbon ion therapy simulation
    Zahra, Nabil
    Frisson, Thibault
    Grevillot, Loic
    Lautesse, Philippe
    Sarrut, David
    PHYSICA MEDICA, 2010, 26 (04) : 202 - 208
  • [5] COMPARISON BETWEEN PROTON AND HELIUM ION BEAMS PERFORMED WITH THE SIMULATION SOFTWARE GEANT4
    Stroebele, J.
    Schreiner, T.
    Georg, D.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S535 - S535
  • [6] Dose calculation accuracy of Gate/Geant4 on transverse dose profiles of proton pencil beams in water
    Resch, A.
    Carlino, A.
    Fuchs, H.
    Elia, A.
    Stock, M.
    Georg, D.
    Grevillot, L.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S970 - S971
  • [7] Verification of the dose distributions with GEANT4 simulation for proton therapy
    Aso, T
    Kimura, A
    Tanaka, S
    Yoshida, H
    Kanematsu, N
    Sasaki, T
    Akagi, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 896 - 901
  • [8] Verification of the dose distributions with GEANT4 simulation for proton therapy
    Aso, T
    Kimura, A
    Tanaka, S
    Yoshida, H
    Kanematsu, N
    Sasaki, T
    Akagi, T
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2138 - 2142
  • [9] GEANT4 simulation of exit energy in proton medical imaging
    Silva, R. C. L.
    Denyak, V.
    Schelin, H. R.
    Hoff, G.
    Paschuk, S. A.
    Setti, J. A. P.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 167
  • [10] Yields of positron and positron emitting nuclei for proton and carbon ion radiation therapy: A simulation study with GEANT4
    Lau, Andy
    Chen, Yong
    Ahmad, Salahuddin
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2012, 20 (03) : 317 - 329