Determination of tannic acid by adsorptive anodic stripping voltammetry at porous pseudo-carbon paste electrode

被引:44
|
作者
Xu, Lijian [1 ,2 ]
He, Nongyue [1 ,2 ]
Du, Jingjing [2 ]
Deng, Yan [1 ,2 ]
机构
[1] Southeast Univ, State Key Lab Bioelect, Sch Biol Sci & Med Engn, Nanjing 210096, Peoples R China
[2] Hunan Univ Technol, Hunan Key Lab Green Packaging & Applicat Biol Nan, Zhuzhou 412007, Peoples R China
基金
中国国家自然科学基金;
关键词
Porous pseudo-carbon paste electrode; Tannic acid; Specific surface area; Anodic stripping voltammetry;
D O I
10.1016/j.elecom.2008.08.044
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A novel and sensitive electrochemical sensor based on porous pseudo-carbon paste electrode (PPCPE) for tannic acid detection is described. PPCPE is fabricated by mixing calcium carbonate microspheres as the template, graphite powders as the filler, and pyrrole as the precursor of polymer which actually acted as the paste. After the polymerization of pyrrole catalyzed by Fe3+, the template calcium carbonate microspheres are removed with 0.1 M hydrochloric acid to form PPCPE. The diameters of these pores are in the range from 2 to 5 gm by SEM observations and the specific surface area of PPCPE is 59.26 m(2)/g by the Brunauer-Emmet-Teller (BET) method. A linear relationship between the anodic stripping peak current and the concentration of tannic acid from 0.02 to 1 mu M and a limit of detection as low as 0.01 mu M are obtained using PPCPE. (C) 2008 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:1657 / 1660
页数:4
相关论文
共 50 条
  • [1] Anodic adsorptive stripping voltammetry at a carbon paste electrode for determination of trace thorium
    Liu, SM
    Li, JN
    Mao, X
    Gao, P
    ANALYTICAL LETTERS, 2003, 36 (07) : 1381 - 1392
  • [2] Anodic Stripping Voltammetry or Detection of DNA Hybridization with Porous Pseudo-Carbon Paste Electrode by Gold Nanoparticle-Catalyzed Silver Enhancement
    Xu, Lijian
    Du, Jingjing
    He, Nongyue
    Deng, Yan
    Li, Song
    Wang, Ting
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2009, 9 (04) : 2698 - 2703
  • [3] Determination of trace amount of bismuth(III) by adsorptive anodic stripping voltammetry at carbon paste electrode
    Guo, HS
    Li, YH
    Xiao, PF
    He, NY
    ANALYTICA CHIMICA ACTA, 2005, 534 (01) : 143 - 147
  • [4] Catalytic adsorptive stripping voltammetry at a carbon paste electrode for the determination of amiodarone
    Liu Ning
    Gao Wei
    Song Jun-Feng
    CHINESE JOURNAL OF CHEMISTRY, 2006, 24 (11) : 1657 - 1661
  • [5] Determination of trace vanadium by adsorptive stripping voltammetry at a carbon paste electrode
    Li, Yi-Heng
    Wang, Yue-Xuan
    Huang, Mei-Hua
    ELECTROANALYSIS, 2008, 20 (13) : 1440 - 1444
  • [6] Determination of nickel by anodic adsorptive stripping voltammetry with a cation exchanger-modified carbon paste electrode
    González, P
    Cortínez, VA
    Fontán, CA
    TALANTA, 2002, 58 (04) : 679 - 690
  • [8] Determination of trace tin by anodic stripping voltammetry at a carbon paste electrode
    Li, Yi-Heng
    Xie, Hong-Qi
    Zhou, Fang-Qin
    Guo, Hui-Shi
    ELECTROANALYSIS, 2006, 18 (10) : 976 - 980
  • [9] Trace determination of zirconium(IV) by anodic adsorptive voltammetry at a carbon paste electrode
    Mao, X
    Lai, HX
    Li, JN
    Gao, P
    Yan, ZH
    CHINESE CHEMICAL LETTERS, 2004, 15 (11) : 1315 - 1318
  • [10] Trace determination of vardenafil hydrochloride in commercial formulation and human serum by adsorptive anodic stripping voltammetry at a carbon paste electrode
    Mohamed M. Ghoneim
    Amera M. Hassanein
    Nehal A. Salahuddin
    Hanaa S. El-Desoky
    Mona N. Elfiky
    Journal of Solid State Electrochemistry, 2013, 17 : 1891 - 1902