Non-linear joint transform correlator for micro-displacement measurement using speckle patterns

被引:0
|
作者
Valdivieso Gonzalez, Luis G. [1 ]
Guerrero Bermudez, Jader E. [2 ]
Tepichin Rodriguez, Eduardo [1 ]
机构
[1] INAOE, Puebla 72840, Mexico
[2] Univ Ind Santander, Escuela Fis, Grp Opt & Tratamiento Senales, Bucaramanga 678, Colombia
关键词
Laser speckle; micro-displacements; nonlinear joint transform correlator;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This work presents a procedure for measuring displacements of tens micrometer, in one and two dimensions, based on the correlation between two speckle patterns. For this purpose, two objective speckle patterns are recorded by a digital camera one before and one after the object has been moved- and placed in the input plane of nonlinear joint transform correlator. Nonlinear transformation of the joint power spectrum allows a sharper correlation peak and a high signal to noise ratio. The autocorrelation peak coordinates of the first pattern are set as a reference for measuring shifts of the successive cross-correlation peak. One criterion for reliable measure is proposed. Results related with different distances sample-sensor and illuminating wavelengths at 632.8 nm and 543.5 nm are presented.
引用
收藏
页码:20 / 26
页数:7
相关论文
共 50 条
  • [31] Pseudo-Stokes Vector Correlation From Complex Signal Representation of a Speckle Pattern and Its Applications to Micro-Displacement Measurement
    Wang, W.
    Ishijima, R.
    Matsuda, A.
    Hanson, S. G.
    Takeda, M.
    STRAIN, 2010, 46 (01) : 12 - 18
  • [32] Non-linear speckle phase changes in the image plane caused by out of plane displacement
    Kolenovic, E
    Osten, W
    Jüptner, W
    OPTICS COMMUNICATIONS, 1999, 171 (4-6) : 333 - 344
  • [33] Non-linear speckle phase changes in the image plane caused by out of plane displacement
    Bremer Inst. Angew. Strahltechnik, Klagenfurter Str. 2, D-28359 Bremen, Germany
    Opt Commun, 4 (333-344):
  • [34] Two-dimensional micro-displacement measurement for laser coagulation using optical coherence tomography
    Kurokawa, Kazuhiro
    Makita, Shuichi
    Hong, Young-Joo
    Yasuno, Yoshiaki
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (01): : 170 - 190
  • [35] Extended the linear measurement range of four-quadrant detector by using modified polynomial fitting algorithm in micro-displacement measuring system
    Vo, Quangsang
    Zhang, Xiaodong
    Fang, Fengzhou
    OPTICS AND LASER TECHNOLOGY, 2019, 112 : 332 - 338
  • [36] MEASUREMENT OF AN ARBITRARY PARALLEL DISPLACEMENT OF A RIGID BODY BY USING POLYCHROMATIC SPECKLE PATTERNS
    THINH, VN
    TANAKA, SI
    OPTICS COMMUNICATIONS, 1977, 20 (03) : 367 - 369
  • [37] High-Resolution Micro-Displacement Measurement using a Fiber MZI Based on Microwave Photonics Filter
    Lei, Jing
    Song, Zixuan
    Cheng, Yunjie
    Wang, Yiping
    2019 CROSS STRAIT QUAD-REGIONAL RADIO SCIENCE AND WIRELESS TECHNOLOGY CONFERENCE (CSQRWC), 2019,
  • [38] Measurement of micro-displacement using white-light interference based on a spatial frequency domain algorithm
    School of Electronic Engineering and Photoelectric Technology, Nanjing University of Science and Technology, Nanjing 210094, China
    Infrared Laser Eng., 2008, 5 (874-877):
  • [39] High-precision micro-displacement measurement in a modified reversal shearing interferometer using vortex beams
    Gao, Hongwei
    Yang, Dong
    Hu, Xiaoning
    He, Weilin
    Yang, Zhongming
    Liu, Zhaojun
    OPTICS COMMUNICATIONS, 2023, 537