Amperometric Determination of Dopamine Using Activated Screen-Printed Carbon Electrodes

被引:16
|
作者
Pan, Deng [1 ]
Rong, Shengzhong [2 ]
Zhang, Guangteng [3 ]
Zhang, Yannan [4 ]
Zhou, Qiang [1 ]
Liu, Fenghai [2 ]
Li, Miaojing [2 ]
Chang, Dong [5 ]
Pan, Hongzhi [1 ]
机构
[1] Harbin Med Univ, Dept Nutr & Food Hyg, Sch Publ Hlth, Harbin 150081, Heilongjiang, Peoples R China
[2] Mudanjiang Med Univ, Sch Publ Hlth, Mudanjiang 157011, Heilongjiang, Peoples R China
[3] Third Cent Hosp Tianjin, Dept Nutr, Tianjin 300170, Peoples R China
[4] Capital Med Univ, Beijing Key Lab Environm Toxicol, Sch Publ Hlth, Beijing 100069, Peoples R China
[5] Harbin Med Univ, Affiliated Hosp 1, Clin Lab, Harbin 150001, Heilongjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Screen-printed Carbon Electrodes; Activated; Dopamine; Electrochemical Detection; ASCORBIC-ACID; ELECTROCHEMICAL DETERMINATION; STRIATAL DOPAMINE; LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; URIC-ACID; SENSOR; OPTIMIZATION; DISEASE;
D O I
10.5796/electrochemistry.83.725
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this paper, we determined dopamine using screen-printed carbon electrodes (SPCEs) which was activated by 0.1 mol L-1 NaOH solution deposited on the electrode to improve the capabilities of detection. Cyclic voltammetry and differential pulse voltammetry were used to investigate the electrochemical behavior of dopamine. Cyclic voltammetry studies indicated that electrochemical oxidation of dopamine at the surface of SPCEs was decided by pH value. Different pulse voltammetry for dopamine oxidation at the SPCEs yielded a well-defined oxidation peak at 0.2V in 0.1 mol L-1 phosphate buffer (pH 5.0). The proposed electrodes showed good selectivity for dopamine and a good linear relationship between dopamine concentration and oxidation current was obtained within the range of 2.0 x 10(-7) mol L-1 -300.0 x 10(-6) mol L-1 with a detection limit of 6.7 x 10(-8) mol L-1 (S/N = 3). In addition, the results showed that the precision in terms of reproducibility was 2.8% in the case of the activated SPCEs. The recovery rates of this technology were 95.40 to 103.4% with a relative standard deviation (RSD) was 2.7%-4.6%, indicating that this method can completely be used for detecting the practical dopamine injection sample. (C) The Electrochemical Society of Japan, All rights reserved.
引用
收藏
页码:725 / 729
页数:5
相关论文
共 50 条
  • [21] Amperometric biosensors based on nafion coated screen-printed electrodes for the determination of cholinesterase inhibitors
    Gogol, EV
    Evtugyn, GA
    Marty, JL
    Budnikov, HC
    Winter, VG
    TALANTA, 2000, 53 (02) : 379 - 389
  • [22] Amperometric determination of tyrosinase catecholase activity using a screen-printed electrode
    Cui, Yue
    Barford, John P.
    Renneberg, Reinhard
    CHEMIA ANALITYCZNA, 2007, 52 (01): : 5 - 14
  • [23] AMPEROMETRIC DETERMINATION OF ANTIDEPRESSANTS USING MONOAMINE OXIDASE AMPEROMETRIC BIOSENSORS BASED ON SCREEN-PRINTED ELECTRODES WITH MULTI-WALLED CARBON NANOTUBES AND NANOPARTICLES OF SILVER
    Brusnitsyn, D. V.
    Medyantseva, E. P.
    Varlamova, R. M.
    Maksimov, A. A.
    Fattakhova, A. N.
    Budnikov, H. C.
    UCHENYE ZAPISKI KAZANSKOGO UNIVERSITETA-SERIYA ESTESTVENNYE NAUKI, 2014, 156 (02): : 37 - 50
  • [24] PVA-AWP/tyrosinase functionalized screen-printed electrodes for dopamine determination
    Stoytcheva, M.
    Zlatev, R.
    Gonzalez Navarro, F. F.
    Velkova, Z.
    Gochev, V.
    Montero, G.
    Ayala Bautistaa, A. G.
    Toscano-Palomar, L.
    ANALYTICAL METHODS, 2016, 8 (26) : 5197 - 5203
  • [25] Reactive argon-plasma activation of screen-printed carbon electrodes for highly selective dopamine determination
    Cheunkar, Sarawut
    Oaew, Sukunya
    Parnsubsakul, Attasith
    Asanithi, Piyapong
    ANALYTICAL METHODS, 2022, 14 (42) : 4193 - 4201
  • [26] Comparison of different carbon ink based screen-printed electrodes towards amperometric immunosensing
    V. K. Rao
    M. K. Sharma
    P. Pandey
    K. Sekhar
    World Journal of Microbiology and Biotechnology, 2006, 22 : 1135 - 1143
  • [27] Comparison of different carbon ink based screen-printed electrodes towards amperometric immunosensing
    Rao, V. K.
    Sharma, M. K.
    Pandey, P.
    Sekhar, K.
    WORLD JOURNAL OF MICROBIOLOGY & BIOTECHNOLOGY, 2006, 22 (11): : 1135 - 1143
  • [28] Screen-Printed Carbon Electrodes with Macroporous Copper Film for Enhanced Amperometric Sensing of Saccharides
    Metelka, Radovan
    Vlasakova, Pavlina
    Smarzewska, Sylwia
    Guziejewski, Dariusz
    Vlcek, Milan
    Sys, Milan
    SENSORS, 2022, 22 (09)
  • [29] Determination of bioavailable lead in atmospheric aerosols using unmodified screen-printed carbon electrodes
    Silva-Neto, Habdias de A.
    Cardoso, Thiago M. G.
    Coltro, Wendell K. T.
    Urban, Roberta C.
    ANALYTICAL METHODS, 2019, 11 (38) : 4875 - 4881
  • [30] Design and development of an amperometric immunosensor based on screen-printed electrodes
    Mistry, Kalyan Kumar
    Layek, Keya
    Chell, Tarak Nath
    Chaudhuri, Chirasree Roy
    Saha, Hiranmay
    ANALYTICAL METHODS, 2016, 8 (15) : 3096 - 3101